Inscape Data AirEther AP11 Скачать руководство пользователя страница 4

 

Version 1.0.0 

1.4  Installing the Console Port Cable 

 

Step 2:

 Attach the Console Port cable to the Serial Port. Attach the other 

cable end to the Serial Port on a PC running a terminal emulation program, 
and set the terminal to 

115200 

Baud, 

No

-Parity, 

data bits, 

Stop bit, flow 

control(off), and ANSI compatible. 

NOTE: 

This connection is required for setting up initial configuration 

information. 
After configuration is completed, this cable may be removed until additional 
configuration is required via the Serial Port. 

 

1.5  Connecting the power supply and Ethernet 
cable 

 
Step 3

 

Plug the female end of the power cord into the Inline Power Injector, 

and then plug the male end of the power cord into a power outlet or power 
strip. The Power LED on the front of the Inline Power Injector will light up. 
 

Step 4

 

Run the cross over Ethernet cable (included in your package) from 

Data Input Port (on the front of the Inline Power Injector) to the Ethernet 
Port on the PC we mentioned above. 
 

NOTE: 

This connection is required for setting up initial configuration 

information. After configuration is completed, this cable will be removed, 
and then you should run an Ethernet cable from Data Input Port (on the 
front of the Inline Power Injector) to the LAN connection (such as a hub or 
switch). 
 

Step 5

 

Plug the MIL-C-5015 style Ethernet connector into the Special 

Ethernet port on the back of the access point. 
 

Step 6

 

Plug the RJ-45 Ethernet connector (the other end of the Special 

Ethernet cable) into the Power & Data Output Port on the front of the Inline 
Power Injector. When the Access Point receives power over the Ethernet 
cable, the Access Point will start its boot sequence and the Active LED on 
the front of the Inline Power Injector will light up. 
 
 

 

Version 1.0.0 

1.6  Outdoor Installation 

 
Outdoor Access Point device can be mounted on the side of a building 
or mounted to a mast as shown in following: 
 

 

 
A wall (side) mount allows for mounting of the Outdoor AP11 on the 
side of a building. This will provide a convenient mounting location 
when the roof overhang is not excessive and/or the location is high 
enough to provide a clear line of sight. 
 

Grounding 

 

A safety grounding system is necessary to protect your outdoor 
installation from lightning strikes and the build-up of static electricity. 
So direct grounding of the antenna mast, Outdoor AP11 and 
Surge Arrester is very important.

 

And so

 

mounting the Outdoor AP11 

on the antenna mast, you have to connect the Outdoor AP11 to the 
same grounding system with the AC wall outlet

.

 

The grounding system must comply with the National Electrical Code 
and safety standards that apply in your country. Always check with a 
qualified electrician if you are in doubt as to whether your outdoor 
installation is properly grounded. 

 

Содержание AirEther AP11

Страница 1: ...IP Ethernet connection 9 2 1 4 Wireless Access Router with static IP Ethernet connection 10 CHAPTER 3 INITIAL CONFIGURATION 11 3 1 CONFIGURE REQUIREMENTS 11 3 2 CONFIGURE THE AP11 13 3 2 1 Configure t...

Страница 2: ...r installing the AirEtherTM AP11 Outdoor Access Point 1 1 Before You Start After unpacking the system make sure the following items are present and in good condition 1 AirEther AP11 Access Point 2 Inl...

Страница 3: ...necting the Ethernet Cable to a Hub Switch Router or PC 5 6 4 Version 1 0 0 3 1 3 Installing the Antennas Step 1 With the unit powered off attach the dipole antenna to the antenna connector as shown i...

Страница 4: ...5 Plug the MIL C 5015 style Ethernet connector into the Special Ethernet port on the back of the access point Step 6 Plug the RJ 45 Ethernet connector the other end of the Special Ethernet cable into...

Страница 5: ...zed Access Point To show some possibilities of wireless topologies the following examples are provided 1 Wireless Access Bridge 2 Wireless Access Router with PPPoE Ethernet connection 3 Wireless Acces...

Страница 6: ...n the AirEther AP11 and assign IP address to PC1 PC2 and PC3 5 Set Wireless parameters on client stations PC1 PC2 and PC3 SSID wireless Version 1 0 0 9 2 1 3 Wireless Access Router with dynamic IP Eth...

Страница 7: ...er 4 3 1 Configure Requirements The AP11 is shipped with configuration that can be utilized right out of the box The default configuration is a bridge between an Ethernet and wireless network Administ...

Страница 8: ...ke to configure the AP11 please refer to the following procedures The web user interface can be grouped into Quick setup Basic Configuration Advanced Configuration and Utility as shown in Figure 3 3 T...

Страница 9: ...he AirEther AP11 as a Router with PPPoE Ethernet connection Configure TCP IP parameters 1 Click Advanced Config select Bridging and then click Disable for Bridge Function as shown in Figure 3 4 After...

Страница 10: ...ss network In interface 2 Make sure this Ethernet interface status is Active and specify the Ethernet IP address default is 192 168 2 1 and Ethernet Net Mask default is 255 255 255 0 of the Ethernet i...

Страница 11: ...ge specify the Default Route Default is 192 168 2 254 is 0 0 0 0 and then click FINISH button at the bottom of this page to complete the modification of this page Figure 3 9 5 Click Basic Config selec...

Страница 12: ...n as shown in Figure 3 4 After that click FINISH at the bottom of this page to complete the modification of this page 2 Click Basic Config select DHCP as shown in Figure 3 10 and make sure the DHCP cl...

Страница 13: ...in the WEP Key and specify which WEP Key you want to use Click FINISH at the bottom of this page to generate a WEP key and complete the modification of this page Note If you enable WEP services on AP1...

Страница 14: ...s User Information table Version 1 0 0 25 4 Some Radius server implements EAP authentication like Microsoft Windows 2000 server or Cisco ACS To set up the Radius server and AP11 for authentication you...

Страница 15: ...er service on Wireless or Ethernet interface 3 Click FINISH at the bottom of this page to complete the modification of this page Note The administrator must configure correct Gateway and DNS server ne...

Страница 16: ...at the bottom of PAT page to complete the modification for the Virtual Server Mapping Figure 3 15 Version 1 0 0 29 3 7 Configure Routing Table 1 Click Advance Config and select the Static Route page T...

Страница 17: ...can also click ADD DELETE MODIFY button to maintain this MAC address table 3 Click FINISH at the bottom of this page to complete the modification of this page Version 1 0 0 31 3 9 Configure SNMP 1 Cli...

Страница 18: ...present the current configuration settings the administrator has made 2 Click Basic Config or Advance Config and select the Save Restart page In this page as shown in Figure 3 20 you can click the SA...

Страница 19: ...3 20 Version 1 0 0 35 3 11 Utility 3 11 1 System Info Click Utility select System Info page as shown in Figure 3 21 you can view some system information on this such as Model Name Software Version CPU...

Страница 20: ...figuration The AP11 is designed to operate as shipped from the factory without any special set up However it has many options and parameters that can be changed if the needed arises Most of the manage...

Страница 21: ...or add The definition of the parameters is described in Table 4 1 to Table 4 14 Up Down or i k key move the cursor up down to the specific item Right or l or Enter key select the item or enter to sub...

Страница 22: ...ip User_profile name pass_set0 Version 1 0 0 41 Figure 4 4 Interface 1 address ip netmask link type Disable Ethernet attrib Disable Enable Global Virtual bridge Disable Enable 2 address ip netmask lin...

Страница 23: ...s set 1 3 isp profile ISP name destination string account profile name pass set 1 4 isp profile ISP name destination string account profile name pass set 1 Version 1 0 0 43 Figure 4 4 dhcp service Dis...

Страница 24: ...1 0 0 45 Figure 4 4 Show Show the current configuration values interface PPP ip _ share dhcp snmp bridge isp run reset default write reboot su sys info Ping ip 1 65534 t 1 1999 exit configuration max...

Страница 25: ...s Dimensions 245 L mm x 200 W mm x 70 H mm Weight 2100 g Version 1 0 0 47 Chapter 6 Default Settings B 1 Basic Configuration B 1 1 System as shown in Table B 1 Parameter Description Default Value Supe...

Страница 26: ...thentication protocol for the corresponding dial in interface None Table B 2 Version 1 0 0 49 B 1 3 Telnet Console as shown in Table B 3 Parameter Description Default Value Maximum User Set the maximu...

Страница 27: ...efault Value Service Name Specify the service for public access NULL Protocol Select a protocol for public access NULL Public Access Select an interface for public NULL Version 1 0 0 51 Interface acce...

Страница 28: ...e each key must consist of hex digits it means that only digit 0 9 and letters A F are valid entries If entered incorrectly program will not write keys to a driver Table B 8 Version 1 0 0 53 B 1 9 Bri...

Страница 29: ...e or disable the activity of the corresponding community Enable Version Select or disable the SNMP Version Version 1 MIB1 Version 2 MIB2 Version1 IP Address Specify the IP address of the SNMP Manager...

Страница 30: ...equipment off and on the administrator is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation bet...

Страница 31: ...following technical standards EN 300 328 2 EN 301 489 1 EN 301 489 17 EN 60950 Marking by the symbol Indicates compliance with the essential requirements of R TTE Directive 99 5 EC and the product is...

Отзывы: