2. - day/night mode switching 

 

3. - send image if contact is switched on / automatic gate control 

 

4. - relay 2 switch off when door opening 

 

5. - time switching mode of relay 2 control 

 

6. - always switch off relay 2 when pushbutton is pressed 

 

7. - always switch on relay 2 when pushbutton in night mode is pressed 

 

8. - always switch on relay 2 when contact is switched on  

8. - device identification (x - parameter number): 
 

1. -  

 

2. -  

 

3. - send attendance data to server over radio 

 

4.  - 

 

5. - device identification after turn on over IP 

 

6. - device identification after turn on over data call 

 

7. - device identification after turn on over SMS 

 

8. - active connection to server over IP  

9. - type of mode (day / night) in Sunday and Saturday (x - parameter number): 
 

1. - night mode 

 

2. - fixed setting (if not - setting is by switching time) 

10. - relay 2 switch-on time - hour : minute 
12. - relay 2 switch-off time - hour : minute 
14. - led pushbuttons turn-on time - hour : minute 
16. - led pushbuttons turn-off time - hour : minute 
18. - day mode switching time zone1 - hour : minute 
20. - night mode switching time zone1 - hour : minute 
22. - day mode switching time zone2 - hour : minute 
24. - night mode switching time zone2 - hour : minute 
26. - 29. - server IP address 
30. - 31. - server port 
32. - 47. - IP provider APN - for internet access 
48. - 54. - own telephone GSM number 
55. - 61. - GSM tel. number of PbX (two - step dial) 
62. - 68. - GSM tel. number of server (CLIP) - IP connection to server after  
 

       incoming call 

69. - 75. - GSM tel. number of server - for data call to server 
 

5.3 Table of GSM parameters 

 
0. - speaker volume (value: 0 - 100) 
1. - ringing volume (value: 0 - 4) 
2. - microphone sensitivity (value: 0 - 15) 
3. - echo suppression (value: 0 – 8) 
4. - selective echo suppression (value: 0 – 6) 
5. - echo suppression on/off 
6. - 9. - SIM pin code 
10. - number of digits of identification prefix in international format 

 
5.4 Table of analogue line parameters 

 
0. – type of tone detection (ringing, call,…) 

Содержание Anthrocite ST

Страница 1: ...OR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION GSM GSM GSM GSM ANALOG ANALOG ANALOG ANALOG DOOR ENTRY DOOR ENTRY DOOR ENTRY DOOR ENTRY PHONE PHONE PHONE...

Страница 2: ...Table of analogue line parameters 5 5 Table of radio parameters 5 6 Table of RFID parameters 5 7 Table of camera parameters 5 8 Table of pushbutton codes 5 9 Table of numbers for 16 pushbuttons day m...

Страница 3: ...rmware upgrade 10 Installation and setting up 11 Diagnostics 12 Technical parameters 12 1 Electrical parameters 12 2 Mechanical parameters 13 Operating environment 14 HW configuration and ordering 15...

Страница 4: ...by calling from GSM door entry station to mobile phone fixed line or PbX call can be operated via GSM or analog line for calling through GSM GSM there is possibility of two step dial with dtmf dial w...

Страница 5: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION...

Страница 6: ...tless Mifare cards reader automatic PCB heating when installed in cold environment radio in band 433 or 868 MHz external radio 10BT Ethernet converter for transfer of images attendance data or remotel...

Страница 7: ...Each pushbutton press is signalized by acoustic signal For analog line the call release can not be reliably evaluated and therefore the call is ended either if preset max time expires or door is open...

Страница 8: ...1 attendance arrival 2 interruption departure 3 interruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival or other customer codes total number of types is max 1...

Страница 9: ...the pushbuttons led illumination based on set time Moreover it is possible to set automatic device identification after turning on by sending its serial number and mobile phone number to server over s...

Страница 10: ...remote upgrade firmware via GSM network is unsuccessful only locally way by USB after turn off is able Configuration SW uses graphic mode Configurations data can be saved to PC Configuration SW contai...

Страница 11: ...ation serial number production date device type hardware configuration radio band 433 or 868 MHz 5 2 Table of basic configuration 0 waiting time period for between individual presses of pushbuttons 10...

Страница 12: ...fixed setting if not setting is by switching time 10 relay 2 switch on time hour minute 12 relay 2 switch off time hour minute 14 led pushbuttons turn on time hour minute 16 led pushbuttons turn off t...

Страница 13: ...value 0 7 3 data baud rate value 0 13 35kbps 100kbps step 5kbps 4 radio output power value 0 7 1dB 20dB step 3dB 5 6 Table of RFID parameters 0 contactless card reader mode only ISO 14443A available...

Страница 14: ...same as for day mode 5 11 Table of calling groups day mode 1 max 3 numbers one number max 14 digits number can also represent number of overflow group 2 parameters for each number 3 two step dial for...

Страница 15: ...5535 5 17 Table of alarm alerts 1 alarm type 0 door opened for long time 1 entrance without identification 2 incorrect identification code 3 power supply drop out 4 contact switched on 5 SIM is remove...

Страница 16: ...e parameter for example 2 8 4 set group 4 for pushbutton 8 in night mode FUNC3 change of numbers of group day mode 3 group number tel number parameter tel number parameter max 3 note tel number can be...

Страница 17: ...C17 radio reset 17 FUNC18 rfid reset 18 FUNC19 set night mode 19 FUNC20 set day mode 20 7 Programming of contactless Mifare RFID cards Contactless cards can be programmed to device in programming mode...

Страница 18: ...er option how to set the registration numbers or parameters after first programming of cards is to edit this data using configuration software in the same order as individual cards were scanned This p...

Страница 19: ...SYSTEMS FOR VOICE AND DATA COMMUNICATION GSM GSM GSM GSM ANALOG DOOR ANALOG DOOR ANALOG DOOR ANALOG DOOR PHONE STATION PHONE STATION PHONE STATION PHONE STATION 8 Configuration software...

Страница 20: ...anged In this state it is not possible to configure the device only after time is overflow remotely central over USB GSM converter by data connection M2M to GSM door entry phone station over mobile ne...

Страница 21: ...ctrostatic discharge 2 After mechanical mounting of unit connect the cables power supply 12V DC relay contacts contact sensors expander box with 12 pushbuttons Before connecting the power supply as we...

Страница 22: ...entre after its turning on power supply connection by sending its serial number and mobile phone number to server over pre set interface Device enables the diagnostics that means via USB interface to...

Страница 23: ...quency detect bandwidth 2 2 DTMF detect response time 40ms DTMF pause length detected 30ms RFID 13 56MHz HF RFID reader ISO 14443A and B in this firmware only 14443A output power up to 500mW Radio fre...

Страница 24: ...ns The product was shop checked The producer guarantees that this product will keep the features described in these operating instructions in the course of guarantee provided that the user will be han...

Страница 25: ...3 or 868 MHz It uses TCP IP protocol in application client server With another firmware it can also be used as radio repeater To process attendance data and images from camera external application sof...

Страница 26: ...ation door entry phone station radio parameters have to be same as in door entry phone station Firmware can to be changed by using TFTP protocol After turn on the device bootloader is running short ti...

Страница 27: ...has to be set as in GSM door entry station Remote radio control unit is powered by internal 3V LION battery 17 1 Technical parameters Battery 3V CR2032 Radio 240 930 MHz FSK GFSK and OOK modulation m...

Страница 28: ...erruption arrival 4 business departure 5 business arrival 6 doctor departure 7 doctor arrival Function attendance type and employee registration number is transmitted after pressing the pushbutton Not...

Отзывы: