![Inovonics 525N Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/inovonics/525n/525n_installation-and-user-manual_2064834025.webp)
— —
21
condition used by the Web interface to dispatch text-message
or email notifications to specific recipients. (This notification
procedure is explained on Page 40.)
The rear-panel tally closure, on the other hand, can either fol-
low the alarm criteria just described, or it can respond instan-
taneously to either red LED front-panel flasher. (If, for exam-
ple, you wanted to have a remote flasher in your office.) Use
the
SEL
buttons to bracket
CLOSURE:
, and then set it either to
ALARM
or to
PEAK FLASHER
with the
MENU/EDIT
buttons.
The polarity of the
OVERMODULATION
alarm closure (open or
ground) is set through Menu No. 8,
CLOSURE POLARITY
, dis-
cussed a bit farther along.
SETTING THE LOW SIGNAL ALARM
The 525N gives a front-panel alarm, a rear-panel tally output,
and can dispatch email or text messages in a ‘carrier loss’ situ-
ation, defined as a drop in carrier level below a preset trip
point for a preset number of seconds. Bring up Menu No. 5,
SET LOW SIGNAL
.
Alarm Trip
Point
With the
SET LOW SIGNAL
screen up as shown, press
SEL
but-
tons to navigate among the fields that can be edited. As you
cycle the
SEL
buttons, you will see that blinking brackets ap-
pear around any number that can be changed.
First, position the brackets around the
TRIP LEVEL:
value,
35dBuV
in the example. Next, use
MENU/EDIT
buttons to set
the value to whatever figure you decide. Depending on the in-
coming carrier level displayed on the
SIGNAL AND NOISE
screen, you would set the alarm trip point somewhere below
the
RSSI:
value of the carrier. An alarm trip point about 10dB
below the
RSSI:
value might be a good starting point, but you
may need to factor-in normal variations in signal strength from
propagation and fading effects, depending on the distance be-
tween the 525N and your transmitter site. Also, be sure to
keep the
TRIP LEVEL:
above residual noise at the receive fre-
quency when the carrier is off. And, of course, make any al-
lowance for a different nighttime power setting if the station’s
power reduces after dark.