Chapter: Run tests
80
M16-16905-EN
images for DIC Replay. In this case, specimen preparation is easier as you only
require the speckle pattern and you do not need to apply any dots.
If you choose Speckle only, note the following:
•
Do not create a measurement based on AVE2.
•
Do not set the AVE2 as the strain source for the test method.
•
Do not enable auto-balance on the AVE2.
To use DIC Replay software to analyze images
1. Select
in the console area to open System Details.
2. Select the video extensometer icon under System Settings to open the Transducer
Settings dialog for a video extensometer.
The dialog opens in the AVE2 screen.
3. Select Image Capture.
The dialog moves to the Image Capture screen.
4. Select Open Digital Image Correlation software....
Using Bluehill
®
3
Once calibrated, the video extensometer behaves like any other transducer when you
operate it with Bluehill
®
3 software. For full details, refer to the Bluehill
®
online help and
reference. A summary of possible setup steps using Bluehill
®
3 software and an AVE2 is
as follows:
1. Go to Measurements > Setup and create a physical strain measurement using Strain
1 as the transducer configuration. The video extensometer is always connected to
Strain 1. You can name the measurement AVE2.
2. Go to Test Control > Strain and choose the new AVE2 measurement as the primary
source.
3. Go to Test Control > Pre-Test and enable auto-balance for the AVE2.
4. Setup the workspace to your requirements. You will probably want to assign one of
the live displays to show AVE2 strain.
Using Bluehill
®
3 software with DIC Replay
For full details, refer to the manual supplied with DIC Replay software.
DIC Replay is not available for the SVE2 extensometer.
Содержание AVE2
Страница 1: ...Instron Video Extensometer AVE2 and SVE2 Operator s Guide M16 16905 EN Revision D...
Страница 8: ...Preliminary Pages 8 M16 16905 EN...
Страница 11: ...11 Preliminary Pages Product Support www instron com Chapter 10 Maintenance 83 General 83 Index 85...
Страница 12: ...Preliminary Pages 12 M16 16905 EN...
Страница 16: ...Chapter Introduction 16 M16 16905 EN...
Страница 24: ...Chapter Specifications 24 M16 16905 EN...
Страница 34: ...Chapter Installation 34 M16 16905 EN Figure 9 AVE2 on a 5940 single column testing machine A...
Страница 46: ...Chapter Installation 46 M16 16905 EN Figure 21 AVE2 on an 8801 series testing machine...
Страница 49: ...49 System interconnections Product Support www instron com Figure 23 Video extensometer connectors 6 1 3 2...
Страница 50: ...Chapter Installation 50 M16 16905 EN...
Страница 76: ...Chapter Set up other software not Bluehill 76 M16 16905 EN...
Страница 84: ...Chapter Maintenance 84 M16 16905 EN...
Страница 87: ......
Страница 88: ...www instron com...