12.INLET PRESSURE  CONTROL

In  order  to  measure  the  gas  inlet  pressure  ,  a  pressure  gauge  with  a  precision  of
minimum 0,2 mbars  should be used.
Remove the front control panel and the  bolt “B” on the gas tap. Install the pressure
gauge here.
Turn  on  the  burner    and  measure  the  inlet  pressure.    The  measured  value  must  be
suitable to the table “T4”. If not, then contact the authorized service.
Remove the pressure gauge  and reinstall the  bolt “B”.

13.OPERATION CONTROL OF THE GAS COMPONENTS

Check  the  screw  adjustments  of  the  gas  tap  and the cycle adjustment of the blowing
motor  according to the user’s manual .
The adjustments of  the fan rotation of the blowing motor  should be realized as per
gas type, equipment type and combustion chamber  and  also the amount adjustment of
gas  flow    and  the  emission  of  chimney  gas  checks  on  gas  valve  ,  suitable  to  the
emission  values of  chimney gas,  must be realized.
The procedures of emission of chimney gas  should be realized  for each combustion
chamber seperately. The measurements should be realized for the selected combustion
chamber  while the oven door open and full (maximum) combustion is selected.

If necessary please see the below chapter “Possible Problems and Solutions ”.

14.USERS  INSTRUCTIONS :

-

The  equipment  is  designed  for  professional  usage    and  must  be  operated  by  only

people who are trained about it.
- The control of the equipment is performed by buttons on the digital display .
- A new insulation material  which reduces the heat loss to minimum and at the same
time eco- friendly  is used .
- As an accessory, it is equipped with a trolley  that fits in the oven .

Содержание inosmart FKG10

Страница 1: ...1 KULLANIM KILAVUZU TR USER S MANUAL GB GAZLI KONVEKS YONLU FIRIN GAS CONVECTION OVEN MODEL FKG10 FKG20 FKG40 Revizyon No 00 Y r rl l k Tarihi 13 10 2022...

Страница 2: ...anesi ve hava da t m perdesi sayesinde homojen pi irme sa lar Sayg lar m zla NOKSAN A lk kurulum tarihinden itibaren 24 ay s reyle sizlere garanti hizmeti sunuyoruz Bunun i in garanti ba vurusunun do...

Страница 3: ...NIMINA Y NEL K UYARILAR 14 MONTAJ 14 9 SU BA LANTISI 14 10 ELEKTR K BA LANTISI 14 11 GAZ BA LANTISI 15 12 FARKLI GAZLARA EVR M 15 ISIL G KONTROL 15 13 G R BASINCI KONTROL 15 14 GAZ PAR ALARIN ALI MA K...

Страница 4: ...32 31 WATER CONNECTION 32 32 ELECTRIC CONNECTION 32 33 GAS CONNECTION 33 34 CONVERSION TO THE DIFFERENT GASES 33 THERMAL POWER CONTROL 33 35 INLET PRESSURE CONTROL 34 36 OPERATION CONTROL OF THE GAS C...

Страница 5: ...5 1 P KTOGRAM A IKLAMALARI...

Страница 6: ...6 2 R N G R N LER INO FKG10 INO FKG 20...

Страница 7: ...7 INO FKG 40...

Страница 8: ...elektrik enerjisini cihaza veriniz Panel zerindeki ON OFF butonuna basarak cihaz enerjilendirilerek a lmas sa lan r ON OFF BUTONU F r n kontrol panelinin a l p kapanmas n sa lar F r n ON konumunda ye...

Страница 9: ...r d ebilir veya pi irme kabininden d ar ya ta abilir Yanma tehlikesi Hatal montaj hatal servis bak m hatal temizleme veya cihazda yap lacak de i iklikler sonucunda cihaz ar zaya yaralanmalara ya da l...

Страница 10: ...su zerini kapatacak ekilde hi bir malzeme koymay n At k gaz zehirlenmesi Yang n Tehlikesi Cihaz n alt ve veya st k s mlar n e ya ile kapatmay n z Buralar n bo olmas n sa lay n z Kaplar s v yada pi irm...

Страница 11: ...1190 1190 Gaz Giri i Gas Inlet Entrada de gas in 3 4 3 4 3 4 Su Bas nc Water Pressure bar 2 4 2 4 2 4 Su Giri i Water Inlet Presi n de agua in 3 4 3 4 3 4 Fan Motor G c Fan Motor Rating Entrada de ag...

Страница 12: ...xhaust flow are given in the table below DAVLUMBAZ BACA VE METREK P CETVEL DUVAR T P DAVLUMBAZ F LTRES Z HOOD CHIMNEY AND METERCUBE SCHEDULE WALL TYPE HOOD WITHOUT FILTER FIRIN T P OVEN TYPE L W H M m...

Страница 13: ...13 7 LEV PAR ALARI F r n n b l mleri...

Страница 14: ...d r Cihaz yerle tirirken y kleme ve bo altman n rahat yap labilmesi i in f r n kap s n n en az 110 a labilecek ekilde olmas na dikkat ediniz 9 SU BA LANTISI Cihaz su giri ine 3 4 tesisat ekiniz ve uyg...

Страница 15: ...n kontrol ediniz E er de ilse Farkl Gazlara evrim b l m ne bak n z T m ba lant lar yap ld ktan sonra ba lant noktalar nda gaz ka ak kontrol yap n z 12 FARKLI GAZLARA EVR M Cihaz 20mbar NG G20 gaz yla...

Страница 16: ...E er gerekirse a a daki Olas Problemler ve z mleri k sm na bak n z 15 KULLANICI TAL MATI Cihaz profesyonel kullan m i in tasarlanm t r ve sadece bu konuda e itim alm ki iler taraf ndan kullan lmal d r...

Страница 17: ...da kullan labilecek olan GN2 1 60 65mm tepsilerde her tepside 60 porsiyon yemek bulunmakta ve bir seferde 10 tepsi f r nland nda 600 porsiyon yemek al nabilmektedir Cihazda pi irece iniz r n f r na ko...

Страница 18: ...utonu vas tas ile buhar p sk rterek r n n nemlendirilerek kurumas ve kabukla mas nlenmelidir Tepsileri f r n arabas na yerle tirirken ayn hizada olmas na ve tepsilerin tam olarak f r n raylar sonuna k...

Страница 19: ...19 16 GENEL G R N M...

Страница 20: ...n s tma i lemi otomatik olarak ba lar ve hedef s cakl na ula lmas durumda kontrol kart ekran nda g rsel ve sesli uyar verir Kabin i ine r n y klemesi yap l p f r n kap s kapat ld nda pi irme i lemine...

Страница 21: ...fabrikasyon olarak 55 C ayarlanm t r H z so utma i leminin etkin olarak ger ekle tirilmesi i in f r n kap s n a k konumda olmas gerekmektedir FAN HIZ AYARI 8 Fan devri 1 ile 6 aras nda farkl h zda ay...

Страница 22: ...ekilde kapat n z Temizlik sonras nda mutlaka baca borular n tekrar a k hale getiriniz At k gaz zehirlenmesi Patlama Tehlikesi TEM ZLEME Hava giri filtresinin bak m Cihaz pano alt taraf nda bulunan ha...

Страница 23: ...igorta at k Elektronik kontrol nitesinin a r ak m koruma eleman de i meli L tfen yetkili servis birimiyle ileti ime ge iniz E110 zole 24Vdc Besleme Hatas Elektronik kart d k voltaj enerji giri problem...

Страница 24: ...Br l r fleme motorunu kontrol ediniz RESET butonuna basarak hatan n kayboldu unu g zlemleyiniz Hatan n devam etmesi durumda l tfen yetkili servis birimiyle ileti ime ge iniz E402 Kabin alt gaz yak c...

Страница 25: ...that it is fitted to its place exactly Electric water and gas connections of the oven must be realized as per the instructions of the installation Danger Warning Caution Dangerous situations those may...

Страница 26: ...ng for shorter periods Fire danger Remove the packing materials grids and the accessories inside the oven kabcabinet 3 SAFETY INFORMATION Keep this manual in a place where all of the users will always...

Страница 27: ...e professional kitchens Any other intention of use is against the purpose of real usage and thus can be dangerous Food containing flammable material such as food containing alcohol should not be cooke...

Страница 28: ...because of the exiting of the hot air steam through the door Burning danger Please touch the accessories in the hot cooking chamber oven cabinet and other stuff only with heat resistance clothing Burn...

