background image

Instructions on the Firmware Upgrade for Bank Note Validators 

NC 320, NC 330 and NC 340 

It may be necessary to update the firmware and adjust the settings of the NC 320, NC 330 and NC 340 bank 

note validators if parameters for detecting forged bank notes must be adapted. Introduction of new Euro 

bank notes may also make it necessary. 

 

First of all, please check whether a firmware update is necessary. The firmware versions currently valid are 

listed below (they appear briefly in the display when the machine is switched on): 

 

NC 320:    Display: 320 u4_2

    (Firmware validates the 50 Euro bank note, December 2016) 

NC 330:    Display: 330 u4_0

    (Firmware validates the 50 Euro bank note, December 2016) 

NC 340:    Display: 340 u4_0

    (Firmware validates the 50 Euro bank note, December 2016) 

 

If an older version appears in the display, an update is necessary. 

 

To complete the update, you need:   

a)  The 

programme to transfer

 the firmware to the processor in the bank note validator.   

b)  The firmware as a 

programme code

 (cannot be read as text). 

The  programme  for  data  transfer  and  the  programme  code  of  the  machine  are  provided  on  the 

Olympia homepage. 

c)  A 

serial data transfer cable

 (assuming your computer is equipped with a RS232 serial port). Since 

most modern laptops are no longer equipped with serial ports, a USB-to-serial adapter cable must 

be used. This cable can be obtained from a computer shop or from Olympia. Please note that this 

cable contains electronics which make it necessary to install the corresponding driver regardless of 

the operating system used.   

 

 

 

Olympia article number: 

947730998

 

 

 

 

 

 

 

d)  A serial 

null modem cable

. This is equipped with Sub-Min-D connectors and the poles 2 and 3 are 

crossed. This cable can also be obtained from a computer shop or from Olympia.   

 

 

 

 

Olympia article number: 

947730999

 

 

 

 

Содержание NC 320

Страница 1: ...pears in the display an update is necessary To complete the update you need a The programme to transfer the firmware to the processor in the bank note validator b The firmware as a programme code cannot be read as text The programme for data transfer and the programme code of the machine are provided on the Olympia homepage c A serial data transfer cable assuming your computer is equipped with a R...

Страница 2: ...nd mouse button on this entry and open the properties It should indicate that the device is ready to operate Downloading the necessary files from the Olympia homepage The Olympia homepage www olympia vertrieb de contains the required files in the Firmware Update path under the bank note validators NC 320 NC 330 and NC 340 You must then download these files on your PC in a new path You can then fin...

Страница 3: ...ly select the processor of the bank note validator Processor STC90C58AD should be set in the MCU Type window at the top left If this is not the case open the path STC90C58AD Series in this field Then select the processor type STC90C58AD from this path ...

Страница 4: ...set up Select the programme code relevant for your machine NC3x0_3_1 hex and confirm it Step 3 Configuring the serial port COM port Max Baud Min Baud Define the settings for the serial port a Select the COM Port it may have been displayed during installation of the USB to serial adapter otherwise is must found by trial and error b Set the max baud rate to 9600 c Set the min baud rate to 2400 Step ...

Страница 5: ... an error message appears change the COM Port number in Step 3 Then press the Download Program button again The following appears in the display Checking target MCU The bank note validator is then switched on It is correct when the bank note validator does not display anything during data transfer A progress bar appears on the screen which indicates the transfer status ...

Страница 6: ...When data transfer is finished Complete appears in the display ...

Страница 7: ... bank note validator can be switched off and the connection with the USB to serial adapter disconnected A 100 Euro bank note should be used for the final alignment Please insert this bank note in all four directions The bank note validator is now ready to use with the updated firmware installed ...

Отзывы: