33
If a frequency inverter (speed control) is used in the equipment, (from inlet terminal)
an AC/DC precision TYPE B RCD (residual current device) must be used before
the power inlet of the equipment .”
- The equipment should be used with a power supply cable type H07RN-F at least .
- Connect the energy supply cable considering the circuit diagram of the equipment.
10.GAS CONNECTION
The gas connection of the equipment should be realized by an authorized service
personnel.
In case of emergency, a gas valve should be fixed to an easy to reach point in order
to disconnect the gas supply quickly.
All of the parts necessary for the installation will be supplied by manufacturer.
The connections of the flexible gas pipe or gas hoses should be realized according
to the standard of TS EN 14800.
Check whether the equipment is suitable for the gas type connected. If not, then
please see chapter "Conversion to Different Gases".
After all the connections were realized, perform the gas leakage control on the
connection points .
11.CONVERSION TO THE DIFFERENT GASES
The equipment is adjusted to operate at 20mbar NG(G20) gas. If it is requested to
operate with another gas, an authorized service should be contacted .
If the equipment is converted to another gas other than the factory setting, stick an
adhesive label on a visible surface of the equipment.
Gas leakage control should be realized and ensure that the system of chimney is
properly operating.
THERMAL POWER CONTROL
After the installation has been realized, conversion to the different gases or any
maintenance procedures, the thermal power of the equipment should be checked .