Connection Example Diagrams. 

The following diagram shows how the inputs and outputs are connected to the 2300-MULTI station. 

Section D:  Dip Switch Settings. 

DIP SWITCH 

FUNCTION  

DESCRIPTION 

   

STATION ID     +1 

Station 

ID’s from 0 to 127 are set up using switches 1 to 7  

   

STATION ID     +2 

“ 

   

STATION ID     +4 

“ 

   

STATION ID     +8 

“ 

   

STATION ID     +16 

“ 

   

STATION ID     +32 

“ 

   

STATION ID     +64 

“ 

  -  Not 

used 

 

  -  Not 

used 

10 

   

BAUD RATE 

 

For MicroScan use DIP Switch 10 

ON

 (Factory default) 

Power and RS485 Comms Wiring. 

Warning:

 If the power/communication connections are reversed, the remote station may become faulty. 

2300-MULTI Station Number Programming and Serial Number. 

Important:

 When commissioning remote stations, you must programme a unique station number before using the programme 

setup button in the Scada Software. Requires MicroScan Version 5.0 onwards. 

 

1. 

Close the MicroScan Scada down and turn the power off to the 2300 485 converter. Connect the new Remote  

 

Station, referring to ‘

Wiring and Installation

’ and ‘

Commissioning

’ 

2.   

Turn power back on to the 2300 485 converter, and start MicroScan, under Setup Tools select Add  New Station 

3.   

Select ‘Page and Line Settings’, or ‘Tag Setup’ and configure as per the MicroScan help file. 

Important Note: 
If using the USB485 converter, do not connect to the computer until after MicroScan has been installed. 

 

MODBUS Applications: 

If using the 2300-MULTI station in other applications where 

MODBUS 

is required, please refer to the  

2300-MULTI MODBUS supplementary manual 

which is available for download from the Intech website: 

www.intech.co.nz/2300

 

1

3

4

2

-    12Vdc @ 115mA

Pin

Connection

+   24Vdc @ 58mA

+   Comms

-    RS485

70 

71 

81 

82 

Notes: 

1.  Logic power input (terminals 17 & 18) range 
12~24Vdc.  The logic power supply input must be 
isolated and completely separate to the power  
supply that powers the 2300-MULTI on terminals 81 
& 82.  Failure to do so will cause the comms to stop. 
2.  Terminals 5, 9, 18 are internally connected and 
are common for AI, AO RTD and Logic power input.  
Terminal 14 DC (Digital Common) is isolated - refer  
to Note 5. 
3.  RTD, AI and DI inputs do not require the Logic  
power supply to be connected to terminals 17 & 18. 
4.  AO1 will only work if the Logic power supply is 
connected to terminals 17 & 18.  AO will hold its last 
value until re-written too. 
5.  For DI operation, isolation is possible or for non 
isolated operation DC (terminal 14) can be  
connected to terminal 18 and used with the Logic 
power supply.  For DO operation the Logic power 
supply is required and terminal 14 must be  
connected to terminal 18.  If using DO and DI,  
isolation is not possible. 

RTD Input 1a

RTD  

1b

Input

RTD Input 2a

RTD  

2c

Input

Common/0V

Analog  

 1

Input

Analog Input 2

Analog Out

 1

put

Common/0V

Digital  

1

Input

Digital Input 2

Digital  

3

Input

Digital Input 4

Digital  

Common

Input

Digital Output 1

Digital Output 2

RTD

3 Wire

 +V

Common/0V

 +24Vdc

 0Vdc

 +24Vdc

 0Vdc

 0Vdc

 +24Vdc

or

+24Vdc

RELAY

+

-

+24Vdc

 +

Two Wire Transmitter

0(4)-20mA

 -

Analog Load

0 - 20mA

or

0 - 10V

+

-

0Vdc

 

2300-MULTI

 

(Power supply for input logic section) 

Содержание 2300-MULTI

Страница 1: ...ons Communications between the computer running MicroScan V5 and the 2300 series stations is RS485 1 pair cable multi drop as standard with an option for TCP A 32bit ARM CPU is used in the 2300 series stations to provide high speed data processing and fast communications turn around times All 2300 series stations have been equipped with status led s which are used to indicate the status of the Inp...

Страница 2: ... 70 71 70 71 2300 I O Remote Station 2300 I O Remote Station 2300 I O Remote Station COM TX TX 74 71 USB USB 70 COM TX TX 74 71 70 2100 IS NS RS485 Converter Isolator MicroScan V5 RS232 RS232 2300 I O Remote Station 70 71 RS485 DATA HI WAY CABLE POLARITY MUST BE OBSERVED RS485 DATA HI WAY CABLE POLARITY MUST BE OBSERVED Resistor 1k End of Data Hi way Junction Box IMPORTANT i All cables must be scr...

Страница 3: ...he 2300 MULTI has no user serviceable parts Protective enclosure only to be opened by qualified personnel Remove ALL power sources before removing protective cover 1 1 Factory Configurations The Intech Micro 2300 series I O Remote Stations are factory configured to connect directly to MicroScan V5 software Only the Station number station ID needs to be set via the easily accessible dip switches No...

Страница 4: ...ut Points 2 Maximum Voltage 36 Vdc Maximum Current 100 mA per output Vceon 1 1V Max Isolation Between field and logic 1500Vrms between field and logic Connectors Logic Power and Comms 4 Pin plug in connector on side of station Inputs 18 Way screw plug in connector on top of station Comms Protocols RS485 Modbus RTU Baud Rate 9600 Format 8 bit No Parity 1 Stop Power Supply Logic Supply Voltage 12 24...

Страница 5: ...N OFF ON OFF 44 OFF OFF ON ON OFF ON OFF 45 ON OFF ON ON OFF ON OFF 46 OFF ON ON ON OFF ON OFF 47 ON ON ON ON OFF ON OFF 48 OFF OFF OFF OFF ON ON OFF 49 ON OFF OFF OFF ON ON OFF 50 OFF ON OFF OFF ON ON OFF STATION ID DIP SWITCH SETTINGS SW1 SW2 SW3 SW4 SW5 SW6 SW7 51 ON ON OFF OFF ON ON OFF 52 OFF OFF ON OFF ON ON OFF 53 ON OFF ON OFF ON ON OFF 54 OFF ON ON OFF ON ON OFF 55 ON ON ON OFF ON ON OFF ...

Страница 6: ...ON OFF OFF ON ON ON ON 122 OFF ON OFF ON ON ON ON 123 ON ON OFF ON ON ON ON 124 OFF OFF ON ON ON ON ON 125 ON OFF ON ON ON ON ON 126 OFF ON ON ON ON ON ON 127 ON ON ON ON ON ON ON RS485 Tx RS485 Rx Power Switch 1 Switch 10 2300 MULTI Dimensions The 2300 MULTI enclosure is shown below The station clips directly onto an industry standard DIN rail Field wiring is on the top of the station via a separ...

Страница 7: ... where MODBUS is required please refer to the 2300 MULTI MODBUS supplementary manual which is available for download from the Intech website www intech co nz 2300 1 3 4 2 12Vdc 115mA Pin Connection 24Vdc 58mA Comms RS485 70 71 81 82 Notes 1 Logic power input terminals 17 18 range 12 24Vdc The logic power supply input must be isolated and completely separate to the power supply that powers the 2300...

Страница 8: ... between wires of a pair 50 F m Capacitance between each wire to all others bunched together 95 F m Cross talk between pairs 1kHz 100kHz 90dB 100m 50dB 100m Characteristic Impedance 100kHz 135 Attenuation of a pair 1kHz 10kHz 100kHz 50kHz 1MHz 1 5MHz 0 15dB 100m 0 42dB 100m 0 8dB 100m 0 9dB 100m 1 9dB 100m 2 4dB 100m NOTE All cables are to be subject during manufacture to in process spark testing ...

Отзывы: