b) Summary Alarms-Events
If the problem that caused the fault (faulty sensor, lack of air, temperature problem) is solved, the fault
light goes out automatically.
: Removes unpaid defects that are no longer in progress (repair done).
If this support is not enough, stop and restart the machine (press the emergency stop).
List of alarms / events :
Active fault
Inactive fault
Alarm 00 : PT100 sensor
Loss of signal from the sensor (sensor or cable). The
heating control is instantly deactivated.
Alarm 01 : Overheat
Temperature over 220°C
Temperature is over 230°C. The heating regulation is
instantly deactivated.
Alarm 02: Plate security activated
The detection is immediate. Heating control and
pressing are instantly deactivated.
Alarm 03 : Temperature regulation
trouble (Static relay or other)
Indicates the abnormal difference between the
activation of the analog output and the delta of the
corresponding temperature. (Cable, resistance or static
relay problem).
Alarm 04 : Pressure under value
Indicates the abnormal pressure. Check supply pressure.
To valid air supply, push two green buttons (see
pictogram)
Alarm 05 : Pressing upper sensor not
reached
Signal not detected after 5 seconds. Result of sensor
failure, lack of compressed air supply, mechanical lock,
...).