Specifications
15
Working conditions
Operating temperature
-30 °C to +50 °C at full load output
Thermal overload protection: output power reduced at higher temperatures
Air humidity
5% to 95% as defined under IEC 61851-1 Ed.3/EN 61851-1 (2017)
Max. altitude above sea level
Max. 2,000 m (air pressure: 860 hPa to 1,060 hPa)
Protection class
Protection class I
Electrical input/power connection
Input power from eClick
Three-phase current 400 V AC, 32 A (22 kW)/20 A (13.8 kW)/16 A (11 kW)
Alternating current 230 V AC, one-phase, 32 A (7.4 kW)/20 A (4.6 kW)/16 A (3.7 kW)
Charging power
3.7/4.6/7.4/11/13.8/22 kW (16 A, 20 A, 32 A; one or three-phase)
Output power
Three-phase current 400 V AC, 32 A (22 kW) or 16 A (11 kW)
Alternating (one-phase) current 230 V AC, 32 A (7.4 kW) or 16 A (3.7 kW)
Plug assembly
Without charging cable: Type-2 plug assembly as defined under DIN EN 62196-2
with automatic plug locking, shutter
With charging cable: Type-2 plug as defined under DIN EN 62196-2,
plug compartment on eBox, shutter
Consumption measuring
Electricity meter eSmartMeter: optional for eClick, MID-compliant (Europe) and CE-certified
Protective equipment
DC fault current monitoring
(personal protection)
Integrated all-current sensitive current monitor (GFCI) for DC fault monitoring,
response value: DC 6 mA
Welding detection (indication signal for
welded power contacts)
Connection via change-over contact (max. 230 V, 1 A),
use e.g. for shunt release for disconnection of main power path
Integrated overvoltage protection
According to IEC 61851-21-2:2018 (ESD/surge/burst)