background image

12  

64 & 

over  

13.7 & 

over  

45 & over 

Hurricane   

Air filled with foam; sea completely white with 

driving spray; visibility greatly reduced   

 

(Reference table based on observations of the effects of the wind) 

 

 

 

12/ WIND CHILL 

 

Wind chill is the apparent temperature felt on exposed skin due to the combination of air temperature and wind 
speed. The wind chill reading on the monitor is calculated based on the temperature measured from the 
anemometer (channel-1) and the average wind speed.   

   

13/ GUST WIND & WIND CHILL ALARM

 

High Gust Wind Alarm 

 

You can set the monitor to sound an alarm for about 1 minute when gust wind reaches or exceeds a set limit. 
Press “WIND ALARM” to silence the alarm sound. The related high alarm icons will continue to flash until the 
alarm condition is no longer met.   
   

High Gust Wind Alarm Setting: 

 

 

- Press “WIND ALARM” to show high gust wind alarm display. “ALARM” icons appear in the gust wind 
display area   

 

- Hold “WIND ALARM” button to enter its setting mode and gust wind digits will flash   

 

- Press “

”or “

” to set the value   

 

- Press “WIND ALARM” to confirm setting and exit   

 
Press “WIND AL   ” repeatedly to enable or disable the gust alarm. “

  ” appears when it is enabled.     

 

Low Wind Chill Alarm 

 

You can also set the monitor to sound an alarm for about 1 minute when the wind chill reaches or falls below the 
set limit. Press “WIND ALARM” to silence the alarm sound. The related low alarm icon will continue to flash until 
the alarm condition is no longer met.   
 

Low Wind Chill Alarm Setting: 

 

 

- Press “WIND ALARM” repeatedly so “ALARM” icons appear in the wind chill display area   

 

- Hold “WIND ALARM” button to enter its setting mode and the wind chill digits will flash   

 

- Press “

”or “

” to set the value   

 

- Press “WIND ALARM” to confirm setting and exit   

 
Press “WIND AL   ” repeatedly to enable or disable the wind chill alarm. “

  ” appears when it is enabled.     

   

14/ MAXIMUM & MINIMUM RECORDS 

 

Press “MEMORY” repeatedly to view the maximum & minimum values of temperature, humidity, heat index, dew 
point, wind speed & wind chill readings. The corresponding “MAX” and “MIN” icons will appear. To clear the 
memory record, hold “MEMORY” in the max/min display mode   
   

15/ RADIO-CONTROLLED CLOCK 

 

The unit will start synchronizing the radio-controlled clock after battery/adapter installation. The antenna icon will 
flash during synchronization. If the reception of radio-controlled time is successful, antenna icon with full signal 

strength 

    will appear on screen. The radio-controlled clock will have a daily synchronization at 02:03 & 03:03 

everyday. Each reception cycle is around 2.5 to 10 minutes.   

                             

   

               

   

           

   

Antenna icon 

disappear  

Searching for Radio-Controlled Clock 

Signal  

Reception is 

successful 

Reception is 

fail  

Reception is disabled 

 
   
Antenna icon without signal strength indicates the past reception is not successful (Daily synchronization is still 
enabled). To enforce searching of radio-controlled time signal immediately, press 

  repeatedly until the antenna 

Содержание SM55PRO

Страница 1: ...rewdriver Hexagonal Key Electric drill Pencil Level Mast 1 1 25 inch 2 54 3 18 cm in diameter to mount the anemometer 1 INSTALLATION The weather station operates at 433MHz and does not require wire in...

Страница 2: ...thin 10 minutes the RF transmission is successful and the anemometer monitor are within the effective transmission If above readings are not shown after 10 minutes of searching the transmission is fai...

Страница 3: ...so it is pointing due north 3 Hold the wind vane pointing due north and do not allow it to turn Insert 2 pieces of AA batteries according to the polarity indicated The red LED indicator above the bat...

Страница 4: ...eplace lock the rain gauge cover on the base 5 Hold CHANNEL SEARCH button on the monitor for 3 seconds and the total rainfall will flash The monitor is now searching for all remote sensors Total rainf...

Страница 5: ...ity data to the monitor Then close the battery door and tighten the screws 5 Hold CHANNEL SEARCH button on the monitor to search for all remote sensors The temperature humidity readings of your select...

Страница 6: ...eset or during battery replacement Searching mode display Wind direction temperature humidity information will flash RF Connection completed Valid wind speed direction Ch 1 temperature humidity readin...

Страница 7: ...rt for possible icy road condition to driver 7 IN OUT HEAT INDEX Heat Index combines the effects of heat and humidity It is the apparent temperature of how hot the heat humidity combination makes it f...

Страница 8: ...and so on Press WIND to select gust average wind speed display Wind direction Average wind direction over a 2 minute period Average wind speed Average wind speed over a 2 minute period Gust wind speed...

Страница 9: ...sound The related low alarm icon will continue to flash until the alarm condition is no longer met Low Wind Chill Alarm Setting Press WIND ALARM repeatedly so ALARM icons appear in the wind chill dis...

Страница 10: ...s connected to the monitor it will provide continuous backlight to the display Press SNOOZE LIGHT for an extended backlight if adapter is not connected 20 LOW BATTERY INDICATION Low battery indication...

Страница 11: ...e Resolution 0 1 degree C Indoor Outdoor Humidity 20 99 RH Humidity Resolution 1 RH Channel for Temp Humidity maximum 3 Wind speed range 0 30m s 0 108 km h 0 67 mph 0 58 3 knot 0 11 Beaufort Rain Gaug...

Страница 12: ......

Отзывы: