9
Inspur proprietary and confidential information
Copyright © Inspur Electronic Information Industry Co., Ltd.
SAS 3008
)
Prerequisites
The structure of the mainboard and hard disk backplane is
proper, and hard disks are detected after the server is powered
on.
Procedure
1.
Power on the system, log in to the web interface through
the management network port. Press Ctrl+C to enter
controller card setup screen during the system
startup.( UEFI mode needs to be viewed in the BIOS)
2.
View the LSI SAS 3008 BIOS version and the firmware
version on the displayed screen.
3.
On the Adapter Properties screen, check the NVDATA
version.
4.
。
On the SAS Topology menu, expand the menu, and
check the hard disk model and quantity.
Expected result
1.
The SETUP screen is displayed after you press Ctrl+C.
2.
The LSI SAS3008 BIOS versions, firmware versions, and
NVDATA versions are displayed.
3.
The hard disk model and quantity are the same as actual
configurations.
Description
None
Table 1- 8 Hard Disk Controllers
Item
Content
Objective
To verify that the RAID controller card operates properly.
(
LSI
SAS 3108
)
Prerequisites
The structure of the mainboard and hard disk backplane is
proper, and hard disks are detected after the server is powered
on.