Page 13 of 14
2982-222 - Rev: 1/21/2014 8:34 AM
Problem
Possible Cause
Solution
Smoke Bridge can
turn off a Responder,
rather than on.
The responder may be
linked at its off state.
Re-Link the responder to smoke bridge, while the
responder’s load is on. See the Responder’s
Owner’s Manual for more detailed linking
instructions.
When I press Test on
smoke alarm, the
Smoke Bridge
responders are not
turning on.
Using the Set button to
create a link to a
responder links it to the
Smoke Detected group
only.
To link to the test button group, you must use
software or a smart device (iOS or Android) app.
Smoke Bridge is
locked up.
A surge or excessive
noise on the power line
may have glitched it.
Unplug Smoke Bridge for 10 seconds and then
reinstall.
If the above doesn’t work, perform a factory reset.
See
Resetting Smoke Bridge to its Factory Default
Settings
.
If you have tried these solutions, reviewed this Owner’s Manual, and still cannot resolve an issue you are
having with Smoke Bridge, please call:
INSTEON Support Line
866-243-8022