12
IN2013 OPERATION MANUAL - REV 1.1 12/11/99
©1995 - INLINE, INC.
SW2 - Monitor Emulation Switches Factory Default Settings: 0000000000
These dip switches are normally exposed. Setting a switch to ON (1) grounds a specific pin on
the input connector for purposes of monitor emulation. Setting a switch to OFF (1) passes the
pin through the IN2013. If you don’t know what to do, set all dip switches to 0. See pages 7 & 8
for detailed instructions.
Switch Number
Function When Set to ON (1)
1
Ground Pin 9
2
Ground Pin 2
3
Ground Pin 3
4
Ground Pin 4
5
Ground Pin 5
6
Ground Pin 6
7
Ground Pin 7
8
Ground Pin 8
9
Ground Pin 1
10
N/C
SW3 - Input Computer Select
Factory Default Settings: 1111111000
Switches 8, 9 & 10 on SW3 determine where the interface looks for sync on the input connector
and what types of input sync it can accept. The factory default setting works with most Sun and
SGI workstations. These dip switches are exposed through a window in the bottom case of the
interface. For a detailed setting chart see page 4.
Important Note: #1 - #7 are normally covered because they must be left in the ON position. If
any of these switches is set to OFF the interface will not pass through any sync.
Dip 8/9/10
Input Sync Format / Location
Computers
000
RGBS - Composite Sync on pin 5
Sun SPARC
(this mode also works with RGsB signals)
101
RGBHV - H. Sync on pin 6 / V. Sync on pin 2
Sun SPARC
001
RGsB only - ignores all other sync signals
NeXT / SGI
011
RGBS - Composite Sync on pin 3
SGI
100
RGBHV - H. Sync on pin 4 / V. Sync on pin 5
SGI
010
RGBHV - H. Sync on pin 5 / V. Sync on pin 9
IBM PowerPC