RL-30 Undercounter December 2016 9 www.insingermachine.com 800-344-4802
PART 3 OPERATING INSTRUCTIONS
NOTE:
The booster heat
and wash heat
thermostat are
located behind the
front kick panel.
Booster B1
Wash B2
Turn clockwise to
increase set
temperature.
TempGuard
™
B7
WARNING:
Do not open the
door while the
program is running.
There is a risk of hot
water spraying out
of the machine.
(The unit is
equipped with a
door safety switch,
located behind the
door.)
OPERATING INSTRUCTIONS
Turn on the main power, S1. The machine will
fill. the booster tank fills and continues until the
wash tank of the machine is full.
*
Once the wash
tank is full the booster tank heater (R1) is turned
“on”. Once the booster has reached operating
tempera- ture 185°F (85°C) (set by B1) the wash
tank heater (R2) is activated until optimal wash
temperature 158°F (70°C) (set by B2) is reached.
At any point during the heating cycle of the
booster and/or the wash tank, a cycle may be
started by pressing the cycle switch (S4). If final
rinse temperature has been achieved the unit will
run a normal 2 minute cycle and stop. If final rinse
temperature has not been achieved the unit will
stay in wash mode until the final rinse reaches
preset temperature (TempGuard
™
feature).
TempGuard
™
is adjustable
by B7,
TempGuard
™
thermostat.
*
The water level in the wash
tank should be within a 1/2
”from
the top of the overflow drain
pipe.
CAUTION:
Do not place anything on the
open door.
Initial Start-Up
Power switch on (Green button)
S1
Power light illuminates
H1
Rinse solenoid opens
Y1 (Only if door is closed)
Rinse booster fills
Wash tank fills until pressure switch is closed
B3
Rinse tank heater turned
“ON”
R1
Rinse temperature reached
B1
TempGuard
™
light turns
“ON”
H5
Wash tank heater is turned
“ON”
R2
Wash temperature reached
B2
Continuing Operation
Depress
“Cycle Start” switch
S3
Cycle light illuminates
H2
Cam timer starts
D1
Rinse shot (~2 sec)
D1 cam 3 (
initiates solenoid
Y1)
Wash cycle (~101 sec)
D1 cam 2 (
initiates solenoid
KM3)
Dwell (~3 sec)
Rinse Cycle (~11 sec)
D1 cam 3 (
initiates solenoid
Y1)
Drain cycle (0-1 min)
D1 cam 3 (
initiates solenoid
KA5)
Dwell (~3 sec)
Cam timer stops