GUARANTEE  

 

Your boiler is guaranteed for two years from date of installation. 
 
Our guarantee  includes on site  labour and parts for problems caused by fault of manufacture and 
component failure with the following exclusions: 
 

1

 

Problems caused by hard water and lime scale. We regret that we cannot be held responsible 
for problems caused by hard water 

 
2

 

Dripping Taps. These components are subject to wear and tear but in the event of a tap failing 
within twelve months of installation, we will be pleased to replace the tap assembly by post. 
Fitting is very simple and requires no tools. An engineer call-out is not necessary.  
 

3

 

Accidental  damage,  misuse  or  use  not  in  accordance  with  these  instructions  and  damage 
caused by incorrect installation.   

 
The manufacturer disclaims any liability for incidental, or consequential damages.   

 

 

 

Содержание Barista Pro WB-2

Страница 1: ... Pro Range MODELS WB 2 WB 2 6KW Auto Fill Catering Steam Water Boiler INSTALLATION AND USER INSTRUCTIONS INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB2 ISS 02 ...

Страница 2: ...ARES SERVICE INFORMATION 7 SERVICE WARNINGS FAULT DIAGNOSTICS 8 GUARANTEE 9 INTRODUCTION Dear Customer Thank you for purchasing this Instanta product Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more...

Страница 3: ...sion or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference PLEASE NOTE These units should be insured and inspected annually ...

Страница 4: ...ese will contaminate the water ELECTRICAL SUPPLY 3 The 3kW model is fitted with a 13amp plug and should be plugged into a suitable socket The 6kW model should be wired into a 30amp switched supply with an ELCB Only a suitable electrician should undertake this work COMMISSIONING 4 Open the steam tap on the left hand side of the unit 5 Switch on using the switch on the front panel The power light wi...

Страница 5: ...l surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet SERVICE WARNINGS AND FAULT DIAGNOSIS Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault conditions Some of these are less serious and...

Страница 6: ...k lime scale or broken probe wire 8 Pressure switch wire has shorted wire A 9 Pressure switch wire has shorted wire B 10 The element s have been trying to heat the water but have failed to do so The element s or control system have failed 11 Water supply is turned off and the low probe has become exposed Probable lime scale build up or water supply problem SERVICE TECHNICAL SUPPORT Tel 01704 50291...

Страница 7: ...ble for problems caused by hard water 2 Dripping Taps These components are subject to wear and tear but in the event of a tap failing within twelve months of installation we will be pleased to replace the tap assembly by post Fitting is very simple and requires no tools An engineer call out is not necessary 3 Accidental damage misuse or use not in accordance with these instructions and damage caus...

Отзывы: