INSYS Modem 336 LL 2D/4D 5.x Originate / Answer
S Registers
S31*
General settings
Bit Meaning
Bit 0
Reserved
Bit 1
Description
Connect message
0: 3 line message (
\V0
)
1: Expanded 1-line message (
\V1
)
Bit 2-3
Error correction
Messages
Messages:
0: Only PC baud rate
1: PC and phone baud rate
(
ATW1
)
2: Only phone baud rate
(
ATW2
)
Bit 4-7
Reserved
S36*
Reset of error logs
Bit Meaning
Bit 0..2
Determines what happens
if an attempt to establish a
V.42 LAP-M connection
fails. It is connected to the
register S48.
0
The modem hangs up.
1.
The modem stays online and establishes a direct
mode connection.
2 Reserved
3
Modem stays online and establishes a normal
mode connection.
4
Modem attempts to establish a MNP connec-
tion. In case of failure it hangs up.
5
Modem attempts to establish a MNP connec-
tion. In case of failure a direct mode connection
is established.
6 Reserved
7
Modem attempts to establish a MNP connec-
tion. In case of failure a normal mode connec-
tion is established.
Bit 3.0.5
SMS type
0:
normal fixed network modem
(
AT*M0
)
1:
D1 and E networks
(
AT*M1
)
4: D2
network
(
AT*M4
)
5: Fax
(
AT*M5
)
6:
Fixed network SMS
(
AT*M6
)
Bit 6
Key abort
0:
Key abort activated
(
AT%B0
)
1:
Key abort deactivated
(
AT%B1
)
Bit 7
Call acceptance
1:
Call answer not locked
(
AT*A1
)
0:
Call answer locked
(
AT*A0
)
S38
Time period until forced hang up
Maximum time in seconds left for the buffers to empty their data after a com-
mand to hang up has been received. Only applies to error corrected connections.
75
Содержание Modem 336 LL 2D/4D 5.x Originate / Answer
Страница 1: ...Manual INSYS Modem 336 LL 2D 4D 5 x Originate Answer INSYS Modem 336 Leased Line Apr 10...
Страница 2: ......
Страница 80: ......