background image

The thermostat is preset at the factory at approximately 190

° 

F.

If you wish to adjust the water temperature, turn the thermostat
adjustment screw clockwise to increase the temperature and
counterclockwise to decrease it (see illustration above). The
cover must always be in place for the thermostat to respond
properly. Wait for water to heat up or to cool down. Then, draw
some water. If temperature still is not to your liking, repeat the
procedure. 

Do not allow water to boil.

Beginning from the date of installation through one year of use
in your home, we will repair or replace at no charge defects in
material or workmanship which appear in the dispenser. If your
dispenser is replaced rather than repaired, the warranty on the
new unit shall be for the duration of the remaining portion of the
original dispenser’s warranty. Please call the nearest Factory
Authorized Service Center when service is needed.

For the location of your nearest factory authorized service 
center, call this toll free number: 1-800-558-5700 USA 
(1-800-367-9811 Canada).

This full one-year warranty applies only if the unit is installed 
in accordance with these installation instructions, is used on 
circuits and currents specified, and has had normal use and
service.

The foregoing warranty does not apply to damage or inoperation
resulting from accident, alteration, misuse, abuse, improper
installation, installation not in accordance with these instructions
or local electrical and/or plumbing codes or shows evidence 
of having been started up “dry”.  We do not assume any
responsibility for consequential damage.

Full One-Year Warranty

Service/Maintenance Instructions

What if water is dripping from the spout?

If water drips from the spout, draw 2 or 
3 cupfuls while unit is heating. This will
drain any water out of the unit’s expan-
sion chamber. If water still drips prior 
to the automatic thermostat shutting 
off (you can hear it), turn thermostat 
to a slightly lower temperature setting.

If the water pressure occasionally drops below 20
pounds per square inch (138kPa), the expansion
chamber of the tank may not be draining properly.

In such a case, water may drip out of the spout until the incom-
ing water is hot enough to turn off the thermostat. As soon as
adequate water pressure is restored, the next drawing of water
will clear the expansion chamber. Occasional drops in water
pressure will not harm the operation of your unit.

What to do if something goes wrong

1.  If the dispenser’s flow of water slows or stops, make sure

the shutoff valve is not plugged or turned off. To unplug the
valve, turn it all the way off and then open it all the way. This
may dislodge any foreign material. If this does not work, then
unplug the power cord and contact your service center.

2.  Be sure dispenser is plugged firmly into a properly grounded

outlet.
Check that fuses and circuit breakers are working. Reread
instruction booklet to assure that you are using correct 
operating procedure. Many unnecessary service calls 
result in the service agent doing what the owner can do 
for himself or herself.

3.  Contact your local authorized service center. For the loca-

tion of your nearest factory authorized service center call
1-800-558-5700 USA (1-800-367-9811 Canada).

4.  Write to us if a satisfactory solution is not reached in the

steps above. Our address is shown below.

Electric shock hazard

•  To prevent electrical shock, disconnect power before remov-

ing access cover to service the thermostat.

Scalding hazard

•  Do not allow water to boil. May result in severe burns.

Fire/product damage

•  Do not remove or alter the thermal safety fuse.
•  If you suspect the thermal fuse is open contact your ISE

Authorized Service Center.

Adjusting Temperature

Note: Use only mild cleaners to clean the dispenser spout
and plastic components. Use of cleaning agents containing
acids, alkalines and organic solvents will result in deteriora-
tion of plastic components.

Manufactured by IN-SINK-ERATOR

The Emerson logo is a trademark and servicemark of Emerson Electric Co.
In Sink Erator is a division of Emerson Electric Co.

4700 21st STREET, RACINE, WI 53406-5093
ASSEMBLED IN MEXICO

Содержание Hot1

Страница 1: ...is unsupervised access to this appliance Capacity 1 3 gallon 1 3L up to 40 cups of 190 F 88 C water per hour Electrical 115 volts A C 4 3 amps 500 watts Energy consumption 95 KWH day Three wire cord...

Страница 2: ...o minimize possibility of fire do not store flammable items such as rags paper or aerosol cans near the tank Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this...

Страница 3: ...ray hose from the bottom of the faucet CNow pull the spray head and hose entirely out of the hole Then plug the faucet tube opening with either a 1 8 inch plug or 1 4 inch cap not supplied DNext remov...

Страница 4: ...1 3 8 35mm chassis punch such as the one shown at right Rent or purchase one at your hardware or electrical supply store Or mount the Hot Water Dispenser s head in a 1 3 8 35 mm hole drilled through...

Страница 5: ...pproximately two turns BWhile holding the dispenser in place with spout removed slip the rubber gasket and mounting nut over the valve lever and hand tighten the nut on the threaded barrel CAlign the...

Страница 6: ...tric Shock Hazard Never use an electric drill to drill into water pipes It can result in an electric shock Use a non electric hand drill The recommended connection can be made using a shutoff valve Th...

Страница 7: ...water Failure to do so may damage heat ing element or thermal safety fuse and will void your warranty Flow restriction Make sure the bends in tubing are smooth and not kinked Don t use paste type sea...

Страница 8: ...ing If the water pressure occasionally drops below 20 pounds per square inch 138kPa the expansion chamber of the tank may not be draining properly In such a case water may drip out of the spout until...

Отзывы: