- 10 -
Figure 6
Distribution Box
4. Network Connection: The Ethernet connection at JP1 is an RJ-45 style jack. A 10 foot
Ethernet Cat 5 crossover cable is supplied with the unit.
B.
Distribution Box (see Figure 6)
1. Connect the RS-485 wires (blue, white and shield) and 24Vdc power (red and black) from
the main processor unit.
2. Install ½” liquid-tight conduit between the distribution enclosure and the probes unless ½”
rigid conduit is used for long distance runs. Use a minimum of 6 feet of liquid tight at the
probes.
3. The probe connector comes with an adapter which allows the attachment of the ½” flexible
conduit connector.
4. Connect the probes to the distribution enclosure using the manufacturer supplied four
conductor shielded cable. Probe cable connections are shown in Figure 6.
5. Optional - Connect the transmitter box to the distribution box using a RS-485 cable.