NOTE:
If you press button, the remote led indicators will show the latest parameters which
were sent.
DISP
-1-
-2-
BRIGHTNESS
HOLD TIME
DAYLIGHT
SENSOR
STAND-BY DIM
STAND-BY TIME
High end trim turning function(To
Set the output level of connected
lighting during occupancy)
To represents the time that the
Sensor will keep the light at low dim
level after the HOLD TIME elapsed.
To represents various thresholds of
natural light level for the Sensor .
The daylight sensor stops working,
and all motion detected could turn on
the lighting fixture, no matter how
bright the natural light is.
LED
DESCRIPTION
DESCRIPTION
The time that the Sensor will turn
off(if you choose stand-by level is
0) or dim the light to a low level
after the area is vacated
SENSITIVITY
To set the occupancy sensing
sensitivity of the Sensor
LED
To set the output level of connected
lighting during vacancy. The sensor
will regulate the lighting output at
the set level. Setting the STAND-BY
DIM level at 0 means light full off
duringvacancy.
To select the current surrounding lux
value as the daylight threshold. This
feature enables the fixture to function
well in any real application
circumstances.
LED INDICATORS
Power
supply
Carrying case
Upload
range
Op
.
temperature
Dimensions
2
x
AAA
1
.
5V
battery
,
Alkaline
preferred
RC-100 in carrying case
Up
to
15
m
(50
ft
.
)
0°C~50°C (32°F~122°F)
123
x
70
x
20.3
mm
(
4
.
84
"
x
2.76
"
x
0
.
8
"
)
INT
-
REMOTE
Sensor
Remote
Programmer
OPERATION
INSTRUCTIONS
SPECIFICATIONS
Remove
the
batteries
from
compartment
if
the
remote
will
not
be
used
in
30
days
.
WARNING
OVERVIEW
The
Wireless IR Configuration Tool is a handheld tool for remote configuration of
remote control
IR-enabled fixture integrated sensors. The tool enables device to modify via pushbutton without
ladders or tools, and stores up to four sensor parameter modes to speed configuration of multiple
sensors.
The
uses bidirectional IR communication to send and receive sensor settings at
remote control
mounting height up to 50 feet. The device can display previously established sensor parameters,
copy parameters and send new parameters or store parameter profiles. For projects where identical
settings may be desired across a large number of areas or spaces, this capability provides a
streamlined method of configuration. Settings can be copied throughout a site, or in different sites.
with carrying case
REMOTE
500
300
100
50
30
10
MODE4
MODE3
MODE2
MODE1
DAYLIGHT
SENSOR
BUTTON OPERATION
Press button, all settings go
back to settings of dip Switch in
sensor.
ON/
OFF
Press button, upload the
current parameters to sensor(s),
the led light which the sensor
connects will
on/off as confirm.
SEND
OK
Press button, the sensor starts to
function and all settings remain the same
as the latest status before the light is
switched on/off.
AUTO
Enter in the setting condition, the
parameter leds of remote control will
flash to be selected. and Navigate to
UP and Down for choose selected
parameters in LED indicators.
The button is for testing purpose
sensitivity only. after you choose sensitivity
thresholds, then you press button,
The sensor goes to test mode(hold time is
only 2s) automatically ,meanwhile the
stand-by period and daylight sensor are
disabled. Press button to quit from
this mode.
TEST
2s
BUTTON
DESCRIPTION
BUTTON
DESCRIPTION
RESET
DISP
Display the current/lastest setting
parameters in LED indicators(the
LED indicators will on for showing
the setting parameters).
4 Scene modes with preset
parameters which are available to
be changed and saved in modes.
MODE1
MODE2
MODE3
MODE4
Navigate to LEFT and RIGHT for
choose selected parameters in
LED indicators.
SETTING
The SETTING Content contains all available settings and parameters for remote sensors. It
allows you to change the available control, parameters, and operation of the sensor from
factory default or current parameters.
Change multiple settings of sensor(s)
1.Press button, the remote control leds will show the latest parameters you set.
Confirm the selected parameters
selected parameters in remote
control.
Open and close smart daylight Sensor.
Press or Enter in the setting
condition, the parameter leds of remote
control will flash to be selected, Press
for open or close smart daylight
Sensor.
DISP
SEND
TEST
2s
TEST
2s
AUTO
NOTE:
the setting works key step is by Push or
,
enter in the setting condition.
NOTE:
the led light which the sensor connects will on/off after getting the new parameter as confirm.
RESET
Press the button, the light goes
to permanent on or permanent off
mode, and the sensor is disabled.
(MUST press button to quit this
mode for Setting.
AUTO
ON/
OFF
AUTO
ON/
OFF
AUTO
NOTE:
if you push button before, you must push button to unlock the sensor.
2.Press or enter in the setting condition, the parameter leds of remote control will flash to be
selected, navigate to the desired setting by pressing
to select the new parameters.
3.Press ok to confirm all setting and saving.
4.Aim at the target sensor and press to upload the new parameter, the led light which the sensor
connects will on/off as confirm.