2.5” SATA SSD 3TR6-P
22
V1.8 TPS, Aug., 2022
-Protocol: Non Data Command
-Inputs
Execute AFFSI 5020 command for inputs information
Register
7
6
5
4
3
2
1
0
Features
22h
Sector Count
41h
LBA Low
Na
LBA Mid
Na
LBA High
Na
Device
1
1
1
0
Na
Command
82h
-Normal Outputs
AFFSI 5020 command for normal output information
Register
7
6
5
4
3
2
1
0
Error
Na
Sector Count
Na
LBA Low
Na
LBA Mid
Na
LBA High
Na
Device
obs
Na
obs
DEV
Na
Na
Na
Na
Status
BSY
DRDY DF
Na
DRQ
Na
Na
ERR
Device register-
DEV shall specify the selected device.
Status register
BSY will be cleared to zero indicating command completion
DRDY will be set to one.
DF (Device Fault) will be cleared to zero.
DRQ will be cleared to zero
ERR will be cleared to zero.
2. DoD 5220.22-M
This function is compliant with DoD 5220.22-M specification.
Steps:
1. The whole disk is filled with fixed character pattern 0x55.