Functions
INSYS Modem 56k small EU 2.1
32
12.2.2
Phone Connection
The automatic negotiation of the baud rate and the modulation standard enables the
INSYS Modem 56k small EU 2.1 to negotiate the largest possible connection speed to the
remote terminal while the connection is established. The speed depends on the settings
and the abilities of the modem at the remote terminal. Via the modulation standard, the
connection speed can be set through the phone line. If nothing is defined, the INSYS Mo-
dem 56k small EU 2.1 will automatically try to determine the optimum connection pa-
rameters.
The function is active as default.
Configuration with HSComm
A direct configuration with the HSComm is not intended. The AT command to
define a fixed baud rate can be sent to the INSYS Modem 56k small EU 2.1 via
the entry field "Initialization string" (page 26, Figure 5, position 13).
Configuration with AT commands
To configure the modulation standard and
thus the connection speed, use the command:
AT+MS=<modulation>
Please find the possible parameters for this command in the Chapter "AT
Command reference".
To display the current settings:
AT+MS?
For a list of possible parameter of the com-
mand, enter:
AT+MS=?