Innovate Motorsports MTX-D Скачать руководство пользователя страница 1

11-0130A 

 
 
 
 

 

 

 

MTX-D, Boost/Shift Gauge 

User Manual

 

 

 

 

1

 

Mounting and Sensor Installation ............................................................. 2

 

1.1

 

Mounting the Gauge ........................................................................ 2

 

1.2

 

Changing the MTX gauge face and/or bezel ................................... 2

 

1.3

 

MAP sensor ..................................................................................... 2

 

2

 

Wiring ....................................................................................................... 3

 

2.1

 

Main Gauge Wiring .......................................................................... 3

 

2.2

 

MAP sensor wiring .......................................................................... 4

 

2.3

 

Tach signal wiring ............................................................................ 4

 

3

 

Download the Logworks 3 software package .......................................... 4

 

3.1

 

Installing software ............................................................................ 4

 

3.2

 

Connecting to LM Programmer ....................................................... 5

 

3.2.1

 

Programming the Gauge ............................................................. 5

 

3.2.2

 

Pressure ...................................................................................... 6

 

3.2.3

 

RPM ............................................................................................. 7

 

3.2.4

 

Display ......................................................................................... 8

 

3.2.5

 

Updating the Firmware ................................................................ 9

 

3.3

 

LogWorks ...................................................................................... 10

 

3.4

 

Logging data .................................................................................. 10

 

3.4.1

 

Adding and Logging MTS channels .......................................... 11

 

Appendix A:  Limited Warranty ...................................................................... 12

 

 

 

 

Содержание MTX-D

Страница 1: ... Main Gauge Wiring 3 2 2 MAP sensor wiring 4 2 3 Tach signal wiring 4 3 Download the Logworks 3 software package 4 3 1 Installing software 4 3 2 Connecting to LM Programmer 5 3 2 1 Programming the Gauge 5 3 2 2 Pressure 6 3 2 3 RPM 7 3 2 4 Display 8 3 2 5 Updating the Firmware 9 3 3 LogWorks 10 3 4 Logging data 10 3 4 1 Adding and Logging MTS channels 11 Appendix A Limited Warranty 12 ...

Страница 2: ... from a pressurized source When replacing the bezel and or gauge face verify that the o ring is properly seated Make sure mounting location does not impair visibility or interfere with driving 1 2 Changing the MTX gauge face and or bezel 1 Lay the MTX gauge face down and remove the three 2 phillips screws from the outside rim of the back plate 2 Carefully lift off the bezel from the gauge cup 3 Co...

Страница 3: ...cle s stereo ignition system and fuel pump are not recommended 2 Connect the main BLACK wire to a ground source Note that there are other black wires coming out of the 2 pin and 3 pin connectors these are not the main gauge grounds Avoid noisy ground sources such as grounds used for the radio and or ignition 3 Connect the WHITE wire to a headlight power wire a wire that supplies current when the h...

Страница 4: ...park setup i e MSD 6AL must use the provided tach signal from the ignition box A tach signal can not be acquired from the negative lead of the coil on vehicles with CDI ignitions For these applications use the negative lead of an injector or a tach adapter if available for your model ignition 2 Connect the sensor s male two pin connector to the female two pin connector on the gauge 3 Coming out of...

Страница 5: ...erial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the MTX D 2 Power up the MTX D 3 Launch LM Programmer The LM Programmer application can be launched from Start Programs LogWorks3 LM Programmer from the Windows task bar Avoid connecting or disconnecting ...

Страница 6: ...n requires firmware version 1 02 and newer and LM Programmer 4 04 and newer The MTX U comes programmed from the factory with an atmospheric pressure setting for sea level As altitude rises atmospheric pressure will drop which will effect the gauge s reading 1 To program altitude compensation the MAP sensor must be connected to the gauge and the vacuum pressure line should be disconnected from the ...

Страница 7: ...ected click Yes 5 Finally click the Program button for the setting to take effect 3 2 3 RPM 1 Mode Select how many pulses per rotation based on your tach signal source 2 Scale Select the RPM scale Options are 10230 RPM or 20460 RPM Selected 20460 RPM if your engine rev passed 10230 RPM ...

Страница 8: ...s outer LEDs to flash incrementally Boost Trace is disabled when the Progressive shift light is enabled 2 Single Stage Shift Light Allows the configuration of either Green Yellow Red or All LED segments to flash at the desired shift threshold This selection is enabled when Single Stage is selected in Needle Bar RPM Config 3 Progressive Shift Light Allows the configuration of the progressive shift ...

Страница 9: ... adapter then connect the adapter to the computer 6 Launch LM Programmer The LM Programmer application can be launched from Start Programs LogWorks3 LM Programmer from the Windows task bar 7 Once connected the LM Programmer will display the current version of the firmware that is installed in the LM 2 Do not update the firmware if the versions are the same A firmware update should only be necessar...

Страница 10: ...re should be nothing connected to the port labeled IN 4 Power ON the MTX Boost Shift gauge 5 Connect the serial cable to your computer If you are using a serial to USB adapter connect the serial cable to the adapter then connect the adapter to the computer 6 Launch LogWorks The LogWorks application can be launched from Start Programs LogWorks3 Logworks3 from the Windows task bar 7 Once LogWorks la...

Страница 11: ...to 4 Pin Molex 4ft p n 3846 2 5mm to 2 5mm Stereo 4ft p n 3760 2 5mm to 2 5mm Stereo 6in p n 3789 4 Pin Molex to 2 5mm Stereo 4ft p n 3812 To daisy chain MTS devices together 1 Power OFF all your MTS devices 2 Start with the first product in the serial chain Using the appropriate mating cable connect the OUT port from the first device and feed it into the IN port of the second device Note If you h...

Страница 12: ... and shipped charges pre paid along with proof of purchase and the return material authorization form to the Innovate repair location as instructed by Customer Service Innovate within a reasonable amount of time from its receipt of your product so shipped will ship to you at its option the repaired product or a new or reconditioned product of comparable or greater specified functionality All repai...

Отзывы: