![Inspur NF5266M6 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/inspur/nf5266m6/nf5266m6_user-manual_2069396067.webp)
58
Unable to load the RAID driver or create partitions larger than 2 T during OS
installation; C disk usage is too high after OS installation, etc.
Solutions:
1.
If it fails to load the driver during OS installation, check the RAID driver version.
Go to Inspur website
driver. Some RAID drivers need to be loaded several times.
2.
If it fails to create partitions larger than 2 T during OS installation, select
Advanced
>
CSM Configuration
>
Boot option filter
>
UEFI only
(For detailed
reference document, see
Firmware Update and Configuration
) in BIOS, save
and exit BIOS interface. Choose UEFI to boot the OS. The server will restart
automatically. It needs to enter the CMD command line to change the drive
format to GPT, and then partitions larger than 2 T can be created;
3.
If the C disk usage is too high after installing the Windows OS, turn down the
virtual memory or allocate the virtual memory to other partitions;
4.
If the instructions above do not resolve the problem, please call Inspur
Customer Service Hotline (1-844-860-0011/1-760-769-1847) or email to
.
7.2.2
PXE Boot Failure
Symptoms:
Unable to install OS via PXE.
Solutions:
1.
Check if the PXE server can be used to install OS for another server;
2.
Check whether there is network link via the network port LED to check if there is
a fault in external network;
3.
Check whether the NIC can be identified under BMC Web, BIOS or Shell;
4.
Check if PXE Function is enabled and if the boot sequence is set to first in BIOS;
5.
Check if the target drive for the OS or RAID array can be identified and if there is
enough space;
6.
If the instructions above do not resolve the problem, please call Inspur
Customer Service Hotline (1-844-860-0011/1-760-769-1847) or email to
.
7.2.3
Abnormal Memory Capacity
Symptoms:
The memory capacity displayed in the OS and the physical memory capacity are