Quick start guide

AUTOMATED EXTERNAL DEFIBRILLATOR

WITH MANUAL FUNCTION

Содержание Eazy

Страница 1: ...Quick start guide AUTOMATED EXTERNAL DEFIBRILLATOR WITH MANUAL FUNCTION ...

Страница 2: ...terations made in the device attempts of repair not provided by authorized technical assistance centers operation by unqualified personnel use of defective device or use of accessories and parts not supplied by the manufacturer For information about warranty or technical assistance please contact Instramed s technical support Copyright 2017 Instramed The Eazy PRO Instramed and its respective logos...

Страница 3: ...rrent Attention occasional use Even when disconnected stand by the Eazy PRO executes internal routines checking the status of the equipment In spite of this procedure entailing a low power consumption the battery charge may be consumed Therefore whenever the device has not been connected to an electric current for more than 20 days it is advisable to execute a full battery charge If this procedure...

Страница 4: ...pretation 07 Warnings 08 Adverse effects 08 Precautions 09 Electromagnetic Compatibility 09 The Equipment 10 Front panel 10 Sides 10 Function of the front panel elements 11 1 Touch screen 11 2 Operational status indicator 13 3 Start button 14 Operating in AED mode 15 Operating in manual mode 16 Adhesive pads placement 17 1 adults 17 ...

Страница 5: ... 19 ECG Monitoring 21 CPR Maestro 22 Using the CPR Maestro 22 PC Connection 23 Requirements 23 SoftDEA Installation 23 Connecting the Eazy PRO to a PC 23 Inspection and Maintenance 24 Device care 24 Cleaning and disinfection 24 Preventive Maintenance 24 Corrective Maintenance 24 Warranty Certificate 25 ...

Страница 6: ...lent contrast and visualization area the user selects the operation mode and charge while visualizing the ECG curve The interface is simple and self explanatory Characteristics Semi automated Artificial Intelligence accurate diagnosis of the patient s conditions indicating shock delivery or not Safety precautions prevents accidental use in cases in which shock treatment is not advisable or in heal...

Страница 7: ...ommended for children under one year old Pacemakers may affect the device s efficiency Medicines in adhesive form must be removed before starting defibrillation Hypothermic patients may not respond well to defibrillation Once the removal of the patient is started the defibrillation must be interrupted Qualified users Shall be considered qualified users those who have had training in a recognized i...

Страница 8: ...chnical assistance centers NOTICE the use of the Eazy PRO is restricted to one patient at a time NOTICE the applied parts are protected against defibrillation discharge during discharge there may be baseline variation NOTICE avoid connecting the patient to several items of equipment at the same time The limits of current leakage may be exceeded NOTICE the applied parts intended to come into contac...

Страница 9: ...as electrosurgical equipment and computer tomography CT WARNING Using the Eazy PRO requires special precautions concerning Electromagnetic Compatibility in compliance with the information contained in this manual Mobile and portable RF communications equipment such as a cellphones may affect the functioning of the Eazy PRO Maximum length of accessory cables in order to comply with the requirements...

Страница 10: ...teraction with the device 2 Operational status indicator 3 Start button AUTOMATED EXTERNAL DEFIBRILLATOR AED MANUAL OVERRIDE FUNCTION 1 Speaker 2 Battery power supply con nector 3 Battery compartment 4 USB connector 5 Disposable pads compart ment 6 Disposable pads connector 7 Cabinet recess 2 2 3 3 4 5 7 6 1 1 ...

Страница 11: ...sents the following items on the screen when connected to the patient Analyzing Do not touch the patient CPR 00 00 BPM 080 1 2 3 4 5 6 7 1 Heart beats per minute 2 Manual mode button 3 Orientation message 4 ECG curve 5 CPR interval counter counts the interval between discharge delivery helping in the CPR Cardiopulmonary resuscitation massage 6 Battery status 7 Icon indicating the defibrillation st...

Страница 12: ...arging delivering the shock and CPR interval counting will be the user s entire responsibility Charge Charge Cancel CPR 00 00 BPM 080 1 3 6 7 5 8 9 4 2 1 Heart beats per minute 2 Charge selector allows the user to select the desired energy charge in joules 3 Selected charge 4 ECG curve 5 Automatic mode button 6 Charge button charges the defibrillator to the selected energy setting 7 CPR interval c...

Страница 13: ... assistance Mains supply Led on means device is connected to the electric current Mains supply Led blinking when in normal use means the battery needs charging Battery Led on means internal battery is being charged A blinking Led beside this symbol means full charge EVEN WHEN THE BATTERY HAS BEEN FULLY CHARGED THE OPERA TIONAL STATUS INDICATOR WILL STILL BE SHOWING The display will only change fro...

