NV9 Spectral Quick Start Guide
<< Back to Contents
Copyright © Innovative Technology Ltd 201
8
Doc:PA02093
Version: 1
Page 9 of 26
2.5.1
Configuration button functionality
2.5.1.1
Bezel flash counts
The NV9 Spectral Validator leaves the factory preset to at least one currency and
one interface so that it is ready for immediate installation. The dataset and interface
used are shown on the label fixed to the top of the validator head.
2.6
Fault codes
Number of LONG
flashes
Number of SHORT flashes
1
2
3
4
5
1
Note Path Open
Note Path Jam
Unit Not
Initialized
Sensor
Covered
2
Cash Box
Removed
Cash Box Jam
3
Firmware
Checksum
Interface
Checksum
EEPROM
Checksum
Dataset
Checksum
Note Float
Incompatible
4
PSU too Low
PSU too High
Action
Power status
Function
Press and hold (more than 2 seconds)
until the bezel illuminates, then release
Powered ON
Sets validator
Press twice (within half a second)
Powered ON
Shows current interface
type (see flash count
table below)
Press and hold as validator is powered
up
Powered OFF /
ON
Resets to factory
settings
Flash Count
Interface
1
SSP
3
MDB
6
ccTalk
7
SIO
8
Parallel
Information
ccTalk and SSP are
currently implemented
Содержание NV9 Spectral
Страница 1: ...Doc PA02093 Version 1...