Double pulse switching test

Run a double pulse test on the channel under test.  Use half the nominal DC-bus voltage at fi rst. Once that 
is okay, repeat the test with the nominal DC-bus voltage.

Make sure to capture the input and output signals on the oscilloscope and save the images. If something 
does not seem right, stop the test straight away and check for the reason!

Once these tests have been successful, turn off  the DC-bus supply and wait until the DC-bus has COMPLETELY 
DISCHARGED. Then turn off  the low voltage supply to the driver.

Normal switching test

Connect the application controller to the input of the driver. Make sure all the connections are correct, no 
wires inter-changed, all the bolts are still tight and no conductive materials or swarf is interfering with the 
required clearance and creepage distances

Now the full switching test can be conducted.

Proceed by turning on the low voltage supply to the driver and then slowly turning up the DC-bus voltage 
as with the pre-test. If something does not seem right, stop the test straight away and check for the reason! 
If there has been an incorrect connection, make sure the driver is not damaged!

Once the nominal DC-bus voltage is present, turn on the controller, thereby applying the application 
switching signals. Make sure to capture the input and output signals on the oscilloscope and save the 
images.

If all is well, you have got the system working correctly. If something does not seem right, stop the test 
straight away and check for the reason!

The voltage and current waveforms may not precisely look like the expected result. This will be due to 
specifi cs of the inverter design such as stray or leakage inductances and bus-bar or cable runs.

Short circuit test

If the results you have achieved so far are of suffi

  cient quality, you can proceed with the short circuit 

tests.

This is carried out just like the double pulse test described above, except with a short circuit applied at the 
appropriate terminals.

Again start with half the nominal DC-bus voltage. Due to the fact that much higher currents can be 
expected with this test, take extreme caution in protecting all personnel and equipment from inadvertent 
action or explosion!

Finally use the full nominal DC-bus voltage and repeat the test, capturing the signals on the oscilloscope.

Re-programming of the IPS driver

To get the driver tuned to the optimum result, it may require the IPS application support. Please forward 
the scope images to IPS together with any relevant information on the application test.

The engineering team of the InPower Systems will evaluate your tests results and send you a re-programming 
software tuned exactly to the real conditions of your inverter.

NOTE: We can only retune the driver according to your real conditions if we receive from you all relevant 
information of your inverter including tests results.

Содержание 1IPSE1A33-60

Страница 1: ...E1A33 60 FOR MEDIUM AND HIGH POWER IGBTS M A N U A L InPower Systems GmbH Am Kornfeld 11 D 86932 P rgen Germany Tel 49 0 8196 93000 Fax 49 0 8196 930020 Email info inpower sys com VAT Id DE 221021830...

Страница 2: ...m i n a r y 2 TABLE OF CONTENTS 1 SAFETY NOTICE 3 2 HANDLING AND MOUNTING ADVICES 4 3 MAIN FEATURES 5 4 MECHANICAL DIMENSIONS 5 5 KEY DATA 6 6 INTERFACES 6 7 COMMISSIONING SUPPORT 7 8 INPUTS AND OUTPU...

Страница 3: ...te handling or transport Contact while uninstalled is permitted only with ESD protection Install only without supply voltage Use only suitable electronic devices Always keep sufficient safety distance...

Страница 4: ...not exceed 30cm Max length of simple cable should not exceed 7cm For the gate and auxiliary emitter connections it is recommended to use coaxial cable RG58 C U with auxiliary emitter connected to the...

Страница 5: ...er current in all short circuit conditions over voltage during turn off Advanced control and protection functions four level desaturation monitoring two level di dt monitoring feedback clamping with a...

Страница 6: ...rage temperature TST 40 to 85 C Input driving and output error signal optical 660nm Turn on delay time tpdON 400nsec Turn off delay time tpdOFF 400nsec Typical time of soft shut down tSSD 1 2 sec Max...

Страница 7: ...n the DC low voltage supply for the driver Make sure that there is no strange noise smell heat or otherwise originating from the driver The voltage supply LEDs should now light up green which means th...

Страница 8: ...capture the input and output signals on the oscilloscope and save the images If all is well you have got the system working correctly If something does not seem right stop the test straight away and c...

Страница 9: ...nting holes for M4 screws It is possible to use plastic or metal screws Mounting holes have different potentials The auxiliary adaptation board is including an addi tional gate capacitor C3 C2 or C1 i...

Страница 10: ...le connector Driver with cable connector Max length of coaxial cable 40cm For gate and auxiliary emitter connections use coaxial cable RG58 C U with auxiliary emitter connected to the shielding For po...

Страница 11: ...ons use coaxial cable RG58 C U with auxiliary emitter connected to the shielding For power emitter and auxiliary collector it is recommended to use HV isolation cable for instance Radox 9 GKW AX 1 5mm...

Страница 12: ...minal operation red light U sat 1 protection was operating U sat 2 D 17 no light system is working in nominal operation red light U sat 2 protection was operating U sat 3 D 18 no light system is worki...

Страница 13: ...e described hardware has been checked Discrepancies may exist nevertheless no guaranty is assumed for total congruence The information contained in this document is subject to regular revision Any alt...

Отзывы: