background image

69

Chapter Nine Server Installation Guide

space between cabinet front and back angle rail (mobile rail) according to the depth of 
the server.

9.2 Install Server Chassis Handles

1. Take chassis handles and fixed screws out of the package, and install handles 

on both sides of chassis.

 

Figure 1

2. Each chassis handle is fixed with six countersunk screws.

 

Figure 2

3. Chassis handle installation is complete.

Содержание NP5540M3

Страница 1: ...umankind s benefit This manual is the property of the Inspur Group Co Ltd This User Manual is not to be copied by any group or person in any manner without the consent of Inspur Group Co Ltd The Inspur Group Co Ltd reserves the right of revising this manual momentarily Any alteration about the content of this manual will not be informed Please contact Inspur Group Co Ltd if you have any questions ...

Страница 2: ...onfusedly 4 When you have any software problems during the application of this server we hope that you firstly contact the corresponding software supplier and then he will contact us in favor of communication so as to solve your problem together especially the software problems about the database the installation and running of the network management software or other networking product 5 The pict...

Страница 3: ...how to set up the RAID of the onboard SAS controller is intro duced Chapter Six Operating System Installation In this chapter how to install the mainstream operating system to this server is in troduced Chapter Seven Common Problem and Troubleshooting In this chapter solutions of some common problems are introduced Chapter Eight Instruction of Integrated Management Card Management Function In this...

Страница 4: ...e SAS RAID Setup 29 5 1 How to Enter the Configuration Interface of SAS RAID 29 5 2 Control Key Application 29 5 3 SAS RAID Setup 29 Chapter Six Install Operating System 33 6 1 Application Instructions for Inspur driver U disk 33 6 2 Manually Install Windows Server 2008 Enterprise Edition 38 6 3 Manually Install Windows Server 2008 Enterprise Edition 44 6 4 Manually Install Red Hat Enterprise Linu...

Страница 5: ...nagement Chip BMC IP 59 8 2 Remote Login 59 8 3 Function Menu Introduction 60 Chapter Nine Server Installation Guide 68 9 1 Cabinet Preparation 68 9 2 Install Server Chassis Handles 69 9 3 Server Slide Rail Suite 70 9 4 Install Inner Rail 71 9 5 Install Outer Rail to Cabinet 72 9 6 Install Server to Cabinet 73 ...

Страница 6: ......

Страница 7: ...les matched with correct earthed plug and check the ratings of the extended cables to make sure that the sum of rated current of all products inserted into the extended cables do not exceed 80 of the limits of the rated currents of the extended cables Warning 4 Please be sure to use the supplied power supply component such as power lines power socket if supplied with the equipment etc For the safe...

Страница 8: ...he chassis besides carefully read the installation de scription attached with the cabinet products and get known about the special warning notices and installation process you must abide by the following preven tive measures to guarantee the cabinet to be stable and safe Warning 10 Before installing equipment in the chassis please install front and side supporting feet on the independent chassis f...

Страница 9: ... that the system is fully dried Close the cover of the host re connect the system to the power socket and then start the equipment In case of operation failure or abnormal situation please contact Inspur and get technical support 3 Pay attention to the position of the system cables and power cables wire them in places not to be stepped on or knocked down and ensure not to place other objectives on...

Страница 10: ...binet regularly to conduct off the static electricity on the body that may damage the internal components 7 When dismounting the internal components with the approval of Inspur please pay attention to the following matters Switch off the system power supply and disconnect the cables including discon necting any connection of the system When disconnecting the cables please grab the connector of cab...

Страница 11: ...hen pulling out the components from the cabinet it shall apply force slightly to ensure the cabinet to keep balance and stabilization When pressing down the release latch of the sliding rail of components and slid ing in or out please be careful as the sliding rail may hurt your figures Never make the AC power branch circuit in the cabinet overload The sum of cabinet load shall not exceed 80 of th...

Страница 12: ... of capacity of single memory board I O Interface USB Interface 2 front USB interfaces 4 rear USB interfaces 1 built in Type A USB interface Serial Interface 1 rear serial interface 1 built in serial interface Network Interface 2 RJ45 network interfaces 1 exclusive management interface Display Interface 1 rear VGA interface ID Indicators and Buttons ID Indicators and Buttons In the back part of th...

Страница 13: ...t 3 with dual CPU sup port 2 with single CPU 2 PCIE 2 0 x4 slots support 2 with dual CPU sup port 1 with single CPU 1 PCI slot Hard Disk Hard Disk Type 3 5 SATA hard disks 2 5 SATA and SAS hard disks different models support different disk types please re fer to the actual configuration Hard Disk Number Support up to 4 pieces of built in 3 5 SATA hard disks Support up to 16 pieces of hot swap 2 5 ...

Страница 14: ...ingle power supply 2 2 5 module 2 pieces of RAID adapters Environment Parameters Operating Environment Temperature 10 35 Non Operating Environ ment Temperature 40 55 Operating Humidity 35 80 relative humidity Non operating Humidity 20 93 40 relative humidity 2 2 Front Panel View The front door of this server can be locked by the chassis lock as shown in the following picture Front door view ...

Страница 15: ...be divided into 2 5 hard disk configuration and 3 5 hard disk configuration ac cording to the configured different hard disk types The following picture is just for reference The actual purchased machine will prevail The front panel view of 2 5 hard disk configuration The front panel view of 3 5 hard disk configuration ...

Страница 16: ... the chassis key in the accessory box to open the chassis safety lock 10 Optical drive Different configurations will lead to the differ ent installation places of optical drive 11 USB interface For connecting USB device 12 USB interface For connecting USB device 13 9 16 hard disks 2 5 hard disk configuration 9 16 pieces of 2 5 hard disk installation position 14 1 8 hard disks 2 5 hard disk configu...

Страница 17: ...on install built in 3 5 SATA hard disk 20 Built in hard disk 4 installation position 3 5 hard disk configuration install built in 3 5 SATA hard disk 2 3 Back Panel View Back panel view Number Name Function and Introduction 1 Power supply switch When the switch is on the server can be started by pressing the Power button on the frontend of the chassis while some optional power supply has no this sw...

Страница 18: ...erface 9 82574 network card 1 inter face Integrated 82574 network card 1st interface Used as onboard IPMI multiplex manage ment interface 10 USB interface For connecting the USB device 11 USB interface For connecting the USB device 12 ID light and ID button After the server connects with the power sup ply press this button and this light is blue to locate the machine The light will be off when you...

Страница 19: ...sponding origi nal setup Hence when there are operating problems in the system due to the alteration the setup can be restored 2 The factory default system setup is usually the optimized setup Don t try to al ter the parameters before you understand their denotations 3 The common setup is introduced in detail in this chapter For items less used in the application this chapter only offers simple in...

Страница 20: ...r exiting BIOS setup etc Introduction of operational keys Button Description up For selecting the upper menu or value down For selecting the next menu or value left For selecting the left menu or value right For selecting the right menu or value Esc For returning to the superior menu or the main menu For changing the item value For changing the current menu item into the previous item value The ke...

Страница 21: ...ed characteristic items Improper setup can result in abnormal system operation Default configurations are strongly recom mended The following are the introductions for main and common used menus or items CPU Configuration Socket 0 1 CPU Configuration This menu is used to display detailed information of currently installed CPU Hyper threading CPU hyper treading function setup includes Disabled and ...

Страница 22: ...an support 4 SATA 3 0Gb s devices Serial ATA Controller 1 This item only appears when SATA Mode option is set to IDE Mode When set to Enhanced it can support 2 SATA 3 0Gb s devices USB Configuration This menu is used to set some configuration related to USB and displays the USB devices automatically detected by the system Legacy USB Support The traditional USB devices support function setup and th...

Страница 23: ...guration supports Mirroring and Sparing the two function modes status displayed above this configuration item should be Supported otherwise the status should be Not Possible To realize Mirroring function the second and third memory slot corresponding to the CPU0 and CPU1 should be full of memories under two CPU configuration 8 pieces of memory should be inserted and the second channel and third ch...

Страница 24: ... Oprom This item is used to open or close integrated SAS controller ROM including En abled and Disabled default configuration two items When SCI devices item is set to Disabled this item is automatically hidden When this item is set to be Disabled it can connect 4 pieces of SATA hard disks as storage Please set this item as Enabled when the server is connected to SAS hard disks or SATA hard disks ...

Страница 25: ...event logs reach the maximum record number It includes the following two items Do nothing default configuration do nothing about the log Erase Immediately erase the log immediately BMC Network Configuration This menu is used to set up the configuration information of BMC network inter face Lan channel 1 Related items of this menu can be used to setup the access method to IP address when 82574 netw...

Страница 26: ...on and the system will display optional boot device table Then select a device through arrow key in the table and press Enter to finish the setting of the boot order item Hard Drive BBS Priorities Press Enter to enter the sub items of this menu and set up the boot order of the hard drives 6 Security menu Administrator Password This menu is used to set up system administrator password After the set...

Страница 27: ...he BIOS settings will be saved and the system will not exit the BIOS setup Discard Changes Select this item and press Enter After you select Yes for confirmation the changes in the BIOS settings will be discarded and the system will not exit the BIOS setup Restore Defaults Select this item and press Enter After you select Yes for confirmation the system will load system default optimization setup ...

Страница 28: ...motherboard jumper change is needed please get the authorization of Inspur Group Co Ltd according to the methods as follows to open the chassis front panel and side panel 1 Open the front panel using the chassis key in the accessory box 2 Open the front door and loosen the four screws as shown in the circle in the following picture Loosen the four fixing screws on the chassis front panel ...

Страница 29: ...ed by an arrow then take it off Take off the chassis front panel 4 Loosen the 2 screws fixing side panel in the following figure and open the right side panel see from the rear of the chassis Take off the side panel 3 2 2 Introduction of Common Motherboard Jumper Function In following is the layout of common motherboard jumper ...

Страница 30: ...ting pin1 and 2 normal state default Short cutting pin2 and 3 clear CMOS Notes 1 When clearing CMOS the system must be shut down and cut off the power supply Short cut pin2 3 for 5 seconds And then reuse jumper cap to short cut Pin1 and Pin2 default state and restore to the original state 2 After the jumper operation please install the upper panel of the chassis ...

Страница 31: ...me press Ctrl I to enter SATA Host RAID configuration interface 4 2 Control Key Application Key Description For moving cursor and modifying menu option value in different menus TAB For selecting the next menu configuration items Enter For selecting menu Esc For exiting menu or back to the previous menu from submenu 4 3 SATA HostRAID Setup After entering the SATA HostRAID configuration interface th...

Страница 32: ...nd down arrow keys and then press Enter key to create RAID volume menu The system will display the following menu options Name Please input the volume name of less than 16 characters without special characters RAID Level Please select RAID volume level If it has not created volume at present there are four volumes for selection such as RAID0 Stripe RAID1 Mirror RAID10 RAID0 1 and RAID5 Parity and ...

Страница 33: ...TED DISKS WILL BE LOST Are you sure you want to create this volume Y N If the creation of RAID volume is confirmed please enter Y The volume will then be created and at the same time all the data on the selected hard disk will be lost If not to create RAID volume please enter N and exit the creation of volume Here we enter Y and create RAID volume After the creation return to the main configuratio...

Страница 34: ... system will again warn whether there is a need to reset the hard disk and enter Y or N according to the prompts Note when resetting the hard disks all data on hard disk will be lost and at the same time the hard disk will not again belong to RAID volume IV Exit menu After entering the configuration interface of SATA HostRAID you can select the menu by the up and down arrows and then press Enter k...

Страница 35: ...splay Press CTRL I to enter Configuration Utility 2 At this time press Ctrl I to enter SAS RAID configuration interface 5 2 Control Key Application Key Description For moving cursor and modifying menu option value in different menus TAB For selecting the next menu configuration items Enter For selecting menu Esc For exiting menu or back to the previous menu from submenu 5 3 SAS RAID Setup After en...

Страница 36: ... can select the menu with up and down arrow keys and then press Enter key to create RAID volume menu or you can input the number key in front of the menu directly to create RAID volume menu The system will display the following menu options Name Please input the volume name of less than 16 characters without special characters RAID Level Please select RAID volume level If it has not created volume...

Страница 37: ...ch is defaulted as the maximum capacity Alter all the settings above have been done well please select Create Volume and press Enter The screen will display WARNING ALL DATA ON THE SELECTED DISKS WILL BE LOST Are you sure you want to create this volume Y N If the creation of RAID volume is confirmed please enter Y The volume will then be created and at the same time all the data on the selected ha...

Страница 38: ...o be reset by Space key based on actual demand and then reset hard disk by pressing Enter key The system will again warn whether there is a need to reset the hard disk and enter Y or N according to the prompts Note when resetting the hard disks all data on hard disk will be lost and at the same time the hard disk will not again belong to RAID volume IV Exit menu After entering the configuration in...

Страница 39: ...iver U disk you may refer to relevant contents of this chapter for the making method of Inspur driver U disk If your server is configured with external RAID card or SAS sub card please refer to the electronic version of User Manual in the CD of external RAID card or SAS sub card to load the driver of the hard disk controller If it uses onboard SATA controller please make the driver of controller a...

Страница 40: ...ot it must enter the server BIOS for setting to ensure the starting sequence of hard disk is prior to the starting sequence of U disk and the system can boot from the disk If the starting sequence of U disk is prior to the starting sequence of hard disk the system will fail to boot from hard disk The following introduces the making method for the driver of onboard hard disk controller when using I...

Страница 41: ...ver under Windows system shall be identified to be A and only by this can the subsequent normal driver making be guaranteed 2 Put the driver CD Inspur system driver CD and RAID card driver CD into optical drive and the driver making software will operate automatically If the system forbids the automatic operation of CD please enter CD directory and operate dolphin bat Inspur system driver CD in CD...

Страница 42: ...et or name plate then log in the drive making software main interface Click Exit to exit the log in In the drop down menu below Please select the machine type select the specific product model the specific model please refer to host nameplate label 2 After inputting the navigation No and logging in enter the main interface of driver making software and the main interface is shown in the following ...

Страница 43: ... floppy drive A of Inspur driver U disk and then click OK to start the driver making After the driver making is completed the system will pop up the window prompt ing Driver has been completed Click OK to complete the making of driver Notices for using Inspur driver U disk to load driver under windows system During the installation of Windows operating system if the driver of hard disk controller ...

Страница 44: ...drive Please select to make or install the driver corresponding to the version of system according to the operating system version selected to install Note When making the above driver if you use USB floppy please make the driver in the floppy disk if you use Inspur driver U disk please make the driver in the Inspur driver U disk 6 2 2 Installation Steps 1 Connect USB floppy drive or Inspur driver...

Страница 45: ...m the drive list and press Enter to load driver If Inspur driver U disk is used please connect Inspur driver U disk well be fore the system starts up Firstly ensure that the corresponding driver has been made into the 3 5 Floppy disk A partition of the Inspur driver U disk If onboard SATA controller AHCI configuration is used select Intel R C600 Series Chipset SATA AHCI Controller from the driver ...

Страница 46: ...isk parti tions you want to create and then press Enter to continue Notes it is suggested that the partition should be more than 30GB 8 The system displays the interface of Step 6 here select the partition of Partition1 New Raw and press Enter key to continue the installation 9 The system displays Format the partition using the NTFS file system Quick Format the partition using the NTFS file system...

Страница 47: ...uations and then click Next to continue the installation 14 Input your Product Key 25 character and then click Next to continue the installation 15 Licensing Modes Windows Server 2003 supports two licensing modes Per server Number of concurrent connections Each connection must have its own Client Access License Per Device or Per User Each device or user must have its own Client Access License The ...

Страница 48: ...input the navigation code on the driver CD case or select ma chine type for the specific type please check the host nameplate tag and click OK to enter the installation interface automatically 2 In Select OS column select Windows 2003 3 In Select Hardware column select Chipset patch 4 Click Next to start the installation 5 Enter the interface of Welcome to the Setup Program and click Next to conti...

Страница 49: ... not exit the installation interface of driver CD but continue the installation of video driver installation 1 In the Select OS column select Windows 2003 2 In the Select Hardware column select Video driver 3 Click Next to start the installation 4 Enter the interface of Welcome to the InstallShield Wizard and click Next to continue 5 Enter the interface of Ready to Install the Program and then cli...

Страница 50: ...t in the interface of Computer Management open Device Manager 2 In the interface of Device Manager select PCI device in the Other de vices right click and select Update Driver 3 The system pops up the window of Welcome to the Hardware Update Wiz ard If the system inquires Can Windows connect to Windows Update to search for software select No not this time and click Next 4 The system displays the w...

Страница 51: ...ot from CD 2 Press any key when the system presents Press any key to boot from CD or DVD and the system will start Windows installation program from CD 3 According to actual needs set Language to install Time and currency format Keyboard or input method And then click Next to continue 4 In the interface of installation confirmation click Install now to continue 5 The system pops up Load Driver win...

Страница 52: ...e It can format the partitions by selecting the existing partitions and clicking Format It can create new partitions by selecting unallocated disk spaces and then click ing New to create new partitions You can operate according to the actual demands Here we d expound on the issue when there are no existing partitions in the disk 1 Select the unallocated space click New delete the number in the Siz...

Страница 53: ...edure item in the automatically playing interface popped out after the disk s running Enter Welcome to use Inspur driver CD window input the navigation code on the driver CD case or select machine type for the specif ic type please check the host nameplate tag and click OK to enter the installation interface automatically 2 In Select OS column select Windows 2008 3 In Select Hardware column select...

Страница 54: ...o Install the Program and click Install to continue 10 The installation program starts to install when the installation is completed click Finish according to the prompt 18 Install Video driver After installing the network card drive please do not exit the installation interface of driver CD but continue the installation of video driver installation 1 In the Select OS column select Windows 2008 2 ...

Страница 55: ...rface of Update Driver Software When the system asks How do you want to search for driver software please select Browse my computer for driver software 4 The system prompts Browse for driver software on your computer After putting the Inspur driver CD into the optical drive click the Browse button in the back of Search for driver software in this location and select the path of the driver in the C...

Страница 56: ...llation 5 The installation program goes to What language would you like to use during the installation process interface Select to install language version of the operating system Here we select English English for installation and click Next to con tinue 6 The installation program enters Select the appropriate keyboard for the sys tem interface Please select keyboard type according to actual situ...

Страница 57: ...ation would you like This is the installation selection interface including Use All Space Replace Existing Linux System s Shrink Current System Use Free Space Create Custom Layout This installation takes custom manual partition as an example so select Create Custom layout and click Next to continue the installation 12 The installation program enters the interface of Select the hard disk to in stal...

Страница 58: ...ion program enters Boot Loader setting interface set as needed and click Next to continue the installation 16 The system prompts The default installation of Red Hat Enterprise Linux is a basic server install You can optionally select different sets of software now Please select the type to install and the software package that needs customization according to actual demand so select Customize now ...

Страница 59: ...d Password to log in the system 27 Install network card driver After the operating system installation it will automatically load onboard network card driver You can use the driver CD attached with the machine to update the network card manually 1 Insert Inspur driver CD into the optical drive click the Terminal menu in Applications System Tools input the following in the windows cd mount dev cdro...

Страница 60: ...e Restart the software clear up system memory and restart the op erating system Ctrl Alt Del Clear up system memory self check the POST again and restart the operating system Reset button Cold boot again switch off and restart the system power so that to clear up the system memory to self check the POST again to restart the operating system and to power up all peripherals again Power button 7 2 Pr...

Страница 61: ...r test if possible 6 If the machine is installed with components other than Inspur ones please re move them first 7 With the permission of Inspur technical support personnel you may pull and plug RAM and clear CMOS for test 7 2 3 Installation System Can t Find Hard Disk 1 When installing the system directly booted with the system CD if it prompts that no hard disk can be found please check the nor...

Страница 62: ...lication program software are installed before the fault it is suggested removing it and going on to test your serv er 2 Use the latest antivirus software for antivirus test 3 It is suggested that you record the displayed information code for blue screen such as stop c000000218 stop 0x0000007b This kind of information reveals prob lems in the system It is suggested that you reinstall it For the in...

Страница 63: ...n faults there is high possibility of something wrong with motherboard You can try to pull or plug RAM or clear CMOS if the starting self check is normal and the alarm starts when the RAID card is under test and there is abnormal array information then it is likely that the RAID card has set off the alarm There may be array abnormal ity when the hard disk back plane alarms there is always abnormal...

Страница 64: ...ort4 Port5 item to Disabled At this time the system will be installed to the first physical disk After the completion of operating system installation set SATA Port3 Port4 Port5 item to Enabled In the HostRAID mode please record the name of the RAID volume when you are doing the RAID setting When installing the operating system please distinguish the name of RAID volume so that the operating syste...

Страница 65: ...he actual use of the network card If you reset IP address of IPMI card only after saving and restarting the server or powering off disconnecting the power can you make it into normal use 8 2 Remote Login 1 Remote Client System Requirements The requirements of remote client system of GUI interface connecting to the serv er management chip through web browser are shown in the following table Require...

Страница 66: ...ktop 2 Remote Login Method Input IP address of BMC in the IP address bar of client browser and then click Enter The management log in interface will appear just as shown in the following picture Please input default Username and Password Username admin Password admin Notice default Username and Password can conduct all module configurations and setting of permission So for security reasons it is r...

Страница 67: ...hen using if prompt ed to install Jviewer browser please install according to the prompt 2 FRU Information menu This menu displays FRU Information including Basic Information and Server Information two parts Basic Information shows ID number and names of FRU device Server Information displays server whole machine s type name manufacturer and other information Following are the detailed information...

Страница 68: ...solute mode mouse can switch freely between remote picture and local picture Set Mode to Relative Recommended when server OS is Linux the relative mode mouse can switch between remote picture and local picture by selecting Alt M Network menu set network Please change IP address or select DHCP accord ing to needs NTP menu set date and time to be synchronous with time server or set at will If the re...

Страница 69: ...s Console Redirection menu log in console After choosing this menu and click Java Console button the system will log in remote desktop When using if prompted to install Jviewer browser please install ac cording to the prompt A Remote desktop Video menu Menu Function Pause Redirection Pause remote desktop display Resume Redirection Resume remote desktop display Refresh Video Refresh remote desktop ...

Страница 70: ...Press and Release It stands for press down or release Win dows key on the left side of the keyboard Right Windows Key Selecting this option will appear Hold down and Press and Release It stands for press down or release Win dows key on the right side of the keyboard Ctrl Alt Del Select this option equal to press Alt Ctrl Del Context Menu Shortcut menu Notes when configuring RAID through remote con...

Страница 71: ...or minify the window of remote desktop Zoom In for magnifying and Zoom out for minifying E Remote desktop Media menu Click Media menu It will appear Virtual Media Wizard window In this win dow the user can load client side floppy disk image CD image and CD drive as is shown in figure below Select image type to load If to load floppy disk image please select Floppy Im age And if to load CD image pl...

Страница 72: ... video record Menu Function Start Record Select this option and start video record Stop Record Select this option and stop video record Settings This option is used to set video record duration and storage direc tory Only after the directory is set can the video record begin H Remote desktop Help menu Click Help menu A drop down menu About JViewer appears Select this op tion and redirection browse...

Страница 73: ...cute After that ID light of front and back panel of corresponding server will be off 6 Maintenance menu This function menu can realize remote update of BMC firmware and restart of IPMI card Firmware Update menu This menu can realize remote update of IPMI management card Firmware We recommend users not updating it by themselves If it really needs to be updated the up date file must have been approv...

Страница 74: ...ric shock a grounding device must be installed in the cabinet If the server power line is installed in the power socket which consti tutes a portion of the cabinet grounding should be properly provided for the cabinet If the server power line is inserted into the power socket in the wall the grounding device in the power socket just provides grounding for the server and then proper grounding prote...

Страница 75: ...rail according to the depth of the server 9 2 Install Server Chassis Handles 1 Take chassis handles and fixed screws out of the package and install handles on both sides of chassis Figure 1 2 Each chassis handle is fixed with six countersunk screws Figure 2 3 Chassis handle installation is complete ...

Страница 76: ...l suite attached with server NP5540M3 contains the following items 1 Outer rail 2 2 Middddle rail 2 3 Inner rail 2 4 Long adjustment sheet 4 sheets 5 Short adjustment sheet 4 sheets 6 Metric screw 1 package 7 British screw 1 package Long adjustment sheet and short adjustment sheet are shown in the following Figure 4 Figure 4 ...

Страница 77: ...d many other screws The following Figure 5 shows the commonly used round head M5 8 screw round head M4 6 screw and flat washer Figure 5 Inner rail middle rail and outer rail have been installed together as is shown in Figure 6 Figure 6 9 4 Install Inner Rail 1 Firstly take inner rail out of slide rail hold the front end of the whole slide rail with left hand then pull inner rail outward when it ca...

Страница 78: ... on chassis And also make inner rail stay close to the chassis And then completely fix the inner rail into chassis through 4 round head M4 6 screws based on the location shown in Figure 9 Figure 9 Repeat the above steps to install the other inner rail into the corresponding place on other side of the chassis 9 5 Install Outer Rail to Cabinet 1 Install the long adjustment sheet to the both sides of...

Страница 79: ...ted in the inner side of the cabinet angle hole position one for front the other for the rear and fix the front and rear ends of the outer rail to the cabinet angle rail hole position using 4 round head M5 8 screws two screws for both front and rear ends Please make sure the front and rear part of the outer rail horizontal as shown in figure 11 Figure 11 4 Repeat the above operations install the l...

Страница 80: ... rails 3 Keep the server horizontal and push it stably into the cabinet During the push if the serve is stuck please push the bayonet lock between the inner rail and middle rail in both sides of the server upward or downward the directions are opposite on either side meanwhile push the server into the cabinet as shown in figure 12 Figure 12 ...

Отзывы: