Page 11
EN
Chapter 4 Assembly and function
NOTE
Note the optimum assembly sequence.
1. Assemble the pump unit (rotor/stator/pressure gauge)
with both tie rods at the lower end of the yellow mixing
zone.
2. Open the eccentric lock on the motor and move it away
to the side. Push the mixing coil into the material hop-
per. Then move the motor back again and close the
eccentric lock. Ensure that the mixing coil is connected
to the motor and rotor of the pump unit via the motor
bracket.
3. In case you are using a compressor, connect the yellow air
hose to the compressor and plug the power cable into the
upper right socket on the switching cabinet.
4. In case you are using a booster pump, plug the power
cable into the upper left socket on the switching cab-
inet.
5. Connect the input socket to the external power supply
(230 V / 16 Hz)
4.4 Components
7
2
3
4
5
6
1
4.4.1 Description of the components
Item
Component
1
Frame with wheels, material hopper and
mixing zone incl. mixing coil
2
Pump unit (rotor / stator / mortar pressure
gauge)
3
Motor
4
Switching cabinet
5
Air fitting
6
Water fitting
7
Compressor (optional)
4.4.1.1 Frame with material hopper, mixing pipe incl.
mixing coil and wheels
The material hopper, switching cabinet and air and water
fittings are assembled on the frame. The pump unit, mixing
zone and motor are attached to the material hopper. The
mixing coil is pushed into the material hopper with the mo-
tor opened after the pump unit has been attached to the
yellow mixing zone by two tie rods.
Material hopper with hopper mesh and toothed rail
4.4.1.2 Pump unit (rotor / stator)
Depending on the area of application, various rotors and
stators are used (see accessories).
4.4.1.3 Motor
The motor is attached to the material hopper by an eccen-
tric lock. The power supply for the motor is permanently
installed.
4.4.1.4 Switching cabinet
All the necessary connections and controls for operating the
machine are located on the switching cabinet. It is firmly
screwed to the frame of the machine. The switching cabinet
can be removed from the frame for maintenance and repair
work.
Connect the power supply plug on the switching cabinet to
the external power supply (230 V / 50 Hz). The cross-section
of the supply cable must be at least 2.5 mm
2
! The inoMIX
inoCOMB Picco Power may only be run with an approved FI
circuit breaker (30 mA) (RCD), e.g. with the INOTEC PRCD-S
personal protection switch (item no. 10015278).
4.4.1.5 Water fitting
The water fitting is attached to the frame. The optimum
water supply quantity is set by opening and closing the nee-
dle valve.
4.4.1.6 Air fitting
The air fitting is attached to the frame at the rear of the
switching cabinet. It can be connected to any commercially
available 230 V compressor.
4.4.1.7 Compressor (optional)
A compressor will be required if the mixing pump is to be
used for spray applications.
Содержание inoCOMB Picco Power
Страница 41: ...Page 41 EN Chapter 13 Systems 13 3 Circuit diagram for compressor...
Страница 42: ...Page 42 EN Chapter 13 Systems 13 3 1 Circuit diagram for mixer motor safety switch...
Страница 43: ...Page 43 EN Chapter 13 Systems 13 3 2 Circuit diagram for water pressure switch air pressure switch...
Страница 44: ...Page 44 EN Chapter 13 Systems 13 3 3 Circuit diagram for pump rotation speed...
Страница 45: ...Page 45 EN Chapter 13 Systems 13 3 4 Switching cabinet subplate inside...