background image

 

 

Installation 

INOXPA S.A.U.

 

20.005.30.01EN · (0) 2019/02 

 

11

 

5.6.  ASSEMBLY 

To  locate  and  fix the agitator  in  the support flange of the tank, the propeller must be  removed from the  shaft. 
Once the base of the agitator is placed on the supporting flange, the fixing nuts and screws will be assembled in 
their corresponding holes, without being tightened. When this operation has been carried out, the agitator must 
be levelled using the following method: 

1.  Place a spirit level against the shaft. 
2.  Check 4 points at 90º to each other around the circumference of the shaft and at the same height. 
3.  Once the shaft is level, firmly tighten the fixing nuts and screws. Finally the propeller is mounted on the 

end of the shaft. Be careful when assembling the shaft not to hit or strain it so as to avoid it being bent. 
 

 

 

Force  should  never  be  applied  to  the  end  of  the  agitator  shaft,  as  it  can  easily  suffer  permanent 
damage. 

 

 

 

Check the alignment of the agitator shaft with the half shaft once its assembly is completed. 

 

 

 

ATTENTION 

ATTENTION 

Содержание BCI Series

Страница 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS VERTICAL AGITATOR BCI Original Manual 20 005 30 01EN 0 2019 02 20 005 32 0010...

Страница 2: ...ical agitator From serial number IXXXXXX to IXXXXXX 1 XXXXXXXXXIIN to XXXXXXXXXIIN 1 Fulfills all the relevant provisions of the following directive Machinery Directive 2006 42 EC Low Voltage Directiv...

Страница 3: ...5 Installation 5 1 Reception of the agitator 8 5 2 Identification of the agitator 8 5 3 Transport and storage 9 5 4 Location 10 5 5 Electrical installation 10 5 6 Assembly 11 6 Start up 7 Troubleshoot...

Страница 4: ...bstances released 2 3 WARRANTY Any warranty will be void immediately and lawfully and additionally INOXPA will be compensated for any civil liability claims submitted by third parties in the following...

Страница 5: ...pray directly on the engine Do not disassemble the agitator until the switchboard has been disconnected Remove the fuses and disconnect the power cable supplying the motor All electric work should be...

Страница 6: ...ks The maximum operating conditions of the agitator should not be exceeded Nor should the operating parameters for which the agitator was initially designed be modified without written authorisations...

Страница 7: ...the surface of the product along the walls of the tank The effect is promoted if the bottom of the tank is curved The Lineflux vigorously agitates the content of the tank promoting the mixing of the...

Страница 8: ...te INOXPA packs the agitators in their fully assembled form or disassembled on a case by case basis Ensure that the agitator has not been damaged in any way If it is not in good condition and or any p...

Страница 9: ...3 TRANSPORT AND STORAGE According to the model the agitators are too heavy to be stored or installed manually Use an appropriate mode of transport Do not handle the agitator by the shaft as this may...

Страница 10: ...d the next table 5 5 ELECTRICAL INSTALLATION Before connecting the electrical motor to the mains check local regulations on electrical safety as well as the applicable standards Check the instructions...

Страница 11: ...velled using the following method 1 Place a spirit level against the shaft 2 Check 4 points at 90 to each other around the circumference of the shaft and at the same height 3 Once the shaft is level f...

Страница 12: ...e filling or emptying of the tank The agitator can NEVER operate without fluid The agitation elements may only be submerged to a height equal to 1 5 times its diameter All the guards must be in place...

Страница 13: ...the agitator is mounted Mechanical risks e g drag shear cutting impact flattening and pinching If the agitation element is accessible from the top or the tank inspections hatch then the user will be...

Страница 14: ...y heating the liquid High density Increase motor power Tank too big for the chosen agitator Check with the technical department Wrong direction of rotation Change direction of rotation Agitator speed...

Страница 15: ...gear motor maintenance shall be carried out in accordance with the manufacturer s instructions see the instructions manual 8 3 LUBRICATION The BCI vertical agitators are mounted on permanently grease...

Страница 16: ...IEC motor 93 Release the elastic ring 66 with appropriate pliers Hit the lower end of the head half shaft 26 with a nylon hammer and take out the unit formed by the head half shaft and the ball bearin...

Страница 17: ...iner NBR Bearing support Aluminium 9 2 OTHER FEATURES Motor IEC B14 IP 55 F class insulation Speed rpm 1500 Motor power kW 0 75 kW Shaft length mm 1250 max Shaft diameter mm 16 Propeller diameter mm 1...

Страница 18: ...30 01EN 0 2019 02 9 4 DIMENSIONS Type agitator Agitator shaft A B C BCI1 18 4007 1 100 100 1 610 160 BCI1 18 4007 1 130 130 1 610 160 BCI1 18 4007 1 150 150 1 610 160 BCI1 18 6005 1 130 130 1 610 160...

Страница 19: ...316L 05 Agitator shaft 1 AISI 316L 06 Head 1 Aluminium 26 Head half shaft 1 AISI 316L 42 Base plate 1 AISI 316L 50 Countersunk screw 4 A2 51 Allen screw 4 A2 53 Flat washer 4 A2 55 Allen pin 2 A2 55A...

Страница 20: ...nyoles Spain Tel 34 972 575 200 Fax 34 972 575 502 How to contact INOXPA S A U Contact details for all countries are continually updated on our website Please visit www inoxpa com to access the inform...