Functions
INSYS Modem 56k small EU 2.1
38
12.8
Automatic Dial-Up Delay
The standard TBR21 applies to all public phone networks in EC countries (Belgium, Den-
mark, German, Finland, France, Greece, Great Britain, Ireland, Italy, Luxembourg, Nether-
lands, Austria, Portugal, Sweden, Spain), as well as in Switzerland, Liechtenstein, Norway
and Iceland.
According to the regulations of the TBR 21, a dial-up is blocked for 2 hours after 12 un-
successful dial-up attempts.
In this case, the modem indicates the message
BLACKLISTED
.
The modem must be briefly disconnected from the power supply in this case.
The counter will be reset automatically following each successful connection establish-
ment.
If the connection to the remote terminal has been established successful, a dialling pau-
se of 5 seconds will be maintained.