background image

 

TECHNICAL SPECIFICATION 

 

Model 

WB-2 

WB-2/6KW 

Width 

mm 

345 

345 

Depth 

mm 

600 

600 

Height 

mm 

585 

585 

Power Rating 

KW 

3.0 

6.0 

Weight (Empty) 

KG 

23 

23.8 

Weight (Full) 

KG 

28.3 

29.2 

Water Inlet Pressure: 

Bar 

2 to 7 

2 to 7 

 
 

INSTALLATION  

IMPORTANT 

To ensure that the unit works to its full potential, you will require water pressure of at least 30psi (2 
Bar). If this is not possible, a pump should be fitted. 

Having ensured that the incoming water pressure is adequate, follow these simple instructions: 

1.

 

Provide a suitable stop-cock to isolate the machine for maintenance when needed 

2.

 

Connect the water between the stop-cock and the boiler using the food quality hose 
provided. (do not use red or blue washing machine hoses as these will contaminate the 
water) 

ELECTRICAL SUPPLY 

3.

 

The 3kW model is fitted with a 13amp plug and should be plugged into a suitable socket. The 
6kW model should be wired into a 30amp switched supply with an ELCB. (Only a suitable 
electrician should undertake this work) 

COMMISSIONING     

4.

 

Open the steam tap on the left hand side of the unit 

5.

 

Switch on using the switch on the front panel. The power light will illuminate and water will 
start to enter the boiler. Once the bottom level sensor is reached. the unit will then start to 
heat. When the water boils, steam will start to come from the steam nozzle. The steam tap 
can then be closed.  

6.

 

The pressure in the boiler will start to rise and the needle in the gauge will respond. When 
the needle reaches the pre-set pressure, the ready light will illuminate and the boiler will 
start to fill and heat until it reached the high level sensor. The boiler is then ready to use.  

Содержание Barista Pro WB-2

Страница 1: ... Pro Range MODELS WB 2 WB 2 6KW Auto Fill Catering Steam Water Boiler INSTALLATION AND USER INSTRUCTIONS INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB2 ISS 02 ...

Страница 2: ...ARES SERVICE INFORMATION 7 SERVICE WARNINGS FAULT DIAGNOSTICS 8 GUARANTEE 9 INTRODUCTION Dear Customer Thank you for purchasing this Instanta product Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more...

Страница 3: ...sion or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference PLEASE NOTE These units should be insured and inspected annually ...

Страница 4: ...ese will contaminate the water ELECTRICAL SUPPLY 3 The 3kW model is fitted with a 13amp plug and should be plugged into a suitable socket The 6kW model should be wired into a 30amp switched supply with an ELCB Only a suitable electrician should undertake this work COMMISSIONING 4 Open the steam tap on the left hand side of the unit 5 Switch on using the switch on the front panel The power light wi...

Страница 5: ...l surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet SERVICE WARNINGS AND FAULT DIAGNOSIS Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault conditions Some of these are less serious and...

Страница 6: ...k lime scale or broken probe wire 8 Pressure switch wire has shorted wire A 9 Pressure switch wire has shorted wire B 10 The element s have been trying to heat the water but have failed to do so The element s or control system have failed 11 Water supply is turned off and the low probe has become exposed Probable lime scale build up or water supply problem SERVICE TECHNICAL SUPPORT Tel 01704 50291...

Страница 7: ...ble for problems caused by hard water 2 Dripping Taps These components are subject to wear and tear but in the event of a tap failing within twelve months of installation we will be pleased to replace the tap assembly by post Fitting is very simple and requires no tools An engineer call out is not necessary 3 Accidental damage misuse or use not in accordance with these instructions and damage caus...

Отзывы: