6.4 Cooling mode function requirement
6.4.1. The compressor will be activated by sensing the difference between setting temperature and the
actual ambient room temperature.
6.4.2. The compressor operates as below:
(TA-Ts)
℉
+2
0
Operation conditon
compressor off with a delay of 1 minute
compressor on
When TA
≤
TS, compressor off
When T1>TS+2
F, compressor on
6.4.3. The ION/TIMER/SLEEP/ENERGY SAVE/FOLLOW ME functions are valid at the cooling mode.
6.4.4. Auto-defrosting function protection as below:
When TE is lower, it means that the evaporator frosts. Then the unit starts defrosting, and the
indoor fan keeps working at the moment. When the temperature is up, the unit stops defrosting.
TE
℉
55
30
compressor off
when TE is lower than 30
℉
lasting for 5 seconds
compressor on
Содержание RE05C1D1
Страница 1: ...SERVICE MANUAL RE05C1D1 RE05C1M1 RE06C1D1 RE06C1M1 RE08C1D1 RE08C1M1 RE10C1M1 RE12C1D1 RE12C1M1 ...
Страница 12: ...10 5 Wiring Diagram 1 RE05C1M1 RE06C1M1 202021191021 ...
Страница 13: ...11 2 RE12C1D1 RE05C1D1 RE06C1D1 RE08C1D1 202021190003 ...
Страница 23: ...21 8 Operation characteristics 8 1 Cooling operation For mechanical model For remote control model ...