Innohome Stove Guard SGK5010 Скачать руководство пользователя страница 19

Checking the  

sensitivity level

1. Remove the Sensor from the 

installation plate. (The Sensor 

gives 4 “beeps” (         ) and the 

cooker is switched off.)

2. Press and hold the button 

(approx. 10 sec.) until 2 “beeps” 

(     ) are heard.

3. An unadjusted Sensor’s sensi-

tivity setting is level 8, and when 

checking the level, the Sensor 

gives a set of “beeps” as follows: 

8 -  8 - 5 - 8. If the sensitivity was 

adjusted to level 4, the sensor 

would give “beeps”: 4 - 4 - 5 - 4.  

Reset the Heat Sensor 

to factory settings

Remove the Sensor from the 

installation plate. (The Sensor gives 

4 “beeps” (         ) power is cut off 

to the cooker).

1. Remove the battery lid. 

2. Press the button once. 

3. Return the battery lid. The Heat 

Sensor shall make a "beep". 

4. Press and hold the button until 

the three "beeps" are heard. 

Release.

If three "beeps" cannot be heard, 

something went wrong. Repeat 

from Step 1. Return the Heat Sensor 

to its installation plate and press the 

button once.

“BEEP” “BEEP” “BEEP”

1

2

3

4

Watch the film:

https://vimeo.com/321504101

Checking sensitivity

Watch the film:

https://vimeo.com/321504446

Factory settings

“BEEP” “BEEP”

19

Pairing devices

The units are already paired at the factory. 

When replacing the Heat Sensor or the Control Unit, 

the devices must be paired again.

Note!

 The Heat Sensor must be 

placed on the installation plate 

during pairing.

1.  Check that the cooker is 

connected to the power 

supply.

2.  Press and hold the reset 

button firmly for 20 seconds. 

The Control Unit will emit 

two sets of clicks and buzzes 

(approximately after 5 and 

20 seconds). Release the 

reset button after the second 

set of clicks and buzzes. The 

Control Unit is now ready to 

be paired. 

3.  Press and hold the NEW 

Heat Sensor button until 

it emits a “beep” (   ) and a 

red LED flashes. The Control 

Unit makes a buzzing sound 

and the Heat Sensor emits a 

“beep” (   ).

4.  After 5 seconds, the Heat  

Sensor gives an alarm (first 

one "beep" and after a while 

continuous beeping). The 

Control Unit and the Heat 

Sensor are now successfully 

paired.

5.  Reset the test alarm by press-

ing shortly the Heat Sensor 

button. Check that the cooker 

can be turned on. If the Heat 

Sensor does not respond or if 

the test alarm cannot be re-

set, see FAQ, page 22, points 

5 and 6.

Reset 

button

Содержание Stove Guard SGK5010

Страница 1: ...essional kitchen The Control Unit must be installed by an authorised electrician INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION P 4 13 USER GUIDE P 14 21 TECHNICAL SPECIFICATIONS P 22 24 1 2 INN...

Страница 2: ...he Stove Guard will not completely isolate the cooker It must never be used to turn off the cooker s power supply for service repair Do not short circuit charge open or heat the batteries There is a r...

Страница 3: ...arms 16 After alarm Cookers with mechanical controls 16 After alarm Cookers with touch controls 16 Dislocation alarm 16 Action in the event of an alarm 17 Other settings 18 19 Changing the sensitivity...

Страница 4: ...STALLATION 1 Installing the Stove Guard To install correctly follow the instructions STEP 1 Installation of the Heat Sensor p 5 11 STEP 2 Installation of the Control Unit p 12 STEP 3 Function test p 1...

Страница 5: ...iling Follow these instructions for correct installation Installation plate with adhesive tape Heat Sensor Optional IR lens extension black INSTALLATION LOCATIONS 1a Installation under cooker hood 1b...

Страница 6: ...nce Mount the Heat Sensor If there is a metal mesh grease filter on the cooker hood make sure it is greaseless and dry Press at least for a minute from the opposite side while attaching adhesive Caref...

Страница 7: ...nformation on page 18 alternatively watch the film on sensitivity configuration 3 DISTANCE FROM COOKER TO HEAT SENSOR MOUNTING LOCATION SENSITIVITY LEVEL CONFIGURATION 0 60 cm wide cooker 61 90 cm wid...

Страница 8: ...nute while attaching adhesive Carefully remove the protective film from the installation plate Attach the Heat Sensor with the LED facing the user Attach the installation plate while the Heat Sensor i...

Страница 9: ...nsitivity level is 45 60 cm above the cooker Please refer to the table underneath together with the information on page 18 alternatively watch the film on sensitivity configuration DISTANCE FROM COOKE...

Страница 10: ...stance between the cooker and ceiling Place the Heat Sensor directly above the center point of the cooker Make sure that the surface is clean and dry Mount the Heat Sensor Make sure that ceiling is gr...

Страница 11: ...ensitivity configuration DISTANCE FROM COOKER TO HEAT SENSOR SENSITIVITY LEVEL CONFIGURATION Mounting height above the cooker 0 90 cm wide cooker Sensitivity Number of beep s 160 200 cm Recommended Im...

Страница 12: ...cted throughout the entire installation Disconnect the power Switch off the power at the consumer unit Note Do not turn on the Consumer unit before the Heat Sensor is set and ready for a function test...

Страница 13: ...sor will also emit a test alarm after a few seconds Note Check that there is no power going to the cooker Reset the alarm It is important to reset the alarm after a function test to ensure power to th...

Страница 14: ...2 USER GUIDE...

Страница 15: ...at it is not a dangerous situation The Heat Sensor has then learned more about your cooking habits and you can continue cooking Please note When installing the Heat Sensor on the ceiling the learning...

Страница 16: ...all cooker controls to 0 then press the Heat Sensor button once After this the cooker can be used nor mally With ceiling installation reset button is needed to return the power Touch controls If the S...

Страница 17: ...No power The cooker is too hot for the power to be turned back on Make sure that the controls are set to 0 Wait until the cooker has cooled down and the Control Unit starts emit ting a short ring with...

Страница 18: ...correct sensitivity level it is important the process is not rushed Ensure the sensor button is pressed firmly down each time holding for a period of 1 second before releasing Ensure to pause for 1 s...

Страница 19: ...ity Watch the film https vimeo com 321504446 Factory settings BEEP BEEP 19 Pairing devices The units are already paired at the factory When replacing the Heat Sensor or the Control Unit the devices mu...

Страница 20: ...or if it is covered by dirt or grease It can also be triggered by a problem with the radio connection or malfunction of the Control Unit ANSWER 2 Make sure that the Heat Sensor is firmly attached to t...

Страница 21: ...from many retailers or an induction suitable cooking vessel Place the adapter plate on a cooker and perform a heat test by turning on the plate This test is not absolutely necessary as potential prob...

Страница 22: ...Signal LED should face towards use 3 Voltage 230 400 VAC Extremely low energy use approx 1 W Automatic electrical switch For safe connections up to 10 mm2 wires Alarm signal 80 dB A 1 m RF 433 MHz Pat...

Страница 23: ...ur local retailer when purchasing a corresponding new product Proper disposal of this product helps to save valuable resources and prevent potentially harmful effects on human health and on the enviro...

Страница 24: ...ve 2 Stove Guard s maximum supply current allowed is 32A and the appropriate diversity factor is 100 The diversity factor applies to Stove Guard installations with parallel connected relays Type 1 or...