background image

MU8016-012ENG rev02

10

-4- 

MAINTENANCE, SERVICING, STORAGE

a)  Before each use, the user must read and understand the manufacturer’s Instruction and 

safety manual. Ensure that the markings are visible at all times.

b)  Before each use, carefully inspect the XTIRPA system and all components and parts there-

of. Any defective parts or components could result in serious injury or death.

c) 

The standards require a regular inspection program for all confined space entry / retrieval 

equipment, as well as keeping up-to-date documented results of these inspections. Use 
the maintenance and inspection sheets included in this Instruction and Safety Manual to 
document your results.

d)  It is recommended that the anchoring device be marked with the most recent or next inspec-

tion date.

e)  Remove the XTIRPA system from service if a problem or an unsafe or defective condition 

is found during the inspection. Return to an authorized service center or the manufacturer 
for service.

f)  Replacement components and parts and additional maintenance and servicing procedures 

must be completed by an authorized service center which has been approved by the manu-
facturer, or by the manufacturer itself.

g)  Establish a monthly inspection which should be done by a competent person (person who 

is familiar, has been trained and has read and fully understands this instruction and safety 
manual), other than the user.

h)  Periodically clean the exterior of the davit arm and base, using water and mild detergent. 

Clean labels as required.

WARNING: 

A periodic inspection must take place at least once every twelve months.

i)  When lowering the removable system, it is important to slowly place the system on the 

ground, to avoid damaging components.

j)  Store the XTIRPA system in a clean and dry environment, out of direct sunlight. Avoid areas 

with chemical or toxic vapors, substances or environments. Do not immerse or leave in direct 
contact with water, as corrosion and rust may occur. Inspect the XTIRPA system after any 
period of extended storage and at least once a month.

k)  The XTIRPA system and its components was designed for 10 years of continuous service. 

The life expectancy of the XTIRPA system and its components will be determined after 
periodic and monthly inspections that will determine whether or not the product may remain 
in service.

l)  All components and parts of the XTIRPA system should be stored in separate bags to facil-

itate transport and handling.

Содержание XTIRPA IN-8016

Страница 1: ...RPA DAVIT ARM AND MAST SYSTEM FOR PPE UNIVERSAL RESCUE SYSTEM IN 8016 INNOVA Public Utility Products Inc 1040 Boulevard Industriel Granby Qu bec Canada Tel 450 777 1240 Fax 450 372 9936 www xtirpa com...

Страница 2: ......

Страница 3: ...rements of the EN 795 2012 Type A and TS16415 2013 standard IMPORTANT The buyer must complete and return the limited warranty registration form Always keep this instruction and safety manual available...

Страница 4: ...e occurrence of a fall or the safety of the equipment is in doubt equipment must be immediately removed from service and inspected by qualified personnel before reuse Maximum permissible arresting for...

Страница 5: ...rators circulating near the XTIRPA system of the presence of the XTIRPA system and its workers before starting work f Wear all appropriate certified and recommended security equipment such as but not...

Страница 6: ...modifications or additions to the equipment shall be performed without the authorization of the manufacturer and all repairs shall be done as indicated by the operat ing procedure of the manufacturer...

Страница 7: ...e without the prior written consent of the manufacturer and any repairs must be undertaken in accordance with the manufacturer s procedures WARNING It is established and agreed that the equipment syst...

Страница 8: ...lity of the complete XTIRPA system and may result in serious injury or death for which the manufacturer disclaims all warranties and liabilities whatsoever user owner and purchaser of the XTIRPA syste...

Страница 9: ...if the safety function of one component can be affected by that of another component WARNING It is essential for the safety of the user if the product is resold to a destination outside the first cou...

Страница 10: ...approved by the manu facturer or by the manufacturer itself g Establish a monthly inspection which should be done by a competent person person who is familiar has been trained and has read and fully...

Страница 11: ...als including without limitation damages resulting from abuse lack of maintenance improper handling or storage voluntary damages vandalism accidental damages or damages resulting from impact or collis...

Страница 12: ...e XTIRPA system Alterations or misuse of the XTIRPA system or failure to follow instructions may result in serious injury or death for which the manufacturer disclaims all warranties and liabilities w...

Страница 13: ...6 012ENG rev02 13 Illustration 2 IN 2005 Illustration 3 IN 2013 Illustration 8 IN 8016 Illustration 1 IN 2395 Illustration 4 IN 2105 Illustration 7 A2395 07 Illustration 5 A2395 06 Illustration 6 A239...

Страница 14: ...ollow instructions may result in serious injury or death for which the manufacturer disclaims all warranties and liabilities whatsoever user owner and purchaser of the XTIRPA system waiving all claims...

Страница 15: ...5 A second lifeline can be installed on the gray D anchor point 6 Remove the pin near the small pulley and rotate the semicircular bracket in order to pass the cable between the two pullies Once the c...

Страница 16: ...The anchoring point must be above the user s position WARNING If necessary use a manhole guard to secure your working area and to prevent falls IMPORTANT Make sure the lifeline cable or rope is posit...

Страница 17: ...er disclaims all warranties and liabilities whatsoever user owner and purchaser of the XTIRPA system waiving all claims rights and recourses against the manufacturer derived therefrom Connectors hooks...

Страница 18: ...tion the winch support bracket at the desired height and lock it with the two lock pins attached on the bracket Install the winch on the bracket pass the cable into one of the corner pulleys Put back...

Страница 19: ...CALCULATION DIAGRAM Ground Clearance Pay attention to the distance to the ground Length of the lanyard carabiner Extended length of the absorber Distance between harness buckle and feet 4 9 1 5 m Mini...

Страница 20: ...ORROSION WELDING OTHER SPECIFY INSPECTED BY CORRECTIVE ACTION TAKEN if required PINS HARDWARE STRUCTURAL DAMAGE TM Any failure to follow the Manufacturer s instructions contained in the Instruction an...

Страница 21: ...Manufacturer s instructions contained in the Instruction and safety manual including with regard to the inspection and maintenance of the XTIRPA system and of components and parts there of will cause...

Страница 22: ...MU8016 012ENG rev02 22 NOTES...

Страница 23: ......

Страница 24: ...anufacturing Plant Innova Public Utility Productions Inc 1040 Boulevard Industriel Canada Qc Canada J2J 1A4 Phone 450 777 1240 Toll free 1 800 461 1937 www xtirpa com Xtirpa is a registered trademark...