background image

 

www.insigniarange.com

 

Last Modified: 31/08/2018

 

 19 

Silicone the area highlighted in red 

where the glass panel frame meets at 

the bottom (next to the column)

 

Silicone fill the area highlighted in red at 

the end of the bottom runner as         

indicated in the image on the left.

 

Silicone Seal (vertical joints)

 

-

 

RubberGum (horizontal joints)

 

TESTING FOR WATER LEAKS

 

LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALANT TO CURE AND ENSURE THE SHOWER IS 

AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING

 

Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model dependent) on your 

shower. 

We also advise to run a thin bead of silicone around the control panel.

 

Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and are not suitable for 

checking leaks as they would normally only operate when a person is in front of them. DO NOT AIM THE HAND SHOWER 

AT THE JOINTS OF YOUR SHOWER AS THIS DOES NOT FALL UNDER 

NORMAL EVERYDAY USE

”. 

Adjust the feet 

to ensure the  direction of the water flows towards to the waste to prevent puddling.

 

Just use COLD water setting as hot will make cabin misty and condensate thus the inspection becomes very difficult. Now 

on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip and jet by walking from one side and going 
around to the back and then to the other side finishing at the front. If you have a small leak (normally caused through 

insufficient sealer or air bubble on assembly, dry the area thoroughly and reseal.

 

Please remember the location of the water may not be exactly where the leak is as it could have run around to a low point. 

Never seal your inner fittings unless necessary, remember you will see this for the life of the shower! Again leave to cure 

and check. Once you are happy check the shower functions i.e. jets for back massage, foot massage and finally hand 

shower (model dependent) check your joints to these functions at the rear again. Never use the shower until 

all

 checks 

have been made and the installer is 100% happy in the knowledge no leaks are present. 

 

Important Note:

 

 

 

It is not uncommon due to temperature changes, 

 

glass seals fitted into the frame lower horizontal and 

sides can and do shrink leaving a small gap. This is normal to prevent rubbers perishing or opening later in your showers 

life. Check yours now, any slight gaps simply seal neatly with a thin bead of silicone. This will prevent chances of leakage 

both now or later in life. 

 

All good?

 

Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final resting position.

 

Happy Showering! 

Содержание INS1999

Страница 1: ...ts Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO _...

Страница 2: ...ion Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Sealing and Water Testing Control Panel Instruct...

Страница 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Страница 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Страница 5: ...e for electrician This product comes with 3 amp plug We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current laws and IP di...

Страница 6: ...Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied Not Supplied Hardware Requirements A Shower Cabin requires 2 x 1 M...

Страница 7: ...assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the uni...

Страница 8: ...placement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Desc...

Страница 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Страница 10: ...www insigniarange com Last Modified 31 08 2018 10...

Страница 11: ...em is for the steam generator drainage and will be con nected in the instructions later Now please level the tray by firstly placing the tray in its final location and then using a spirit level adjust...

Страница 12: ...y the arrows Step 3 The next step is to attach both front uprights and the top rail In order to do this insert the front uprights over the glass seal as push on tightly as directed by the arrows in th...

Страница 13: ...und to the position shown in the image marked 2 Now repeat for the other side 1 2 1 Step 5 Now you have locked the two back panels in position Rubbergum the bottom of the column and align the back pan...

Страница 14: ...justable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all...

Страница 15: ...n the below image Next slide the shelf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing...

Страница 16: ...oughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the imag...

Страница 17: ...your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the wate...

Страница 18: ...Never leave children unattended in the shower or bath Never bath children under 12 using whirlpool function if fitted Regulate the temperature of water before showering Never use this shower if you h...

Страница 19: ...y difficult Now on the OUTSIDE of the shower inspect each joint factory seal hose clip and jet by walking from one side and going around to the back and then to the other side finishing at the front I...

Страница 20: ...nstructions Button 1 VOL Volume Up Button 2 Down Arrow Radio Search Down Button 3 Up Arrow Radio Search Up Button 4 VOL Volume Down Button 5 Power On Off Button 6 Telephone Answer telephone Button 7 F...

Страница 21: ...ww insigniarange com Last Modified 31 08 2018 21 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Страница 22: ...tely 4 meters of U Style seals SP039 Fan model dependent SP171 24 x 10mm White LED Lights Part Code Part Description SP300 Waste hose SP251 Transformer SP308 Magnetic door seals SP310 Rear door seals...

Страница 23: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Отзывы: