9
SMC
7.2 SHOCK FUNCTION
The shock function allows you to apply a shock treatment (chlorinator at 100%) for a
selectable period of time with automatic return to the previous production rate once the
shock period has ended. This feature is useful if the chlorine level has fallen suddenly
for some reason and you want to recover it quickly.
To activate the shock, go to the production screen and press
Λ
SHOCK
for a few
seconds. The following screen will appear:
Select a number of hours, by using the
Λ
or
V
arrows
and press
OK
to accept or
MENU
to exit. If you click
OK
, you will enter the Shock function and the
following screen will be displayed:
If you want to quit the Shock function press any key.
The following screen will be displayed:
Press
OK
to exit the shock function or
MENU
to
continue the shock treatment.
8 MENUS
8.1 Language menu
From the main screen press MENU. Press
V
until the following screen will appear:
Press OK to enter the Language menu.
Choose a language using the arrows
Λ
V
and confirm
by pressing
OK
. Press
MENU
to return back to the
production screen. You can also exit without saving the
setting by pressing
MENU
.
8.2 Polarity Menu
The polarity applied to the cell is periodically reversed to remove calcium build
-
up. The
factory pre
-
programmed period is 8 hours and this is recommended. Depending on the
conditions of your pool it may be necessary to reduce this period in order to increase
the frequency of cleaning.
Note that the longer this period is, the longer the cell
duration will be
. A period of less than 4 hours will drastically reduce the life of the cell.
Inversely, you can increase this period if your cell doesn
’
t need to be cleaned that
Shock 7 h
Select duration
SHOCK 7 h
Remaining: 07:00
Exit Shock?
YES:OK NO:MENU