Страница 29: ...electricidad V 230V 1N AC 50Hz Max Elektriksel G c Max Electrical Power Max Electrical Power Max Potencia el ctrica kW 2 4 1 1 1 1 Max Gaz G c Max Gas Power Max Potencia de gas kW 50 25 15 S cak Hava...

Страница 30: ...m 3 h BOY LENGTH mms EN WIDTH mms HEIGHT mms SIDE SIZE OF CHIMNEY mms SINGLE SUCTION HOOD EXHAUST FLOW DOUBLE SUCTION HOOD EXHAUST FLOW 40 TEPS L 40 TRAYS 1500 1470 500 750 4115 1 2895 8 20 TEPS L 20...

Страница 31: ...31 6 FUNCTION COMPONENTS Parts of the oven 1 VOLUME UTILE 2 CONTROL PANEL 3 DOOR HANDLE 4 ELECTRONIC CARD 5 OVEN TROLLEY 6 OVEN LIGHTING 7 OVEN CHIMNEY OUTLET...

Страница 32: ...n positioning the equipment ensure that the oven door can be opened at least 110 for an easy loading and unloading 8 WATER CONNECTION The plumbing to the water inlet should be 3 4 and connect a ball v...

Страница 33: ...hoses should be realized according to the standard of TS EN 14800 Check whether the equipment is suitable for the gas type connected If not then please see chapter Conversion to Different Gases After...

Страница 34: ...uipment type and combustion chamber and also the amount adjustment of gas flow and the emission of chimney gas checks on gas valve suitable to the emission values of chimney gas must be realized The p...

Страница 35: ...minutes GN 2 1 40 60mms trays used for food suitable to bake in the oven contain for example 40 chicken drumsticks with sauce and the baking period is between 75 80 minutes In this case if the oven op...

Страница 36: ...ng and crusting of the product must be prevented When loading the trays on the rack trolley pay attention that they are in alignment and the trays are placed full lenght of the tray slides Otherwise t...

Страница 37: ...37 15 GENERAL VIEW...

Страница 38: ...ng procedure starts automatically and in case the target heat is reached there is an audiovisual warning on the display of the control card When the oven is loaded with the product and the oven door i...

Страница 39: ...ous cooking cycle The temperature of the oven cabinet is adjusted at 55 C as factory setting In order to realize the rapid cooling effectively the oven door should be left open FAN SPEED ADJUSTMENT 8...

Страница 40: ...enter them After the cleaning the pipes of the chimney should definitely be opened again Waste gas poisoning Explosion Danger 22 CLEANING The maintenance of air inlet filter The equipment self detect...

Страница 41: ...work is faulty and there is power failure of the network E109 Fuse blown The element of the overcurrent protection of electronic control unit must be canged Please get in touch with the authorized ser...

Страница 42: ...he gas connection of the equipment Check the burner blowing motor Observe that the error disappears by pressing button RESET If the error continues please contact the authorized service E402 The contr...

Страница 43: ...R UP BURNER DOWN BURNER TC1 TC2 MEAT PROBE TC3 TC4 TC5 TC TB THERMOCOUPLES 0V SW ROTARY ENCODER SW B A 5V TC TB TC TC TQ TQ COOLER COOLER AUX AUX OUTPUTS DS TH PB La 5 Na L N 0V 24Vdc Ra 6 7 8 1 2 3 L...

Страница 44: ...Ate leme Bujisi Kabin st Yak c Igniton Electrode Cabin Up Burner INV1 Motor H z Kontrol Invert r Motor Speed Control Inverter K1 Kontakt r Contactor L1 Kabin Lambas Cabin Lamp L2 Kabin Lambas Cabin L...

Страница 45: ...SW ROTARY ENCODER SW B A 5V TC TB TC TC TQ TQ COOLER COOLER AUX AUX OUTPUTS DS TH PB La 5 Na L N 0V 24Vdc Ra 6 7 8 1 2 3 LINE IN OUT 2 OUT 1 FKG40 M2TP 0 75 mm NYAF 3x1 50 mm NYAF 0 75 mm NYAF K1 CAB...

Страница 46: ...si Kabin st Yak c Igniton Electrode Cabin Up Burner INV1 Motor H z Kontrol Invert r Motor Speed Control Inverter K1 Kontakt r Contactor L1 Kabin Lambas Cabin Lamp L2 Kabin Lambas Cabin Lamp L3 Kabin L...

Отзывы: