Flow Control Valve Replacement

Isolate both the hot and cold water supplies

Remove the cover and unscrew the control knob retaining screw and remove the flow control knob. 
Using a suitable spanner unscrew the flow control valve.  

Replace with a new valve or replace the disk washer as required and assemble in the reverse order.

Cartridge Replacement

Isolate both the hot and cold water supplies.

Remove the cover and unscrew the control knob retaining screw and remove the temperature control knob.

Carefully pull the cartridge out of the body

If any of the ‘O’ ring seals or the thermostatic element is blocked or damaged they must be replaced.

Using neutral silicon grease re-lubricate the internal moving components of the valve.

Re-assemble in the reverse order.

The valve must then be re-commissioned following the procedure detailed.

Operation

The red button on the temperature control knob locks the mixed water temperature to 38˚C, press the 
button to release the knob to increase the or lower the water temperature.

Turning the flow control knob anti-clockwise turns on the water and regulates the amount flowing.

 Components

Cover

Retaining

screw

Flow control

valve

Control

knob

Cover

Retaining

screw

Temperature
control knob

Thermostatic
cartridge

Filter

Non turn

valve

Содержание 10019CP

Страница 1: ...tion as accurate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or...

Страница 2: ...ters and unbalanced supplies i e cold mains tank fed hot They are not suitable for non modulating combination boilers Designated Pressure LP HP Max Static Pressure 10 bar Temperature Stability 2 C Inl...

Страница 3: ...o a solid wall Cut a channel into the wall for the supply pipes allowing sufficient depth to position the concealing plates to as shown on the finished tiled surface Connect the supply pipes to the va...

Страница 4: ...out of the body If any of the O ring seals or the thermostatic element is blocked or damaged they must be replaced Using neutral silicon grease re lubricate the internal moving components of the valve...

Страница 5: ...on is required when the thermostatic shower valve is used in a TMV2 Applications under the requirements of BS EN 1111 1999 Sanitary tapware Thermostatic Mixing Valve PN 10 General Technical Specificat...

Страница 6: ...nstaller of the thermostatic shower valve must comply with the requirements of the Water supply Water Fittings Regulations 1999 and also be aware of their responsibility and duty of care to ensure tha...

Страница 7: ...s and strainers 9 The fitting of isolation valves is required as close as is practicable to the water supply inlets of the thermostatic shower valve 10 The fitting of strainers is recommended as close...

Страница 8: ...are met proceed to set the temperature as stipulated in the manufacturer s installation instructions 4 3 Measure and record the temperature of the hot and cold water supplies at the connection to the...

Страница 9: ...no significant change to the set outlet temperature 2 C or less from the original settings and the fail safe shut off is functioning then the valve is working correctly and no further service work is...