Страница 14: ...the patient indicates the need for it NOTE it is not necessary to switch the Eazy PRO off Fifteen seconds after the removal of pads from the patient or disconnection of pads from the equipment the device switches itself off saving battery charge In this moment the follow ing message will be heard The device is being turned off Press the button in order to turn the machine back on More information ...

Страница 15: ...ipment The energy delivered is preset The user cannot change this protocol For adult electrodes 1st shock 150J the following 200J For child electrodes 50 J More information on this topic is available in the Eazy PRO User Manual present on the CD which accompanies the product Start Início 3 2 4 1 5 6 Shock delivered start CPR cardiopulmonary resuscitation Equipment analyzes patient s condition Plac...

Страница 16: ...the mode change the Eazy PRO ceases to emit sound and visual orientation in addition to the automatic safeguards against shocks Press button to start cycle Press button to deliver shock Place pads on patient Shock delivered Start CPR Cardiopulmonary Resuscitation Activate manual mode Select charge and charge energy ATTENTION The use of the manual mode is the user s entire responsibil ity The use b...

Страница 17: ...st be dry ATTENTION The presence of too much hair in the contact area may affect scanning In this case shave hair ATTENTION The pads must be applied directly over the skin DO NOT place pads over clothes ATTENTION The pads are disposable and for single use cannot be reused under any circumstances ATTENTION After opening the wrapping the pads should be used within 24 hours ATTENTION In case of use f...

Страница 18: ...f age to eight years of age or patients who weigh less than 25kg some precautions must be taken Use child pads If the pads cannot be placed within the minimal distance of 4 centimeters between them place one of them on the child s chest and another on his back More information on this topic is available in the Eazy PRO User Manual present on the CD which accompanies the product 2 ...

Страница 19: ...e cycle CPR for 2 minutes No pulse no breathing recovery Shock recommended Shock delivered Check patient s condition Place victim on a dry flat and steady area The Eazy PRO analyzes patient s condition Shock NOT recommended Move away from the patient Activate AED CPR for 2 minutes Wait for emergency team Wait for emergency team Place pads Activate the Eazy PRO Simplified diagram of procedure in ad...

Страница 20: ...area Place pads Activate the Eazy PRO The Eazy PRO analyzes patient s condition Shock NOT recommended CPR for 2 minutes It doesn t recover breath and or movements Shock recommended Move away from the patient Activate AED Shock applied CPR for 2 minutes Wait for emergency team Wait for emergency team Wait for emergency team Conscious Panting It recovers breath and or movements Simplified diagram of...

Страница 21: ...ated defibrillator using the AHA protocol ECG cable and adhesive pads connected the device will give priority to the adhesive pads utilization operating as an external automated defibrillato using the AHA protocol Only ECG cable connected the equipment monitors the patient s ECG silently always on DII derivation and alarms when detects a situation of cardiac arrest In this situation and in shock i...

Страница 22: ...s The parameter will be automatically turned off on the Eazy PRO screen 1 Connect the CPR Maestro to Eazy PRO using the input indicated below located on the side of the equipment 2 Place the device on the patient s chest according to the image below This step is important and must always be followed When the equipment is initialized the CPR sensors are calibrated enabling the evaluation of the com...

Страница 23: ...uctions which will show up on the screen Connecting the Eazy PRO to a PC Connect the equipment only after installing SoftDEA After the installation connect the device through the USB cable given The location of the device drivers to be installed will be required They can be found in this folder C Program Files Instramed SoftDEA DRIVERS Start the SoftDEA application On the language selection screen...

Страница 24: ...ral soap or isopropyl alcohol Never immerse the defibrillator in liquids Preventive Maintenance Instramed recommends that the Eazy PRO be examined by a qualified technician every 12 months We recommend that you contact the manufacturer for more information about qualified and trained personnel in your area to perform preventive maintenance It is recommended that periodic inspections be performed o...

Страница 25: ...ion to a power source use distinct from that described in the User manual or irregular working conditions Any attempt to violate adjust or repair this equipment by individuals not authorized by Instramed Indústria Médico Hospitalar Ltda will automatically invalidate this warranty This also applies in case of alterations made to this contract the fiscal receipt or to the equipment s serial number I...

Страница 26: ...www Instramed com br 55 51 3073 8200 AUTOMATED EXTERNAL DEFIBRILLATOR WITH MANUAL FUNCTION ...