background image

ERROR

POSSIBLE CASUSES

POSSIBLE REMEDIES

Equipment 

is 

not

powered .

It is not plugged .

Plug in/ call the authorized service.

Power inlet cable is out of order/ cut Check / call the authorized service..
Main  switch  of  the  equipment  is
turned off.

Turn  on  the  mains  switch  /  call  the
authorized service.

Control board is not  energized.

Check / call the authorized service..

On/off button is turned off.

Turn on the on/off button  .

Equipment 

does 

not

cool enough .

Cooling  temperature  is  not  selected
correctly.

Check  the  cooling  temperature  and,  if
necessary, increase the temperature.

Equipment is positioned near a heat
source    (cooker,  oven  etc.)  or  being
exposed to directly .

As defined in “INSTALLATION” chapter,
keep  away  the  equipment  from  the  source
of heat and direct sunlight.  .

Ventilation holes are obstructed.

Open the ventilation holes.

Condenser is dirty.

Check / clean.

In  the  cooling  cycle,  there  is  a
discjucture/cut  at  any  point  or  the
cooling gas finished.

Call the authorized service..

Evaporator has excess frost deposit.

Perform a defrost cycle.

Ambient  temperature is too high.

Check  the  ambient  temperature  and,  if
possible,  reduce.

Equipment  cools  too
much .

Cooling  temperature  is  not  selected
correctly.

Check  the  cooling  temperature  and,  if
necessary, decrease the temperature.

Equipment 

does 

not

illuminate .

It is not plugged.

Plug in. / call the authorized service.

Power  cable is out of order/ cut .

Check / call the authorized service..

Mains switch is turned off.

Turn on the mains switch.

Control board is not energized.

Check / call the authorized service..

Illumination button is turned off.  .

Turn on the illumination button  .

Flourescant lamp is out of order.

Check / call the authorized service..

Refrigerator  motor  does
not operate.

Socket is not energized.

Check.

Cooling  control  device  is    turned
off.

Check / turn on.

Condenser fan does not work.

Call the authorized service..

Other

Call the authorized service.

Refrigerator 

motor

operates noisy.

Condenser is dirty.

Check / clean.

Fan motor is out of order .

Call the authorized service..

Other

Call the authorized service.

Equipment 

does 

not

defrost .

Defrost  adjustment  is  not  done  on
the cooling control device.

Check. Adjust defrost.

Cooling  control  device  is  out  of
order.

Call the authorized service..

Other

Call the authorized service..

STORAGE TEMPERATURES AND   PERIODS OF SOME FOODS

FOOD

TEMPERATURE

(

0

C )

PERIOD

Meat

0 ÷ 2

3-5 days

Minced meat

0 ÷ 2

1-2 days

Fish

-1 ÷ 0

1-2 days

Egg

4 ÷ 7

1 week

Pasteurized milk

3 ÷ 4

1 day

Soft fruit

4 ÷ 7

2 days

Hard fruit

4 ÷ 7

2 week

Green vegetables

4 ÷ 7

5 days

Other vegetables

4 ÷ 7

2 week

Содержание INO-SDF070/S

Страница 1: ...RATEUR DEPO T P BUZDOLABI CABINETS TYPE REFRIGERATOR REFRIGERATEUR DE TYPE CABINETS INO SDN S 070 140 DEPO T P DER N DONDURUCU CABINETS TYPE DEEP FREEZER INO SDF S 070 140 MALAT I F RMA NOKSAN MUTFAK...

Страница 2: ...2 DEPO T P BUZDOLABI CABINETS TYPE REFRIGERATOR REFRIGERATEUR DE TYPE CABINETS...

Страница 3: ...3 INO SDN140 S DEPO T P BUZDOLABI DEPO T P BUZDOLABI CABINETS TYPE REFRIGERATOR REFRIGERATEUR DE TYPE CABINETS...

Страница 4: ...ital termometre ve termostat otomatik defrostlu Fanl so utma D G vde Saclar Paslanmaz elik evre dostu ve 45 kg m 134A evre Dostu CFC Free Poli retan zolasyon Y ksekli i ayarlanabilir paslanmaz elik ra...

Страница 5: ...ta nmal d r r nler ta nacak yer ve uzakl a g re m teri iste ine ba l olarak paketli yada paketsiz gidebilir Paketler mukavva strech film yada buna ilave olarak ah ap kafesli olabilir Y kleme ve ta ma...

Страница 6: ...n z 6 5 Cihaz n kapat lmas A ma kapama d mesini Off konuma getiriniz Elektrik fi ini prizden ekiniz 7 TEM ZL K ve BAKIM Cihazda temizlik yada bak m faaliyetine ba lamadan nce mutlaka cihaz fi ini pri...

Страница 7: ...ir yerde kopma kesilme olmu tur yada so utma gaz bitmi tir Yetkili servis a r n z Evaparat r a r karlanm t r Evaparat r n karlar n n eritiniz defrost Cihaz n bulundu u ortam s cakl a r fazlad r Ortam...

Страница 8: ...lders Removable and easy cleaning magnetic gaskets Special door and hinges design Special and ergonomic design Adjustable feet Cooling gas R 404 A R 134 A Ambient temperature 35 C 2 8 SDN 140 070 Ambi...

Страница 9: ...leads to further problems To ensure a long life of the device strictly effect defrosting whenever any frost occurs Avoid cleaning the device with direct or high pressure water jet otherwise your elect...

Страница 10: ...n the ventilation holes Condenser is dirty Check clean In the cooling cycle there is a discjucture cut at any point or the cooling gas finished Call the authorized service Evaporator has excess frost...

Страница 11: ...d Sur le menu de programmation vous acc dez au niveau affich sur l cran ou acceptez la nouvelle valeur pendant le r glage d un param tre Cl SORTIE Lorsque vous appuyez et maintenez pendant 5 secondes...

Страница 12: ...des choses L utilisation de ces dispositifs dans les environnements o il y a des risques d explosif et d incendie dans des mauvaises conditions m t orologiques o il n y a pas de l air propre o il y a...

Страница 13: ...re 1 heure avant de mettre votre appareil en marche De cette fa on l huile qui a t m lang e dans le syst me pendant le transport ou la manutention retournera au compresseur Votre appareil a t con u po...

Страница 14: ...a factur s par ment Si l appareil n est pas faire marcher pour longtemps d brancher enlever les aliments et nettoyer toute la surface avec un d sinfectant contre l oxydation qui n endommage pas les al...

Страница 15: ...t teint V rifier allumer Le ventilateur du condenseur ne fonctionne pas Appeler le service autoris Autre Appeler le service autoris Le moteur du r frig rateur fonctionne bruyamment Le condenseur est s...

Страница 16: ...liance at a sufficient distance away from heat sources such as stove furnace radiators and sunlight 3 ELECTRICAL CONNECTIONS The appliance should be supplied with the 1N 220V AC 50Hz mains voltage The...

Страница 17: ...of any malfunction arising out of your failure to satisfy the maintenance work under your liability will be charged separately 8 TROUBLESHOOTING The appliance fails to refrigerate Check the thermosta...

Страница 18: ...is not selected correctly Check the cooling temperature and if necessary decrease the temperature Equipment does not illuminate It is not plugged Plug in call the authorized service Power cable is out...

Страница 19: ...85 2100x700x770 2140x750x820 140 INO SDN140 S 2 8 1200 0 95 2100x1400x770 2140x1450x820 175 INO SDF070 S 10 20 600 1 17 2100x700x770 2140x750x820 140 INO SDF140 S 10 20 1200 1 65 2100x1400x770 2140x1...

Страница 20: ...GE 28 21 R134a R404A 22 23 Henkel Helios 50 24 220 230 50 60 10...

Страница 21: ...GE 28 25 6 1 1 350 C 60 430 C 60 6 2 6 3 6 4 6 5 Off 26 15...

Страница 22: ...GE 28 8 15 27...

Страница 23: ...GE 28 28...

Страница 24: ...GE 28 0 C 0 2 3 5 0 2 1 2 1 0 1 2 4 7 1 3 4 1 4 7 2 4 7 2 4 7 5 4 7 2 18 22 10...

Страница 25: ...lateur de Condensateur Condense M3 Ventilateur d Evaporateur Evaporator F RD Defrost resistance R sistance au d givr Tl Capteur d vaporateur Evaporator Sens T2 Capteur de Cabine Cabinet Sensor D Carte...

Страница 26: ...r Condenser Fan M3 Ventilateur d Evaporateur Evaporator Fan RD Defrost resistance R sistance au d givrage Tl Capteur d vaporateur Evaporator Sensor T2 Capteur de Cabine Cabinet Sensor D Carte de contr...

Страница 27: ...eur Condenser Fan M3 Ventilateur d Evaporateur Evaporator Fan RD Defrost resistance R sistance au d givrage Tl Capteur d vaporateur Evaporator Sensor T2 Capteur de Cabine Cabinet Sensor D Carte de con...

Страница 28: ...Condensateur Condenser Fan M3 Ventilateur d Evaporateur Evaporator Fan RD Defrost resistance R sistance au d givrage Tl Capteur d vaporateur Evaporator Sensor T2 Capteur de Cabine Cabinet Sensor D Car...

Отзывы: