12.INLET PRESSURE CONTROL
In order to measure the gas inlet pressure , a pressure gauge with a precision of
minimum 0,2 mbars should be used.
Remove the front control panel and the bolt “B” on the gas tap. Install the pressure
gauge here.
Turn on the burner and measure the inlet pressure. The measured value must be
suitable to the table “T4”. If not, then contact the authorized service.
Remove the pressure gauge and reinstall the bolt “B”.
13.OPERATION CONTROL OF THE GAS COMPONENTS
Check the screw adjustments of the gas tap and the cycle adjustment of the blowing
motor according to the user’s manual .
The adjustments of the fan rotation of the blowing motor should be realized as per
gas type, equipment type and combustion chamber and also the amount adjustment of
gas flow and the emission of chimney gas checks on gas valve , suitable to the
emission values of chimney gas, must be realized.
The procedures of emission of chimney gas should be realized for each combustion
chamber seperately. The measurements should be realized for the selected combustion
chamber while the oven door open and full (maximum) combustion is selected.
If necessary please see the below chapter “Possible Problems and Solutions ”.
14.USERS INSTRUCTIONS :
-
The equipment is designed for professional usage and must be operated by only
people who are trained about it.
- The control of the equipment is performed by buttons on the digital display .
- A new insulation material which reduces the heat loss to minimum and at the same
time eco- friendly is used .
- As an accessory, it is equipped with a trolley that fits in the oven .