SMC
26
SALT TOO
LOW
This screen is displayed when the probe detects no water and the control
system stops the production. Verify that there is water in the cell and that its
level reaches the top where the probe is located. A low water level can result
from operating the chlorinator with the pump not turning. In this case switch
the chlorinator off immediately.
THE CHLORINATOR SHOULD NEVER BE POWERED IF THE PUMP IS NOT
WORKING OR IF THE WATER IS NOT FLOWING SUFFICIENTLY. THE
CHLORINATOR POWER SUPPLY SHOULD DEPEND ON THE PUMP POWER
SUPPLY
.
A low water level in the cell may also be due to a dirty filter, an obstructed
circuit or to a pump not powerful enough. As soon as the water level is restored
the fault disappears.
This screen appears when the salt concentration in the water is too low to
prevent cell damage. Add enough salt (5 to 6 kg/m³) and wait until the salt is
completely dissolved. Then press OK to restart the chlorinator. This screen can
also be displayed if the water temperature is too low, if there is a bad electrical
connection between the control unit and the cell or if there is calcium built up
on the electrodes.
This screen appears when the control unit does not detect a celle connected to
it. Make sure the cell is well connected and press OK to restart.
CELL NOT
DETECTED