Certification 

Inscape Data Corporation certifies that this product met its published specifications at time of 
shipment from the factory.  
 

FCC Statement 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will be required to correct the interference 
at his own expense. 

The user is cautioned that changes and modifications made to the equipment without approval 
of the manufacturer could void the user's authority to operate this equipment. 

The manufacturer is not responsible for any radio or TV interference caused by unauthorized 
modifications to this equipment. Such modifications could void the user’s authority to operate 
the equipment. 

 

Industry Canada Statement 

This Class A digital apparatus complies with Canadian ICES-003. 
 

CE Statement 

This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 
89/336/EEC as amended by European Directive 93/68/EEC. 

Warning: This is a class A product. In a domestic environment this product may cause radio 
interference in which case the user may be required to take adequate measures. 

 
UL Recognized Statement 

The power supply of this product has been investigated using applicable construction and 
performance requirements by UL

, and when installed in accordance with the manufacturer’s 

installation instructions, should provide a safe, code-compliant installation.

 

 

 

Содержание Link Power LPS2802-T1 Series

Страница 1: ...pyright 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the i...

Страница 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Страница 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Страница 4: ...ational electrical codes Do Not Exceed Input and Output Ratings Do not operate the product to exceed the power input and output ratings This product Conforms to the following safety standards Specific...

Страница 5: ...ption Table 8 Grounding Protection 9 Grounding the Switch by Using the AC Power Cord 9 Power Redundancy UPS Input 10 Connector Layout Diagram 10 Waterproof Ethernet Fiber Optics Power Connector Assemb...

Страница 6: ...30 70 C working at a full load 144W for IEEE802 3af with the internal power supply 9 The four gigabit SFP fiber ports are capable of high bandwidth and for up to 120KM long distance transmission 10 Du...

Страница 7: ...he next page Please note the following IP weatherproof rating when close the top cover 1 Closing the top cover by latch the weatherproof IP rating is IP66 2 Closing the top cover by 4 screws included...

Страница 8: ...y Yellow LED ON Connected with 1000Mbps network device OFF No connected PD PoE Indicator PoE Green LED ON Connected PD Device working properly Green LED Blink Short circuit or current overload OFF No...

Страница 9: ...ower cord Please make sure that 1 The power cord extension has a PE Protective Earth terminal Figure 6 Aka Equipment Grounding Conductor 2 The ground contact in the power outlet is securely connected...

Страница 10: ...C to DC UPS or solar powered DC backup UPS Once the DC power is connected the DC power functions as backup power If the AC is not used and the DC power is connected then the DC power functions as the...

Страница 11: ...Plug MUST be used to cover the Sealing Insert if any of the hole is not used in order to maintain waterproof of the connector Installation Mounting You can mount the system with one of the two ways 1...

Страница 12: ...can be order if required 1 Mast Pole Mounting Kit Part No MMK0001 2 SFP Duplex 1 25Gbps 3 3V Single Mode Transceiver Part No SFP SM LC20 DDM 3 SFP Duplex 1 25Gbps 3 3V Multimode Transceiver Part No SF...

Страница 13: ...Page 13 Product Specifications ELECTRICAL PIN OUT DIAGRAM...

Страница 14: ...om U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Customer Service and Orders S...

Отзывы: