3.2.3 Connecting the gas cartridge
The following gas cartridge types may be used:
• CV 360 (about 30 min. flame duration)
• CP 250 (about 200 min. flame duration)
• CV 300 Plus (about 180 min. flame duration)
• CV 470 (about 400 min. flame duration)
• EXPRESS 444 (about 35 min. flame duration).
The gas cartridges can be purchased from a local dealer.
W
ARNING
For operation with a gas cartridge, the P60 nozzle must be inserted in the
device and the gas cartridge adapter must be installed. Gas cartridges may
only be used at an ambient temperature of 15-35 ºC (see note in the cartridge
instructions).
The connection of the CP 250, CV 300 Plus/CV 470 and EXPRESS 444
cartridges is described in the enclosed instructions. The CV 360 gas cartridge
is connected as follows:
The gas cartridge is now open and ready for use.
The flame can now be ignited using any of the three operating modes.
Verify that the gas cartridge adapter
is inserted and has audibly clicked
into position.
Ensure that the smooth side of the cap (1)
points toward the device.
Turn the milled knob on the cartridge adapter
fully clockwise in the "OFF" direction.
Insert the gas cartridge into the cap until it
audibly clicks into position.
Then open the gas cartridge adapter:
Turn the milled knob fully counterclockwise in
the "ON" direction.
1