8
10
2 x USB Female A connectors for connection with Innovasub Pressure sensor.
Connectors NOT USB COMPLIANT. Do not connect any USB device to these
connectors.
1 x Micro-SD socket. Connected to the SPI port of the MSP430.
11
Underwater Wireless Module, connected to the UART1 port (USCI0) of the
MSP430.
12
2 x High precision, 10-turn potentiometer. Connected to 12-bit ADC of the
MSP430.
2 x Piezo-electric switches. Connected to digital, interruptible input of the
MSP430.
13
4 x General purpose LEDs. Connected to digital output of the MSP430.
14
Port for connection with Oxygen Sensor. Jack 3.5mm or standard 0.1”
connectors available. DO NOT USE BOTH CONNECTORS AT THE SAME
TIME as they are connected to the same 12-bit ADC input.
15
General purpose 12-bit ADC acquisition. Connection for custom board.
6 x ADC inputs, power from battery and regulated 3.3V, Digital and Analog
grounds.
16
MS5541C pressure sensor mounted on INNOVASUB PCB.