S Registers
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer
Tabs Function
Units Range
Default
S29
Time period for modifier “flash”
10 ms
0-17
0
S30
Time period until hang up due to silence
10 s
0-255
0
S31* General
settings
-
192
S36*
Reset of error logs
-
135
S38
Time period until forced hang up
s
0-255
20
S39* Flow
control
-
3
S40* General
settings
-
104
S41* General
settings
-
195
S46* Data
Compression
-
138
S48*
Setting for V42 negotiation phase
-
7
S86 Error
event
code
-
Read-only
S91* Transmit
Level
-
6-15 15
S95* Result
code
-
0
Table 13: Overview S Registers: Units, value range, presets
17.2
Description S Registers
Note:
Registers marked with *) are stored in the user defaults with the command
AT&W.
S0*
Number of ringing tones until automatically going off-hook
Number of rings until the modem goes off-hook
For S0=0 the modem will not go off-hook when a call comes in. The value of S0
can be between 0 and 5.
S1
Ringing tone counter
Counter for call ringing. S1 is read-only. S1 will be reset to zero, when the modem
answers a call.
S2*
Escape
Escape character which causes a switch from data mode to online command input
mode. Values larger than 127 will result in no ESC character being recognized.
S3
Return
Carriage Return Character (CR).
S3
Linefeed character
Linefeed character
S5
Backspace character
Backspace character
70
Содержание Modem 336 LL 2D/4D 5.x Originate / Answer
Страница 1: ...Manual INSYS Modem 336 LL 2D 4D 5 x Originate Answer INSYS Modem 336 Leased Line Apr 10...
Страница 2: ......
Страница 80: ......