Inscape Data Link Power LPS2802-T1 Series Скачать руководство пользователя страница 3

Page | 3 
 

Safety Summary 

The following general safety precautions must be observed during all phases of operation of this 
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this 
manual violates safety standards of design, manufacture, and intended use of the instrument. 
Inscape Data Corporation assumes no liability for the customer’s failure to 
comply with these requirements.  
 

Before Applying Power 

Verify that the product is set to match the available line voltage and all safety precautions are 
taken. 
 

Over Temperature Warning 

To prevent the switch from overheating, do not operate it in an area that exceeds the maximum 
recommended ambient temperature of (75°C). To prevent product cooling restriction, allow at 
least 3 inches (7.6 cm) of clearance around the product after installation. 
 

Ground the Instrument 

To minimize shock hazard, the instrument chassis and cabinet must be connected to an 
electrical ground. The instrument must be connected to the ac power supply mains through a 
three-conductor power cable, with the third wire firmly connected to an electrical ground (safety 
ground) at the power outlet. For instruments designed to be hard-wired to the ac power lines 
(supply mains), connect the protective earth terminal to a protective conductor before any other 
connection is made. Any interruption of the protective (grounding) conductor or disconnection of 
the protective earth terminal will cause a potential shock hazard that could result in personal 
injury.  
 
When installing the unit, always make the ground connection first and disconnect it last. 

 

Jewelry Removal Warning 

Before working on equipment that is connected to power lines, remove jewelry (including rings, 
necklaces, and watches). Metal objects will heat up when connected to power and ground and 
can cause serious burns or weld the metal object to the terminals. 

 

Do not Operate in Explosive Atmosphere 

Do not operate the product in the presence of flammable gases or fumes. 
 

 

Содержание Link Power LPS2802-T1 Series

Страница 1: ...pyright 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the i...

Страница 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Страница 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Страница 4: ...ational electrical codes Do Not Exceed Input and Output Ratings Do not operate the product to exceed the power input and output ratings This product Conforms to the following safety standards Specific...

Страница 5: ...ption Table 8 Grounding Protection 9 Grounding the Switch by Using the AC Power Cord 9 Power Redundancy UPS Input 10 Connector Layout Diagram 10 Waterproof Ethernet Fiber Optics Power Connector Assemb...

Страница 6: ...30 70 C working at a full load 144W for IEEE802 3af with the internal power supply 9 The four gigabit SFP fiber ports are capable of high bandwidth and for up to 120KM long distance transmission 10 Du...

Страница 7: ...he next page Please note the following IP weatherproof rating when close the top cover 1 Closing the top cover by latch the weatherproof IP rating is IP66 2 Closing the top cover by 4 screws included...

Страница 8: ...y Yellow LED ON Connected with 1000Mbps network device OFF No connected PD PoE Indicator PoE Green LED ON Connected PD Device working properly Green LED Blink Short circuit or current overload OFF No...

Страница 9: ...ower cord Please make sure that 1 The power cord extension has a PE Protective Earth terminal Figure 6 Aka Equipment Grounding Conductor 2 The ground contact in the power outlet is securely connected...

Страница 10: ...C to DC UPS or solar powered DC backup UPS Once the DC power is connected the DC power functions as backup power If the AC is not used and the DC power is connected then the DC power functions as the...

Страница 11: ...Plug MUST be used to cover the Sealing Insert if any of the hole is not used in order to maintain waterproof of the connector Installation Mounting You can mount the system with one of the two ways 1...

Страница 12: ...can be order if required 1 Mast Pole Mounting Kit Part No MMK0001 2 SFP Duplex 1 25Gbps 3 3V Single Mode Transceiver Part No SFP SM LC20 DDM 3 SFP Duplex 1 25Gbps 3 3V Multimode Transceiver Part No SF...

Страница 13: ...Page 13 Product Specifications ELECTRICAL PIN OUT DIAGRAM...

Страница 14: ...om U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Customer Service and Orders S...

Отзывы: