Innodisk InnoAGE M.2 (S80) 3TI7 Скачать руководство пользователя страница 21

                                     

   

InnoAGE

TM

 

M.2  (S80)  3TI7

 

21     

   

V1.2                                                                                TPS, July., 2020

 

3.5 Wear-Leveling 

Flash memory can be erased within a limited number of times. This number is called the

 

erase 

cycle limit

 

or

 

write endurance

 

limit

 

and is defined by the flash array vendor. The erase cycle 

limit applies to each individual erase block in the flash device.   

Innodisk InnoAGE M.2 (S80) 3TI7 uses a static wear-leveling algorithm to ensure that consecutive 
writes of a specific sector are  not written physically to the same page/block in the flash. This 
spreads flash media usage evenly across all pages, thereby extending flash lifetime. 

3.6 Bad Blocks Management 

Bad Blocks are blocks that contain one or more invalid bits whose reliability are not guaranteed. 
The Bad Blocks may be presented while the SSD is shipped, or may develop during the life time 
of the SSD. When the Bad Blocks is detected, it will be flagged, and not be used anymore. The 
SSD implement Bad Blocks management, Bad Blocks replacement, Error Correct Code to avoid 
data error occurred. The functions will be enabled automatically to transfer data from Bad Blocks 
to spare blocks, and correct error bit. 
 

3.7 iData Guard 

Innodisk’s iData Guard is a comprehensive data protection mechanism that functions before and 
after  a  sudden  power  outage  to  SSD.  Low-power detection  terminates  data writing  before  an 
abnormal power-off, while table-remapping after power-on deletes corrupt data and maintains 
data integrity. Innodisk’s iData Guard provides effective power cycling management, preventing 
data stored in flash from degrading with use. 
 

3.8 Garbage Collection 

Garbage collection is used to maintain data consistency and perform continual data cleansing on 
SSDs. It  runs  as a background  process, freeing up  valuable  controller resources while  sorting 
good  data  into  available  blocks,  and  deleting  bad  blocks.  It  also  significantly  reduces  write 
operations to the drive, thereby increasing the SSD’s speed and lifespan.   
 

3.9 Trim   

The Trim command is designed to enable the operating system to notify the SSD which pages no 
longer contain valid data due to erases either by the user or operating system itself. During a 
delete operation, the OS will mark the sectors as free for new data and send a Trim command to 
the SSD to mark them as not containing valid data. After that the SSD knows not to preserve the 
contents of the block when writing a page, resulting in less write amplification with fewer writes 
to the flash, higher write speed, and increased drive life. 
 

3.10 iPower Guard 

iPower Guard technology is a set of preventive measures that protect the  SSD  in an  unstable 
power supply environment. This comprehensive package comprises safeguards for startup and 
shutdown to maintain device performance and ensure data integrity. 

Содержание InnoAGE M.2 (S80) 3TI7

Страница 1: ...M 2 S80 3TI7 Customer Customer Part Number Innodisk Part Number Innodisk Model Name Date Innodisk Approver Customer Approver...

Страница 2: ...ty 11 2 4 3 Shock and Vibration 11 2 4 4 Mean Time between Failures MTBF 12 2 5 CE AND FCC COMPATIBILITY 12 2 6 ROHS COMPLIANCE 12 2 7 RELIABILITY 12 2 8 TRANSFER MODE 13 2 9 PIN ASSIGNMENT 13 2 9 1 M...

Страница 3: ...E 24 3 14 WRITE PROTECT 24 3 15 SANITIZING INNOAGE SSD 24 4 1 INNOAGE M 2 S80 3TI7 PIN DIRECTIONS 26 4 2 ELECTRICAL CONNECTIONS FOR INNOAGE M 2 S80 3TI7 26 4 3 DEVICE DRIVE 26 5 SMART FEATURE SET 27 5...

Страница 4: ...M 2 S80 3TI7 4 V1 2 TPS July 2020 REVISION HISTORY Revision Description Date V1 0 First Release Apr 2020 V1 1 Correct part number July 2020 V1 2 Correct the typo of pin header 2 Support Private Cloud...

Страница 5: ...RE RANGE FOR INNOAGE M 2 S80 3TI7 11 TABLE 6 SHOCK VIBRATION TESTING FOR INNOAGE M 2 S80 3TI7 11 TABLE 7 INNOAGE M 2 S80 3TI7 MTBF 12 TABLE 8 INNOAGE M 2 S80 3TI7 TBW 12 TABLE 9 INNODISK INNOAGE M 2 S...

Страница 6: ...TO AZURE CLOUD SYSTEM ARCHITECTURE 19 FIGURE 4 EDGE TO PRIVATE CLOUD SYSTEM ARCHITECTURE 19 FIGURE 5 INNOAGE SSD PARTITIONED FOR FUTURE RECOVERY PURPOSES 24 FIGURE 6 PC RESET PIN CONNECTION TO INNOAG...

Страница 7: ...essages as well as monitor read write behavior patterns to increase the storage device s lifespan Most importantly system operators can quickly revert to the default settings from the cloud based dash...

Страница 8: ...ATA III interface and compliant with SATA I and SATA II SATA III interface can work with Serial Attached SCSI SAS host system which is used in server computer Innodisk InnoAGE M 2 S80 3TI7 is complian...

Страница 9: ...8 213 5 DTM28 B56DK1 1 2 3 QF20G 20 426919088 203 5 DTM28 B56DK1 1 2 3 QF30G 30 405947568 193 5 DTM28 B56DK1 1 2 3 QF40G 40 384976048 183 5 DTM28 B56DK1 1 2 3 QF50G 50 364004528 173 5 512GB DTM28 C12D...

Страница 10: ...e max 30 MB s 60 MB s 125 MB s 255 MB s 315 MB s 4KB Random Read QD32 13500 IOPS 25000 IOPS 48000 IOPS 70000 IOPS 61000 IOPS 4KB Random Write QD32 7700 IOPS 16000 IOPS 32000 IOPS 59000 IOPS 70000 IOPS...

Страница 11: ...512GB InnoAGE M 2 S80 3TI7 2 4 Environmental Specifications 2 4 1 Temperature Ranges Table 5 Temperature range for InnoAGE M 2 S80 3TI7 Temperature Range Operating Standard Grade 0 C to 70 C Industria...

Страница 12: ...M 2 S80 3TI7 MTBF Product Condition MTBF Hours Innodisk InnoAGE M 2 S80 3TI7 Telcordia SR 332 GB 25 C 3 000 000 2 5 CE and FCC Compatibility InnoAGE M 2 S80 3TI7 conforms to CE and FCC requirements 2...

Страница 13: ...SATA pin out See Table 9 for InnoAGE M 2 S80 3TI7 pin assignment Table 9 Innodisk InnoAGE M 2 S80 3TI7 Pin Assignment Signal Name Pin Pin Signal Name 75 GND 3 3V 74 73 GND 3 3V 72 71 GND 3 3V 70 69 GN...

Страница 14: ...In addition InnoAGETM SSD reserves external GPIO pins to connect with system for customized application Pin header 2 is design for connecting with daughter board from SPI to Ethernet See table 10 and...

Страница 15: ...H2 Pin 6 H2 Pin 8 H2 Pin 10 NC NC MOSI CS 3 3V Pin Function Direction Notification 1 INT I Interrupt capable GPIO PWM O PWM control frequency duty TBD GPIO I O Bi direction function programmable 3 MIS...

Страница 16: ...3 3V 9 GND System GND 2 4 NC No internal connection Default setting function VO range 0 28 VOL 0 4 2 4 VOH 3 63 V VI range 0 28 VIL 0 28 2 0 VIH 3 63 V 2 10 Mechanical Dimensions 2 10 1 InnoAGETM M 2...

Страница 17: ...r plugged in during operation User has to avoid hot plugging the SSD which is configured as boot device and installed operation system Surprise hot plug The insertion of a SATA device into a backplane...

Страница 18: ...sk InnoAGE M 2 S80 3TI7 is designed with a SATA III 6 0Gbps Gen 3 controller The Serial ATA physical link and transport layers are compliant with Serial ATA Gen 1 Gen 2 and Gen 3 specification Gen 3 s...

Страница 19: ...e hardware form malicious actors The security provided by the Azure Sphere also encompasses secure and encrypted access to Azure Cloud services Figure 3 Edge to Azure Cloud System Architecture InnoAGE...

Страница 20: ...ice In Private cloud InnoAGE doesn t support Azure sphere OS update and InnoAGE App OTA now 3 4 Error Detection and Correction Innodisk InnoAGE M 2 S80 3TI7 is designed with hardware LDPC ECC engine w...

Страница 21: ...ow power detection terminates data writing before an abnormal power off while table remapping after power on deletes corrupt data and maintains data integrity Innodisk s iData Guard provides effective...

Страница 22: ...rotection encryption needs to be paired with an ATA user password by ATA security command After setting the authorized key by ATA security command every time when you power on the system with SSD encr...

Страница 23: ...T 0XF4 SECURITY FREEZE LOCK 0XF5 SECURITY DISABLE PASSWORD 0XF6 3 12 FW Recovery Function 1 InnoAGE SSD has one drive partition dedicated to recovery meaning that recovery image for the device OS is a...

Страница 24: ...t write to it edit it append data to it or delete it This function can be triggered from cloud to InnoAGE SSD remotely through both in band and out of band channels 3 15 Sanitizing InnoAGE SSD Sanitiz...

Страница 25: ...e for all users regardless of factors such as device and location By establishing thresholds for pertinent parameters for example temperature or the number of SSD write cycles the management system al...

Страница 26: ...ial ATA device may be either directly connected to a host or connected to a host through a cable For connection via cable the cable should be no longer than 1meter The SATA interface has a separate co...

Страница 27: ...series SMART data attributes are listed in following table Table 13 SMART attribute Attribute ID hex Value Raw Attribute Value Rsv Attribute Name 01 X Read Error Rate 05 X LSB MSB 00 00 00 00 00 Late...

Страница 28: ...8 V1 2 TPS July 2020 E5 ID 0 ID 1 ID 2 ID 3 ID 4 ID 5 Flash ID EB MSB LSB MSB LSB MSB LSB Later bad block info Read Write Erase F1 00 LSB MSB 00 00 00 Total LBA written LBA 32MB F2 00 LSB MSB 00 00 00...

Страница 29: ...nd 5th Form Factor Code 14th Operation Temperature TM28 InnoAGE M 2 Type 2280 D2 B M C Standard Grade 0 70 W Industrial Grade 40 85 Code 7th 9th Capacity Code 15th Internal control 64G 64GB 1 Equipped...

Страница 30: ...InnoAGETM M 2 S80 3TI7 30 V1 2 TPS July 2020 7 Appendix REACH...

Страница 31: ...InnoAGETM M 2 S80 3TI7 31 V1 2 TPS July 2020 RoHS...

Страница 32: ...InnoAGETM M 2 S80 3TI7 32 V1 2 TPS July 2020 MSL...

Страница 33: ...InnoAGETM M 2 S80 3TI7 33 V1 2 TPS July 2020 CE...

Страница 34: ...InnoAGETM M 2 S80 3TI7 34 V1 2 TPS July 2020 FCC...

Отзывы: