![Inline IN2118 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/inline/in2118/in2118_operation-manual_2061974011.webp)
9
©2001 - Inline, Inc. IN2118 Operation Manual - Preliminary 01/31/01
MAXIMUM BEARING LOAD
In applications where the unit will be raised and lowered by hand or through the contact closure
control port, the maximum weight of the cover surface material affixed to the top of the interface
(the lid) should not exceed 10 pounds / 4.5 kilograms.
The maximum load bearing on the motor is 30 pounds, but exceeding the
10 pound / 4.5 kilogram load limit will shorten the life of the motor and
may compress the activation spring, preventing the unit from operating
properly..
CONNECTING THE INTERFACE
This section offers step-by-step instructions for connecting the IN2118 Interface. A Connectors
and Controls Diagram is included on page 12, and an Application Diagram is on page 13.
CAUTION: Installation of the IN2118 Interface must only be carried out by qualified techni-
cians. Before making any connections, make sure that there is no power connected to the unit.
1. Run the video coax cable(s), power cable, remote cable, and optional accessory cables
(audio / video / phone / data / control cables) to the interface.
Warning: All internal cables and connectors are pre-terminated at the
factory. Removing the connector plate may damage internal components
and will void all warranties. If you have any questions, please call INLINE
technical support at (714) 921-4100.
2. Terminate any Audio, Video and Control Cables to the backside of the A/V Connector
Modules as required by your installation (a complete list of available modules is provided
on pages 17 & 18).
Note: The IN2118 provides a Flexible Cable Conduit to ensure that the accessory cables are
not pinched or damaged while the unit ascends / descends. Before making any terminations,
run all the accessory cables through the bottom of the conduit to the A/V connector plate
opening(s).
3. Using the IN9334 3/32” Allen Wrench (included) - attach the modular connector(s) to
the IN2118 faceplate, making sure that none of the cables are pinched or damaged
(faceplate diagrams are provided on page 14). Once the connectors are securely installed,
tighten the Cable Strain Relief Clamps.
Note: All optional A/C convenience outlet(s) are pre-terminated at the factory.
4. Connect the Video Coax Cable to the (5) BNC female connectors using three, four, or
five high-resolution BNC cables, or a multi-conductor RGBHV, RGBS or RGB "snake.”
The IN7000 / IN7200 / IN7300 and IN7400P Series high-resolution cables are well suited
for this purpose. Take care while making connections to insure that the red output is
connected to the red input, green output to the green input, etc. For dual interface
applications, a second set of BNC connectors is provided.
Содержание IN2118
Страница 10: ...8 IN2118 Operation Manual Preliminary 02 05 01 2001 Inline Inc 120 230VAC 10A 60 50HZ ...
Страница 14: ...12 IN2118 Operation Manual Preliminary 01 31 01 2001 Inline Inc ...
Страница 15: ...13 2001 Inline Inc IN2118 Operation Manual Preliminary 01 31 01 ...
Страница 16: ...14 IN2118 Operation Manual Preliminary 01 31 01 2001 Inline Inc ...
Страница 24: ...22 IN2118 Operation Manual Preliminary 01 31 01 2001 Inline Inc 0 625 ...
Страница 25: ...23 2001 Inline Inc IN2118 Operation Manual Preliminary 01 31 01 ...
Страница 26: ...24 IN2118 Operation Manual Preliminary 01 31 01 2001 Inline Inc BOTTOM VIEW ...