CREATING THE ANCHOR POINTS ON THE WINDOW FRAME

 

in metal, plastic, and wood windows.

 

 

Checking the anchor substrate thoroughly (stability and anchoring of the window 
frame) is the most important prerequisite.

 

Test loads according to EN HD 1000 = 1.25 kN (125 kg) per anchor point. 

 

ATTENTION: (the system is not suitable for sliding windows.) 

 

 

The coaxial horizontal bores in the window frame should only be drilled by 

competent experts

 

(e. g. specialised metal company).  If necessary, choose a different restraint system (e.g. PPE) for 
drilling the anchor points.

 

Should you have doubts about the stability of the anchor point, you can test the strength of the 
window frame and the anchor point.

 

A suitable 

test device

 

PG 01

 has been developed by the manufacturer INNO

TECH

.

 

 
 

WORK SITE  (determining the elevation of the anchor point)

 

 

Stand on window sill:

  If the window sill is the highest elevation of the work site, install at least 

2 telescopic rods at the anchor points marked in red on the window frame (Fig. 6).

 

Top guardrail always 1,000 mm above the window sill - intermediate guardrail between 
top guardrail and bottom window frame.

 

On tall windows, vertical distance above top guard rail no greater than 470 mm.

 

 

Stand above the window sill (tall windows):

  If the work site can only be reached from the 

ladder, you can use several safety bars to secure the window or door opening.  The maximum 
intermediate distance is 470 mm.  Constructions like these require that all anchor points on the 
window frame be secured with telescopic bars (Fig. 6a).  

 

Fig. 6   

 

 

 

 Fig. 6a 

Содержание FAS 01

Страница 1: ...gestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztonsági berendezés felszerelése és használata csak az után megengedett miután a szerelést végző és a használó személyek a nemzeti nyelvükre lefordított eredeti használati utasítást elolvasták és megértették Pozor SLOVENSKY Montaža in uporaba varnostni...

Страница 2: ...fect the safety of the user when working in high places Prior to installation or work consult the responsible authorities as to whether the restraint system is suitable for the intended application Adhere to the respective accident prevention regulations when installing using the attachment device INNOTECH FAS 01 03 Before starting the work you must ensure that no objects can fall to the ground fr...

Страница 3: ... fall prevention system Do not put tools or working materials on the fall prevention system Do not use the fall prevention system for windows as a child safety harness Do not use the fall prevention system for windows for hoisting or letting down scaffolds construction materials and cleaning materials etc INNOTECH FAS 01 03 have been developed for personal safety and may not be used for other purp...

Страница 4: ...ted easily and carried along from window to window Since it can be adjusted to the respective width of the window with only a few steps and thanks to the anchor points prepared in the window frame the telescopic bar safely restrains the user and provides reliable protection BRIEF INSTRUCTIONS attention for exact application follow pages 5 6 ADJUSTMENT LENGTHS AND WEIGHT Fig 1 STANDARDS TEST CRITER...

Страница 5: ...ws with both hands pull locking bolt B and adjust the system to the respective window size using the adapter Correct setting light width of the window frame plus approx 50 mm to 150 mm Fig 3 Attention make sure locking bolt B has snapped back into place after each pre adjustment Proceed by shortening the fall prevention system for windows by pulling locking A pushing the perforated silver extensio...

Страница 6: ...and B must be locked securely in place Fig 5 MAINTENANCE All moving parts must be treated with acid free lubricant at least once a year and as needed Check the fall prevention system for windows for obvious defects prior to every use STORAGE Always store the fall prevention system for windows in a dry location and with the spring slackened ATTENTION The FAS 01 03 fall prevention system for windows...

Страница 7: ...trength of the window frame and the anchor point A suitable test device PG 01 has been developed by the manufacturer INNOTECH WORK SITE determining the elevation of the anchor point Stand on window sill If the window sill is the highest elevation of the work site install at least 2 telescopic rods at the anchor points marked in red on the window frame Fig 6 Top guardrail always 1 000 mm above the ...

Страница 8: ... anchor points is necessary for the proper functioning of the fall prevention system for windows We recommend that you use drilling jigs to ensure the greatest possible precision Fig 7 Fig 7a Select the most suitable and safest points on the window frame to act as anchor points in the frame seal of the window profile Fig 7 Fit only certified INNOTECH guide bushes into all anchor points Fig 7 ATTEN...

Страница 9: ... as well as frame and centre spar profiles with hollow cavities or a full cross section Special guide bushes are available from your FAS 01 03 dealer Fig 8 Type FHS GUIDE BUSH TYPE FHB The bushes are installed into the window frame using clips and two screws These bushes are used for instance instead of FHS bushes when the use of FHS bushes is not deemed reasonable or as repair bushes if a bore ha...

Отзывы: