INSTALLATION UNDER
COOKER HOOD
Allow the Heat Sensor to reach room temperature before use. The power
to the cooker must be switched off (at the consumer unit). See the table
below for the mounting location and follow instructions 1–4.
Starting the Heat Sensor
Insert the battery and place the
Heat Sensor on the installation
plate.
Press the button shortly.
(LED flashes green).
Check installation height
If the distance from cooker to Heat Sensor is more than 60 cm, the Heat
Sensor's sensitivity level must be adjusted manually.
Please refer to the table underneath together with the information on
page 18, alternatively watch the film on sensitivity configuration.
3
DISTANCE FROM COOKER
TO HEAT SENSOR
MOUNTING LOCATION
SENSITIVITY LEVEL CONFIGURATION
0–60 cm
wide cooker
61–90 cm
wide cooker
Sensitivity
Acknowledgement "beep(s)"
81–100 cm
Zone 1 & Zone 2
Zone 1
3 presses
76–80 cm
Zone 1
Zone 2
*
Zone 1
*
4 presses
71–75 cm
5 presses
65–70 cm
6 presses
61–64 cm
7 presses
45–60 cm
Factory setting
8 presses
* The installation may not in all cases meet all EN standard requirements.
See FAQ, page 20, point 4
Please note: the sensitivity level of the Heat Sensor is
confirmed by the appropriate sound pattern sequence
only and not the LED flashes.
Watch the film:
https://vimeo.com/321503955
Setting sensitivity
4
Watch the film:
https://vimeo.com/321502592
Sensor installation
7
Содержание Stove Guard SGK5010