background image

© Intatec Ltd 2015

9

Maintenance

Cleaning

   

ATTENTION

: Turn of the water supply at the ball valve before removing the filter.

    Some supplies can contain particles and impurities which could damage the solenoid valve.
    As part of package, a water supply filter is included which must be kept clean to ensure
    maximum water flow.
    Clean the filter by washing thoroughly using running water. 

Battery Replacement

   

When the battery is exhausted, the LED flashes continuously and the solenoid valve stops in the

   closed position. 
   Remove the exhausted battery and repeat the operations described in the section “Activating” 
   in order to re-store the operation of the tap.

Trouble Shooting

   The following details are supplied for on site queries, should further assistance be required our 
   Technical Department can be contacted directly on 01889 272199

Fault

Cause

Solution

No water flow

The isolation valves are closed

Open the isolation valves

Exhausted battery (LED flashes)

Replace the battery

Electrical problem

Check the voltage
Disconnect and reconnect the battery (where
applicable)
Check the connections and the cable’s
integrity
Damaged sensor: ask for assistance

Dirty sensor

Clean the sensor window

Filters are dirty

Close the isolation valves and clean the
filters

Blocked solenoid valve

Ask for assistance

The water flows for 1
minute (without
any object in front of the
sensor), finally stops

Dirty Sensor

Clean the sensor window

Light reflection on the sensor

Remove the reflective surface

Electronic problem

Disconnect and reconnect the battery 

The water flows for more
than 1 minute

Blocked solenoid valve /
damaged sensor

Ask for assistance

Содержание IR180CP.1

Страница 1: ...urate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel 01889 272 180 Fax 01889 272 181 email sales intatec co uk web www intatec co uk Intatec Ltd 2015 ...

Страница 2: ...8 472 791 Products Infra Red Basin Tap IR180CP 1 Check Content Before commencing remove all components from packaging and check each component with the contents list Ensure all parts are present before discarding any packaging If any parts are missing do not attempt to install your Inta shower valve until the missing parts have been obtained Technical Data Operating water pressure range 1 to 8 bar...

Страница 3: ... Intatec Ltd 2015 2 Dimensions 108 56 G 119 137 60 40 5 39 70 ...

Страница 4: ...3 Item Qty Component Item Qty Component 1 1 Tap 5 2 Stainless steel flexible hose 2 1 Fixing kit 6 2 Inlet nut 3 1 Battery box 7 2 Sealing washer 4 2 Wall plug and fixing screw 8 1 Power cable Components 2 5 7 6 8 3 4 1 ...

Страница 5: ... Flush the water supply pipes thoroughly prior to installation Do not allow debris PTFE tape or any metal particles to enter the tap Turn off the water supply Important All plumbing to be installed in accordance with applicable codes and regulations Installation FAILURE TO OBSERVE THE INSTALLATION INSTRUCTIONS WILL INVALIDATE THE PRODUCT WARRANTY CONDITION 1 Screw the flexible hoses 5 into the inl...

Страница 6: ...d This new setting will be stored in case of battery replacement or lacking of electricity Safety Device To prevent flooding of the premises following an act of vandalism or misuse an object left in front of the sensor or a dirty sensor the tap has a safety device that shuts off the water flow after about one minute Once the object has been removed or the sensor has been cleaned the tap starts wor...

Страница 7: ...queries should further assistance be required our Technical Department can be contacted directly on 01889 272199 Fault Cause Solution No water flow The isolation valves are closed Open the isolation valves Exhausted battery LED flashes Replace the battery Electrical problem Check the voltage Disconnect and reconnect the battery where applicable Check the connections and the cable s integrity Damag...

Страница 8: ... at its option to repair or replace any faults caused by defective material or manufacturing that may arise see Intatec Warranty The warranty does not cover dame caused by Abnormal or improper use Incorrect installation or water system problems Normal wear or negligence in maintenance and in use Acts of vandalism Contact with abrasives corrosive chemicals or unsuitable cleaning agents or instrumen...

Отзывы: